Electrical Specifications
Key Features:
• 40W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
• Dual Outputs
Input Voltage Range
• Universal 90-264 AC Input
Input Frequency
Input Filter
Input Current
• EN 60950 Approved (UL)
• Compact 2 x 4 In Package
• Wide Operating Temp Range
• Meets EN 55022 B
• >200 kHour MTBF
Conditions
Min.
Typ.
Max.
90
264
127
373
47
63
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
29.0
Cold Start, 230 VAC
50.0
264 VAC
3.5
Universal
Inrush Current
Safety Ground Leakage Current
Units
VAC
VDC
Hz
A Pk
mA
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance, See Note 1
Line Regulation, See Note 2
Load Regulation, See Note 3
Ripple & Noise (20 MHz), See Note 4
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
Output 1
±3.0
Output 2
±5.0
Output 1
±1.0
Output 2
±2.0
Output 1
±3.0
Output 2
±4.0
See Model Selection Guide
115 VAC
8
230 VAC
20
±0.05
Continuous (Autorecovery)
130
See Note 3
150
Max.
Conditions
Input to Output
500 VDC
Max.
Units
%
%
%
mSec
%/°C
%
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI/RFI
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
EMC Compliance
Switching Frequency
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
3,000
Typ.
Units
VAC
1,000
M⍀
2,200
pF
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
66
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Conditions
Min.
Typ.
Max.
0
+25
+45
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
93
Ambient
Units
°C
°C
%
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)
5.99 Oz (0.170 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
200
kHours
UL 60950, EN 60950
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Current (A)
No.
115 VAC 230 VAC
MPO-40D-0512
0.75
0.46
MPO-40D-0524
0.75
0.46
1
2
1
2
Current (A)
Voltage
(VDC)
+5.0
+12.0
+5.0
+24.0
Notes:
1. Output voltage tolerance is measured at nominal input and 60%
load.
2. Line regulation is measured at nominal load over a range of 100
to 240 VAC.
3. Load regulation is specified for a load change of 60% ±40% (of
full load).
4. Output ripple is measured at 20 MHz bandwidth using 0.1 µF
and 10 µF capacitors connected in parallel as close to the power
supply terminals as possible.
5. The maximum output current is given for each individual output.
The maximum output power rating for the unit should not be
exceeded. By adding 30 CFM of airflow (see derating curves) all
models may be used at higher power levels. Contact the factory
for more information.
6. Each unit includes an input fuse (250V/2A). Since this fuse is not
field replaceable, it is recommended that an external fuse of the
same size be used on the input of the power supply for protection.
Rated
Min.
Max.
3.2
2.0
3.2
1.0
0.4
0.2
0.4
0.2
5.0
2.5
5.0
1.5
Max
Output
Power
Output
Ripple
& Noise
Max
Output
Cap.
(W)
(mV P-P)
(µF)
40
±1%
1,400
77
40
±1%
1,400
78
Efficiency
(%, Typ)
Derating Curve
Mechanical Dimensions
Connections
Input Connector (CN1):
• Molex 5273-03A or equivalent (one pin removed)
• Mating Housing: Molex 5195-03 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
1
2
3
Function
AC-Neutral
Removed
AC-Line
Safety Ground:
The mounting holes marked “Use metal standoffs” should be
connected to the system earth ground via metal spacers or
a cable. The input side mounting hole marked “FG” provides
the safety earth ground for the unit. This connection should
be locked to prevent possible loosening. Connecting the
output side mounting hole improves EMI.
Output Connector (CN2):
• Molex 5273-06A or equivalent
• Mating Housing: Molex 5195-06 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
1
2
3
4
5
6
MicroPower Direct
Function
VOUT 2
VOUT 1
VOUT 1
Common
Common
No Connection
Notes: