EPCOS B32796G4136+000 Metallized polypropylene film capacitors (mkp) Datasheet

Film Capacitors
Metallized Polypropylene Film Capacitors (MKP)
Series/Type:
B32794 ... B32798
Date:
October 2011
© EPCOS AG 2011. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Metallized polypropylene film capacitors (MKP)
B32794 ... B32798
MKP AC filtering
Typical applications
Output AC filtering for power converters
UPS, solar inverters, motor drives
Dimensional drawings
2-pin version
Climatic
Max. operating temperature: 105 °C
Climatic category (IEC 60068-1): 40/85/56
Construction
Dielectric: Polypropylene (PP)
Plastic case (UL 94 V-0)
Epoxy resin sealing (UL 94 V-0)
Features
Optimized AC voltage performance
High ripple current/frequency capability
Small dimensions
For PCB mounting
4-pin version
Terminals
Parallel wire leads, lead-free tinned
2-pin and 4-pin versions
Standard lead lengths: 6 1 mm
Special lead lengths available on request
Marking
Manufacturer's logo, date code,
rated capacitance (coded), capacitance
tolerance (code letter), rated AC voltage
Dimensions in mm
Version
Lead
spacing
±0.4
Lead
diameter
d1
Type
2-pin
27.5
0.8
B32794D
2-pin
37.5
1.0
B32796E/T
4-pin
37.5
1.2
B32796G
4-pin
52.5
1.2
B32798G
Delivery mode
Bulk (untaped, lead length 6 1 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 19
B32794 ... B32798
MKP AC filtering
Overview of available types
Lead spacing 27.5 mm
Type
B32794
Page
6
VRMS (V AC)
250
300
350
CR (µF)
0.82
1.2
1.5
2.0
2.2
2.5
3.3
3.5
4.0
5.0
6.3
7.5
8.0
10
12
15
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 19
400
B32794 ... B32798
MKP AC filtering
Lead spacing 37.5 mm
Type
B32796
Page
7
VRMS (V AC)
250
300
350
CR (µF)
2.7
3.5
4.0
5.0
5.6
7.5
8.0
10
11
13
14
15
16
20
22
24
25
30
34
40
45
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 19
400
B32794 ... B32798
MKP AC filtering
Lead spacing 52.5 mm
Type
B32798
Page
9
VRMS (V AC)
250
300
350
CR (µF)
18
20
25
26
30
35
40
55
75
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 19
400
B32794
MKP AC filtering
Ordering codes and packing units (lead spacing 27.5 mm)
VRMS VR
Max. dimensions
w×h×l
P1
V AC V DC µF
mm
mm
250
11.0 × 19.0 × 31.5
11.0 × 21.0 × 31.5
15.0 × 24.5 × 31.5
16.0 × 32.0 × 31.5
22.0 × 36.5 × 31.5
11.0 × 19.0 × 31.5
13.5 × 23.0 × 31.5
14.0 × 24.5 × 31.5
18.0 × 33.0 × 31.5
22.0 × 36.5 × 31.5
11.0 × 19.0 × 31.5
12.5 × 21.5 × 31.5
15.0 × 24.5 × 31.5
18.0 × 33.0 × 31.5
22.0 × 36.5 × 31.5
11.0 × 19.0 × 31.5
13.5 × 23.0 × 31.5
14.0 × 24.5 × 31.5
18.0 × 33.0 × 31.5
22.0 × 36.5 × 31.5
300
350
400
630
CR
2.5
4.0
6.3
10
15
700 2.0
3.3
5.0
8.0
12
875 1.2
2.2
3.3
5.0
7.5
1050 0.82
1.5
2.2
3.5
5.0
Ordering code
(composition see
below)
B32794D2255+000
B32794D2405+000
B32794D2635+000
B32794D2106+000
B32794D2156+000
B32794D3205+000
B32794D3335+000
B32794D3505+000
B32794D3805+000
B32794D3126+000
B32794D8125+000
B32794D8225+000
