Emerson Network Power NPS63-M 90 - 264 vac (wide range) 127-300 vdc Datasheet

Embedded Power for
Business-Critical Continuity
Rev.03.21.13_185
NPS60-M Series
1 of 3
NPS60-M Series
60 Watts
Total Power:
Input Voltage:
# of Outputs:
60 Watts
90 - 264 VAC
127 - 300 VDC
Single
Special Features
• Medical and ITE Safety Approvals
• Universal input
• Less than 1U high
• 2” x 4” footprint
• Remote sense
• Overload and short circuit
protection
• Adjustable output voltage
• High efficiency
• High MTBF
• Built in EMI filter
(CISPR 22 Class B)
• International Efficiency Level V,
Energy Star 2.0 & CeC compliant
(except NPS62-M)
• Less than 300 mW no-load
power consumption
• 0˚C to +80˚C operation
• Input power < 74 watts
• Complies with EN61000 -3-2
• UL Class I approved
• Class II approved (with Class A
EMI)
• LPX50 enclosure kit available
• Dual AC fuses
Safety
• TUV: 60950, 60601-1
• UL:
60950, 60601-1
• CSA: 60950, 60601-1
• NEMKO: 60950, 60601-1
• CB:
Certificate and report
• CE:
Mark (LVD)
• CCC: Mark
Electrical Specifications
Input
Input ra­nge:
90 - 264 VAC (wide range) 127-300 Vdc
Frequency:
47 - 63 Hz
Inrush current:
< 50 A peak @ 230 VAC, cold start @ 25° C
Input power:
< 74 Watts
Efficiency:
EMI/RFI:
87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%)
Safety ground leakage
current:
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted, VDE0878PT3 Class B conducted
275uA @ 50/60 Hz; 264 VAC input
Output
Maximum power:
Adjustment range:
60 W for convection
± 20% minimum
Hold-up time:
Overload protection:
10/20 ms 115/230 VAC input line
Short circuit protection on all outputs. Case overload protected @
110-180% of normal rating
Overvoltage protection: 30-50% above nominal output
Remote sense:
Compensated for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev.03.21.13_185
NPS60-M Series
2 of 3
Environmental Specifications
Operating temperature:
Storage temperature:
Electromagnetic susceptibility:
0° to 50 °C ambient derate each output at 2.5% per degree from 50° to 80 °C. -20 °C start up
-45 °C to +85 °C
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity:
Operating; non-condensing 10% to 90% RH
Vibration:
IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated:
> 550,000 hours at full load and 25 °C ambient conditions
Mechanical Drawing
BARCODE
SERIAL LABEL
M1
GND TAB
(CN1)
SK2
SK1
1.72"
(43.8)
PIN 1
PIN 1
PIN 6
PIN 3
INPUT
CONNECTOR
(SK1)
MODEL LABEL
ROHS LABEL
M2
6 PIN OUTPUT
CONNECTOR
(SK2)
1.26"
(32.1)
0.16” (4.0) MOUNTING HOLE
(4 PLACES)
2.00"
(50.8)
VR1
OUTPUT VOLTAGE
ADJUST POT
4.00"
(101.6) 3.73"
(94.6)
0.197” (5.0) MINIMUM STANDOFF HEIGHT
1.12"
(28.5)
Embedded Power for
Business-Critical Continuity
Ordering Information
­Americas
Rev.03.21.13_185
NPS60-M Series
3 of 3
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Peak
Load1
Regulation
Ripple P/P
(PARD)3
NPS62-M
5V
0A
11 A
13 A
± 2%
50 mV
NPS63-M
12 V
0A
5A
5.5 A
± 2%
120 mV
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
NPS64-M
15 V
0A
4A
4.4 A
± 2%
150 mV
Europe (UK)
NPS65-M
24 V
0A
2.5 A
2.75 A
± 2%
240 mV
2
1. Peak current lasting < 15 seconds with a maximum 10% duty cycle.
2­. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3­. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and
load ranges.
Asia (HK)
Pin Assignments
Connector
SK1-1
SK1-3
CN1
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
NPS62-M
NPS63-M
NPS64-M
NPS65-M
Line
Neutral
Ground
+5 V
+5 V
Common
Common
-Sense
+Sense
Line
Neutral
Ground
+12 V
+12 V
Common
Common
-Sense
+Sense
Line
Neutral
Ground
+15 V
+15 V
Common
Common
-Sense
+Sense
Line
Neutral
Ground
+24 V
+24 V
Common
Common
-Sense
+Sense
Mating­ Connectors
AC Input:
Molex 09-50-8031 (USA)
09-93-0300 (UK)
PINS: 08-52-0113
DC Outputs: Molex 09-50-8061 (USA)
09-93-0600 (UK)
PINS: 08-52-0113
Emerson Network Power Connector Kit #70-841-006, includes all of the above
Notes:
1. Specifications subject to change without notice
­2. All dimensions in inches (mm), tolerance is ±0.02”­­ (±0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes
4. Mounting hole M1 is safety ground connection
5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise
stated
6. For DC input an external DC safety rated fuse must be used
7. Warranty: 2 year
8. Weight: 0.26lbs/0.118kg
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson and the Emerson Network Power
logo are trademarks of Emerson Electric Co.
©2012 Emerson Electric Co.
All rights reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Emerson Network Power:
NPS64-M
Similar pages