MPO-40D Series Dual Output, 40W Compact, Open Frame AC/DC Power Supplies Electrical Specifications Key Features: • 40W Output Power Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter • Dual Outputs Input Voltage Range • Universal 90-264 AC Input Input Frequency Input Filter Input Current • EN 60950 Approved (UL) • Compact 2 x 4 In Package • Wide Operating Temp Range • Meets EN 55022 B • >200 kHour MTBF Conditions Min. Typ. Max. 90 264 127 373 47 63 Meets EN 55022 Class B; FCC Class B See Model Selection Guide Cold Start, 115 VAC 29.0 Cold Start, 230 VAC 50.0 264 VAC 3.5 Universal Inrush Current Safety Ground Leakage Current Units VAC VDC Hz A Pk mA Output Parameter Output Voltage/Current Output Voltage Tolerance, See Note 1 Line Regulation, See Note 2 Load Regulation, See Note 3 Ripple & Noise (20 MHz), See Note 4 Hold-Up Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection Conditions Min. Typ. See Model Selection Guide Output 1 ±3.0 Output 2 ±5.0 Output 1 ±1.0 Output 2 ±2.0 Output 1 ±3.0 Output 2 ±4.0 See Model Selection Guide 115 VAC 8 230 VAC 20 ±0.05 Continuous (Autorecovery) 130 See Note 3 150 Max. Conditions Input to Output 500 VDC Max. Units % % % mSec %/°C % % General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance EMI/RFI Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Fixed EMC Compliance Switching Frequency MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Min. 3,000 Typ. Units VAC 1,000 M⍀ 2,200 pF EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 66 kHz Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Size Weight Conditions Min. Typ. Max. 0 +25 +45 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 93 Ambient Units °C °C % 4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm) 5.99 Oz (0.170 kg) Reliability Specifications Parameter MTBF Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 200 kHours UL 60950, EN 60950 Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Input Model Number Output Current (A) No. 115 VAC 230 VAC MPO-40D-0512 0.75 0.46 MPO-40D-0524 0.75 0.46 1 2 1 2 Current (A) Voltage (VDC) +5.0 +12.0 +5.0 +24.0 Notes: 1. Output voltage tolerance is measured at nominal input and 60% load. 2. Line regulation is measured at nominal load over a range of 100 to 240 VAC. 3. Load regulation is specified for a load change of 60% ±40% (of full load). 4. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µF capacitors connected in parallel as close to the power supply terminals as possible. 5. The maximum output current is given for each individual output. The maximum output power rating for the unit should not be exceeded. By adding 30 CFM of airflow (see derating curves) all models may be used at higher power levels. Contact the factory for more information. 6. Each unit includes an input fuse (250V/2A). Since this fuse is not field replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Rated Min. Max. 3.2 2.0 3.2 1.0 0.4 0.2 0.4 0.2 5.0 2.5 5.0 1.5 Max Output Power Output Ripple & Noise Max Output Cap. (W) (mV P-P) (µF) 40 ±1% 1,400 77 40 ±1% 1,400 78 Efficiency (%, Typ) Derating Curve Mechanical Dimensions Connections Input Connector (CN1): • Molex 5273-03A or equivalent (one pin removed) • Mating Housing: Molex 5195-03 or equivalent • Mating Terminal: Molex 5293 or equivalent Pin 1 2 3 Function AC-Neutral Removed AC-Line Safety Ground: The mounting holes marked “Use metal standoffs” should be connected to the system earth ground via metal spacers or a cable. The input side mounting hole marked “FG” provides the safety earth ground for the unit. This connection should be locked to prevent possible loosening. Connecting the output side mounting hole improves EMI. Output Connector (CN2): • Molex 5273-06A or equivalent • Mating Housing: Molex 5195-06 or equivalent • Mating Terminal: Molex 5293 or equivalent Pin 1 2 3 4 5 6 MicroPower Direct Function VOUT 2 VOUT 1 VOUT 1 Common Common No Connection Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]