B32794D8335+000
B32794D8505+000
B32794D8755+000
B32794D4824+000
B32794D4155+000
B32794D4225+000
B32794D4355+000
B32794D4505+000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series and intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 19
IRMS
ESL ESR Untaped
60 °C
10 kHz
10 kHz
pcs./
A
nH mΩ
MOQ
4
24 14.1 2352
6
25
9.1 2352
8
26
6.1 1680
11
27
4.2 1064
13
28
3.1
784
4
24 15.6 2352
6
25
9.7 1932
7
26
6.7 1848
9
27
4.6
952
11
28
3.5
784
3
24 21.2 2352
5
25 11.9 2100
7
26
8.2 1680
9
27
5.8
952
12
28
4.5
784
3
24 26.5 2352
4
25 14.8 1932
6
26 10.4 1848
8
27
6.9
952
11
28
5.5
784
B32796
MKP AC filtering
Ordering codes and packing units (lead spacing 37.5 mm)
VRMS VR
Max. dimensions
w×h×l
P1
V AC V DC µF
mm
mm
250
24.0 × 15.0 × 41.5
24.0 × 19.0 × 41.5
20.0 × 39.5 × 42.0
20.0 × 39.5 × 42.0
28.0 × 37.0 × 42.0
28.0 × 37.0 × 42.0
30.0 × 45.0 × 42.0
30.0 × 45.0 × 42.0
33.0 × 48.0 × 42.5
24.0 × 15.0 × 41.5
24.0 × 19.0 × 41.5
20.0 × 39.5 × 42.0
20.0 × 39.5 × 42.0
28.0 × 37.0 × 42.0
28.0 × 37.0 × 42.0
30.0 × 45.0 × 42.0
30.0 × 45.0 × 42.0
33.0 × 48.0 × 42.5
24.0 × 15.0 × 41.5
24.0 × 19.0 × 41.5
20.0 × 39.5 × 42.0
20.0 × 39.5 × 42.0
28.0 × 37.0 × 42.0
28.0 × 37.0 × 42.0
30.0 × 45.0 × 42.0
30.0 × 45.0 × 42.0
30.0 × 45.0 × 42.0
33.0 × 48.0 × 42.5
10.2
10.2
20.3
20.3
10.2
10.2
20.3
20.3
10.2
10.2
20.3
20.3
20.3
300
350
630
CR
8
11
22
22
25
25
40
40
45
700 5.6
7.5
16
16
20
20
30
30
34
875 4
5
10
10
14
14
15
20
20
24
Ordering code
(composition see
below)
B32796T2805+000
B32796T2116+000
B32796G2226+000
B32796E2226+000
B32796G2256+000
B32796E2256+000
B32796G2406+000
B32796E2406+000
B32796G2456+000
B32796T3565+000
B32796T3755+000
B32796G3166+000
B32796E3166+000
B32796G3206+000
B32796E3206+000
B32796G3306+000
B32796E3306+000
B32796E3346+000
B32796T8405+000
B32796T8505+000
B32796G8106+000
B32796E8106+000
B32796G8146+000
B32796E8146+000
B32796G8156+000
B32796G8206+000
B32796E8206+000
B32796G8246+000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series and intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 19
IRMS
ESL ESR Untaped
60 °C
10 kHz
10 kHz
pcs./
A
nH mΩ
MOQ
8
21
9
1040
10
23
8
780
15
30
3.2
640
14
30
3.2
640
17
30
2.9
440
16
30
2.9
440
21
33
2.3
400
20
33
2.3
400
23
33
1.9
180
7
21 12
1040
9
23 10
780
14
30
3.9
640
13
30
3.9
640
15
30
3.1
440
14
30
3.1
440
19
33
2.2
400
18
33
2.2
400
20
33
1.9
180
7
21 13
1040
9
23 11
780
12
30
4.9
640
11
30
4.9
640
15
30
3.6
440
14
30
3.6
440
15
30
3.0
400
19
30
2.6
400
18
30
2.6
400
20
30
2.5
180
B32796
MKP AC filtering
Ordering codes and packing units (lead spacing 37.5 mm)
VRMS VR
Max. dimensions
w×h×l
P1
V AC V DC µF
mm
mm
400
24.0 × 15.0 × 41.5
24.0 × 19.0 × 41.5
20.0 × 39.5 × 42.0
20.0 × 39.5 × 42.0
28.0 × 37.0 × 42.0
28.0 × 37.0 × 42.0
30.0 × 45.0 × 42.0
30.0 × 45.0 × 42.0
33.0 × 48.0 × 42.5
10.2
10.2
20.3
20.3
1050
CR
2.7
3.5
7.5
7.5
10
10
13
13
16
Ordering code
(composition see
below)
B32796T4275+000
B32796T4355+000
B32796G4755+000
B32796E4755+000
B32796G4106+000
B32796E4106+000
B32796G4136+000
B32796E4136+000
B32796G4166+000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series and intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 19
IRMS
ESL ESR Untaped
60 °C
10 kHz
10 kHz
pcs./
A
nH mΩ
MOQ
7
21 15
1040
8
23 13
780
11
30
5.5
640
10
30
5.5
640
14
30
4.5
440
13
30
4.5
440
17
33
3.5
400
16
33
3.5
400
18
33
3.5
180
B32798
MKP AC filtering
Ordering codes and packing units (lead spacing 52.5 mm)
VRMS VR
Max. dimensions
w×h×l
P1
V AC V DC µF
mm
mm
250
30.0 × 45.0 × 57.5
35.0 × 50.0 × 57.5
30.0 × 45.0 × 57.5
35.0 × 50.0 × 57.5
30.0 × 45.0 × 57.5
35.0 × 50.0 × 57.5
35.0 × 50.0 × 57.5
35.0 × 50.0 × 57.5
30.0 × 45.0 × 57.5
35.0 × 50.0 × 57.5
35.0 × 50.0 × 57.5
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
20.3
300
350
400
CR
630 55
75
700 40
55
875 26
30
35
40
1050 18
20
25
Ordering code
(composition see
below)
B32798G2556+000
B32798G2756+000
B32798G3406+000
B32798G3556+000
B32798G8266+000
B32798G8306+000
B32798G8356+000
B32798G8406K000
B32798G4186+000
B32798G4206+000
B32798G4256+000
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series and intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code:
K = ±10%
J = ±5%
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 19
IRMS
ESL ESR Untaped
60 °C
10 kHz
10 kHz
pcs./
A
nH mΩ
MOQ
21
35 2.7
280
25
38 2.1
108
19
35 3.2
280
24
38 2.5
108
18
35 4.5
280
20
37 4.0
108
22
38 3.0
108
22
38 3.0
108
16
35 4.7
280
17
37 4.5
108
20
38 3.5
108
B32794 ... B32798
MKP AC filtering
Technical data
Reference standard: IEC 61071, EN 61071, VDE 0560-120
Max. operating temperature, Top,max +105 °C
Operating temperature range (case)
Upper category temperature Tmax
+85 °C
Lower category temperature Tmin
–40 °C
Note: At T > 85 °C de-rating for
VRMS (V AC) should be 1.5%/°C
Capacitance drift in range
2% respect the value measured at reference conditions
(40 °C, 85 °C)
Insulation Resistance Rins
30 000 s
given as time constant
τ = CR Rins, rel. humidity ≤ 65%
(minimum as-delivered values)
Test voltage between terminals
1.5 VR for 10 s
1.65 VR for 2 s
DC test voltage terminal to case (10 s)
2 VRMS + 1000 V AC (min. 2000 V AC) at 50 Hz
Maximum permissible overvoltage for
1.3 VRMS
short operating periods (max 1 min/day)
Maximum peak current (A)
Damp heat test
Limit values after damp heat test
56 days/40 °C/93% relative humidity
Capacitance change | ∆C/C |
≤ 5%
Dissipation factor change ∆ tan δ ≤ 1.5 · 10-3 (at 1 kHz)
≥ 50% of minimum
Insulation resistance Rins
as-delivered values
Change of temperature
Reliability:
Failure rate λ
In accordance with IEC 60068-2-14 (Test Nb)
300 fit
Service life tSL
Failure criteria:
Total failure
Failure due to
variation of
parameters
Please read Cautions and warnings and
Important notes at the end of this document.
> 60 000 h at VRMS
For conversion to other operating conditions, refer to
chapter "Reliability" on page 439 from Data Book 2009.
Short/open circuit
Capacitance change | ∆C/C |
≥ 10%
Dissipation factor change ∆ tan δ > 4 · upper limit value
Insulation resistance Rins
< 1500 MΩ
(CR≤0.33µF)
or time constant τ = CR · Rins
< 500 s (CR>0.33µF)
Page 10 of 19
B32794 ... B32798
MKP AC filtering
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
Note:
The values of dV/dt provided below must not be exceeded in order to avoid damaging the
capacitor.
Lead spacing
27.5 mm
37.5 mm
52.5 mm
Type
B32794
B32796
B32798
VRMS (V AC)
250
300
350
400
250
300
350
400
250
300
350
400
26
32
12
14
18
21
dV/dt in V/µs
27
31
39
47
19
21
Notes: Please take all additional data not mentioned above from our Data Book 2009
Mounting guidelines
1
Soldering
1.1
Solderability of leads
The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1.
Before a solderability test is carried out, terminals are subjected to accelerated ageing (to
IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far
higher than the upper category temperature of the capacitors, the terminal wires should be cut off
from the capacitor before the ageing procedure to prevent the solderability being impaired by the
products of any capacitor decomposition that might occur.
Solder bath temperature
235 ±5 °C
Soldering time
2.0 ±0.5 s
Immersion depth
2.0 +0/0.5 mm from capacitor body or seating plane
Evaluation criteria:
Visual inspection
Wetting of wire surface by new solder ≥90%, free-flowing solder
1.2
Resistance to soldering heat
Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A.
Conditions:
Series
Please read Cautions and warnings and
Important notes at the end of this document.
Solder bath temperature Soldering time
Page 11 of 19
B32794 ... B32798
MKP AC filtering
MKT boxed (except 2.5 × 6.5 × 7.2 mm) 260 ±5 °C
coated
uncoated (lead spacing > 10 mm)
MFP
MKP (lead spacing > 7.5 mm)
MKT boxed (case 2.5 × 6.5 × 7.2 mm)
MKP (lead spacing ≤ 7.5 mm)
MKT uncoated (lead spacing ≤ 10 mm)
insulated (B32559)
10 ±1 s
5 ±1 s
<4s
recommended soldering
profile for MKT uncoated
(lead spacing ≤ 10 mm) and
insulated (B32559)
Immersion depth
2.0 +0/0.5 mm from capacitor body or seating plane
Shield
Heat-absorbing board, (1.5 ±0.5) mm thick, between capacitor
body and liquid solder
Evaluation criteria:
Visual inspection
∆C/C0
tan δ
Please read Cautions and warnings and
Important notes at the end of this document.
No visible damage
2% for MKT/MKP/MFP
5% for EMI suppression capacitors
As specified in sectional specification
Page 12 of 19
B32794 ... B32798
MKP AC filtering
1.3
General notes on soldering
Permissible heat exposure loads on film capacitors are primarily characterized by the upper category temperature Tmax. Long exposure to temperatures above this type-related temperature limit
can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical
characteristics. For short exposures (as in practical soldering processes) the heat load (and thus
the possible effects on a capacitor) will also depend on other factors like:
Pre-heating temperature and time
Forced cooling immediately after soldering
Terminal characteristics:
diameter, length, thermal resistance, special configurations (e.g. crimping)
Height of capacitor above solder bath
Shadowing by neighboring components
Additional heating due to heat dissipation by neighboring components
Use of solder-resist coatings
The overheating associated with some of these factors can usually be reduced by suitable countermeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced
cooling process may possibly have to be included.
EPCOS recommends the following conditions:
Pre-heating with a maximum temperature of 110 °C
Temperature inside the capacitor should not exceed the following limits:
MKP/MFP 110 °C
MKT 160 °C
When SMD components are used together with leaded ones, the leaded film capacitors should
not pass into the SMD adhesive curing oven. The leaded components should be assembled after the SMD curing step.
Leaded film capacitors are not suitable for reflow soldering.
Uncoated capacitors
For uncoated MKT capacitors with lead spacings ≤10 mm (B32560/B32561) the following measures are recommended:
pre-heating to not more than 110 °C in the preheater phase
rapid cooling after soldering
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 19
B32794 ... B32798
MKP AC filtering
Cautions and warnings
Do not exceed the upper category temperature (UCT).
Do not apply any mechanical stress to the capacitor terminals.
Avoid any compressive, tensile or flexural stress.
Do not move the capacitor after it has been soldered to the PC board.
Do not pick up the PC board by the soldered capacitor.
Do not place the capacitor on a PC board whose PTH hole spacing differs from the specified
lead spacing.
Do not exceed the specified time or temperature limits during soldering.
Avoid external energy inputs, such as fire or electricity.
Avoid overload of the capacitors.
The table below summarizes the safety instructions that must always be observed. A detailed description can be found in the relevant sections of the chapters "General technical information" and
"Mounting guidelines".
Topic
Storage conditions
Flammability
Resistance to
vibration
Safety information
Reference chapter
"General technical
information"
Make sure that capacitors are stored within the
4.5
specified range of time, temperature and humidity "Storage conditions"
conditions.
Avoid external energy, such as fire or electricity
5.3
(passive flammability), avoid overload of the
"Flammability"
capacitors (active flammability) and consider the
flammability of materials.
Do not exceed the tested ability to withstand
5.2
vibration. The capacitors are tested to
"Resistance to vibration"
IEC 60068-2-6.
EPCOS offers film capacitors specially designed
for operation under more severe vibration regimes
such as those found in automotive applications.
Consult our catalog "Film Capacitors for
Automotive Electronics".
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 19
B32794 ... B32798
MKP AC filtering
Topic
Safety information
Soldering
Do not exceed the specified time or temperature
limits during soldering.
Cleaning
Use only suitable solvents for cleaning capacitors.
Embedding of
When embedding finished circuit assemblies in
capacitors in
plastic resins, chemical and thermal influences
finished assemblies must be taken into account.
Caution: Consult us first, if you also wish to
embed other uncoated component types!
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 19
Reference chapter
"Mounting guidelines"
1 "Soldering"
2 "Cleaning"
3 "Embedding of
capacitors in finished
assemblies"
B32794 ... B32798
MKP AC filtering
Symbols and terms
Symbol
α
αC
A
βC
C
CR
∆C
∆C/C
∆C/CR
dt
∆t
∆T
∆tan δ
∆V
dV/dt
∆V/∆t
E
ESL
ESR
f
f1
f2
fr
FD
FT
i
IC
English
Heat transfer coefficient
Temperature coefficient of capacitance
Capacitor surface area
Humidity coefficient of capacitance
Capacitance
Rated capacitance
Absolute capacitance change
Relative capacitance change (relative
deviation of actual value)
Capacitance tolerance (relative deviation
from rated capacitance)
Time differential
Time interval
Absolute temperature change
(self-heating)
Absolute change of dissipation factor
Absolute voltage change
Time differential of voltage function (rate
of voltage rise)
Voltage change per time interval
Activation energy for diffusion
Self-inductance
Equivalent series resistance
Frequency
Frequency limit for reducing permissible
AC voltage due to thermal limits
German
Wärmeübergangszahl
Temperaturkoeffizient der Kapazität
Kondensatoroberfläche
Feuchtekoeffizient der Kapazität
Kapazität
Nennkapazität
Absolute Kapazitätsänderung
Relative Kapazitätsänderung (relative
Abweichung vom Ist-Wert)
Kapazitätstoleranz (relative Abweichung
vom Nennwert)
Differentielle Zeit
Zeitintervall
Absolute Temperaturänderung
(Selbsterwärmung)
Absolute Änderung des Verlustfaktors
Absolute Spannungsänderung
Differentielle Spannungsänderung
(Spannungsflankensteilheit)
Spannungsänderung pro Zeitintervall
Aktivierungsenergie zur Diffusion
Eigeninduktivität
Ersatz-Serienwiderstand
Frequenz
Grenzfrequenz für thermisch bedingte
Reduzierung der zulässigen
Wechselspannung
Frequency limit for reducing permissible Grenzfrequenz für strombedingte
AC voltage due to current limit
Reduzierung der zulässigen
Wechselspannung
Resonant frequency
Resonanzfrequenz
Thermal acceleration factor for diffusion Therm. Beschleunigungsfaktor zur
Diffusion
Derating factor
Deratingfaktor
Current (peak)
Stromspitze
Category current (max. continuous
Kategoriestrom (max. Dauerstrom)
current)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 19
B32794 ... B32798
MKP AC filtering
Symbol
IRMS
iz
k0
LS
λ
λ0
λtest
Pdiss
Pgen
Q
ρ
R
R
Ri
Rins
RP
RS
S
t
T
τ
tan δ
tan δD
tan δP
tan δS
TA
Tmax
Tmin
tOL
Top
TR
Tref
tSL
VAC
English
(Sinusoidal) alternating current,
root-mean-square value
Capacitance drift
Pulse characteristic
Series inductance
Failure rate
Constant failure rate during useful
service life
Failure rate, determined by tests
Dissipated power
Generated power
Heat energy
Density of water vapor in air
Universal molar constant for gases
Ohmic resistance of discharge circuit
Internal resistance
Insulation resistance
Parallel resistance
Series resistance
severity (humidity test)
Time
Temperature
Time constant
Dissipation factor
Dielectric component of dissipation
factor
Parallel component of dissipation factor
Series component of dissipation factor
Ambient temperature
Upper category temperature
Lower category temperature
Operating life at operating temperature
and voltage
Operating temperature
Rated temperature
Reference temperature
Reference service life
AC voltage
Please read Cautions and warnings and
Important notes at the end of this document.
German
(Sinusförmiger) Wechselstrom
Inkonstanz der Kapazität
Impulskennwert
Serieninduktivität
Ausfallrate
Konstante Ausfallrate in der
Nutzungsphase
Experimentell ermittelte Ausfallrate
Abgegebene Verlustleistung
Erzeugte Verlustleistung
Wärmeenergie
Dichte von Wasserdampf in Luft
Allg. Molarkonstante für Gas
Ohmscher Widerstand des
Entladekreises
Innenwiderstand
Isolationswiderstand
Parallelwiderstand
Serienwiderstand
Schärfegrad (Feuchtetest)
Zeit
Temperatur
Zeitkonstante
Verlustfaktor
Dielektrischer Anteil des Verlustfaktors
Parallelanteil des Verlfustfaktors
Serienanteil des Verlustfaktors
Umgebungstemperatur
Obere Kategorietemperatur
Untere Kategorietemperatur
Betriebszeit bei Betriebstemperatur und
-spannung
Beriebstemperatur
Nenntemperatur
Referenztemperatur
Referenz-Lebensdauer
Wechselspannung
Page 17 of 19
B32794 ... B32798
MKP AC filtering
Symbol
VC
VC,RMS
English
Category voltage
Category AC voltage
VCD
Vch
VDC
VFB
Vi
Vo
Vop
Vp
Vpp
VR
Corona-discharge onset voltage
Charging voltage
DC voltage
Fly-back capacitor voltage
Input voltage
Output voltage
Operating voltage
Peak pulse voltage
Peak-to-peak voltage Impedance
Rated voltage
Amplitude of rated AC voltage
R
VRMS
German
Kategoriespannung
(Sinusförmige)
Kategorie-Wechselspannung
Teilentlade-Einsatzspannung
Ladespannung
Gleichspannung
Spannung (Flyback)
Eingangsspannung
Ausgangssspannung
Betriebsspannung
Impuls-Spitzenspannung
Spannungshub
Nennspannung
Amplitude der Nenn-Wechselspannung
VSC
Vsn
(Sinusoidal) alternating voltage,
root-mean-square value
S-correction voltage
Snubber capacitor voltage
Z
Impedance
Spannung bei Anwendung "S-correction"
Spannung bei Anwendung
"Beschaltung"
Scheinwiderstand
Lead spacing
Rastermaß
Please read Cautions and warnings and
Important notes at the end of this document.
(Sinusförmige) Wechselspannung
Page 18 of 19
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,
DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC,
PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap,
SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
Page 19 of 19