MORNSUN K7803-500R3 Support the negative output Datasheet

DC/DC Converter
K78xx-500R3 Series
Wide input voltage, non-isolated & regulated single
FEATURES
output
High efficiency up to 95%
No-load input current as low as 0.2mA
Operating temperature range: -40℃ to +85℃
Support the negative output
Output short circuit protection
Pin-out compatible with LM78XX linear regulators
UL60950, EN60950 approval







RoHS
K78xx-500R3 series are high efficiency switching regulators and ideal substitutes of LM78xx series three-terminal linear regulators. The product
is featured with high efficiency, low loss, short circuit protection, support the negative output and no heat sink requirement. They are widely
used in industrial control, instrumentation, and electric power applications.
Selection Guide
Certification
Part
Number
K7803-500R3
K7805-500R3
K7809-500R3
UL/CE
K7812-500R3
K7815-500R3
Input Voltage (VDC)
Nominal
(Range)
24
(4.75-36)
24
(6.5-36)
12
(7-31)
24
(12-36)
24
(15-36)
12
(8-24)
24
(19-36)
12
(8-21)
Output
Output Voltage
(VDC)
Max. Output
Current (mA)
Efficiency (%/Typ.)
(Min. Vin)/ (Max. Vin)
@Full Load
Max.
Capacitive
Load(µF)
3.3
500
86/80
680
5.0
500
90/84
680
-5.0
-300
80/81
330
9
500
93/90
680
12
500
94/91
680
-12
-150
84/85
330
15
500
95/93
680
-15
-150
85/87
330
Note:For input voltage higher than 30 VDC, a 22uF/50V input capacitor is required.
Input Specifications
Item
Operating Conditions
No-load Input Current
Positive output
Min.
Typ.
Max.
Unit
--
0.2
1.5
mA
Reverse Polarity Input
Forbidden
Input Filter
Capacitor filter
Output Specifications
Item
Operating Conditions
Output Voltage Accuracy
Full load, input voltage range
Line Regulation
Full load, input voltage range
Load Regulation
Nominal input voltage,10% -100% load
Ripple & Noise*
Temperature Coefficient
Transient response deviation
Transient recovery time
Output short circuit protection
Min.
Typ.
Max.
K7803-500R3
--
±2
±4
Others
--
±2
±3
--
±0.2
±0.4
--
±0.4
±0.6
--
20
75
mVp-p
--
--
±0.03
%/℃
--
50
250
mV
--
0.2
1
ms
20MHz bandwidth, nominal input voltage,
10% -100% load
Operating temperature -40℃ to +85℃
Nominal input voltage, 25% load step change
Nominal input voltage
Unit
%
Continuous, self-recovery
Note: *1. Ripple and noise tested with “parallel cable” method, please refer to DC-DC Converter Application Notes for specific operation methods;
*2.With the load lower than 10%, the maximum ripple and noise of 3.3V/5V output products will be 150mVp-p, 9V/12V/15V output products will be 2%Vo.
2016.11.01-A/2
Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
K78xx-500R3 Series
General Specifications
Item
Operating Temperature
Operating Conditions
Min.
see Fig. 1
-40
--
+85
-55
--
+125
Storage Temperature
Typ.
Max.
单位
℃
Pin Welding Resistance Temperature
Welding time: 10s (Max.)
--
--
+260
Storage Humidity
Non-condensing
5
--
95
Switching Frequency
Full load, nominal input voltage
550
--
850
KHz
MTBF
MIL-HDBK-217F@25℃
2000
--
--
K hours
%RH
Physical Specifications
Casing Material
Black flame-retardant and heat-resistant plastic (UL94 V-0)
Package Dimensions
11.60*7.55*10.16 mm
Weight
1.8g (Typ.)
Cooling Method
Free air convection
EMC Specifications
EMI
EMS
CE
CISPR22/EN55022
CLASS B (see Fig. 5-② for recommended circuit)
RE
CISPR22/EN55022
CLASS B (see Fig. 5-② for recommended circuit)
ESD
IEC/EN 61000-4-2
Contact ±4KV
perf. Criteria B
RS
IEC/EN 61000-4-3
10V/m
perf. Criteria A
EFT
IEC/EN 61000-4-4
±1KV (see Fig. 5-① for recommended circuit)
perf. Criteria B
Surge
IEC/EN 61000-4-5
line to line ±1KV (see Fig. 5-① for recommended circuit)
perf. Criteria B
CS
IEC/EN 61000-4-6
3Vr.m.s
perf. Criteria A
Output Power Percentage(%)
Product Characteristic Curve
120
Temperature Derating Curve
100
80
60
Safe Operating Area
40
20
0
-40
0
40
71 85
120
Operating Temperature (℃ )
Fig. 1
2016.11.01-A/2
Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
K78xx-500R3 Series
Design Reference
1. Typical application circuit
1
+Vin
C1
GND
3
DC/D C
2
1
+Vin
+Vout
C1
C2
-Vout
3
C2
GN D
GND
Positive output application circuit
2
DC / DC
GN D
Negative output application circuit
Fig. 2 Typical application circuit
+Vin
1
DC/DC
2
C3
GND
+Vout
3
C4
Sheet 1
C1/C3
C2/C4
(ceramic capacitor) (ceramic capacitor)
Part No.
GND
K7803-500R3
LDM
1
DC/DC
-Vout
2
22μF/10V
K7809-500R3
3
C1
22μF/10V
K7805-500R3
C2
10μF/50V
22μF/16V
K7812-500R3
22μF/25V
K7815-500R3
22μF/25V
Fig. 3 Positive and Negative output parallelling application circuit
Note:
1. C1 and C2 (C3 and C4) are required and should be connected close to the pin terminal of the module.
2. The capacitance of C1 and C2 (C3 and C4) refer to Sheet 1, it can be increased properly if required, and tantalum or low ESR electrolytic capacitors may
also suffice.
3. When the products used as the circuit like figure 3, an inductor named as LDM up to 10μH is recommended in the circuit to reduce the mutual interference.
4. Cannot be used in parallel for output and hot swap.
To reduce the output ripple furtherly, it is suggested to connect a “LC” filter at the output terminal, and recommended value of L is
10µH-47µH.
+Vin
1
C1
DC/DC
L
Vout
3
2
+Vin
C2
负
载
22μ F
1
DC/DC
2
3
C1
L
Vout
C2
22μ F
负
载
GND
GND
Negative output
Positive output
Fig. 4 “LC” filter application circuit
2. EMC solution-recommended circuit
FUSE
L DM 1
L DM 2
V in
Vin
C0
+Vo
GN D
+
M OV
DC/DC
C1
C5
C2
L OAD
GN D
①
②
Fig. 5 EMC recommended circuit
2016.11.01-A/2
Page 3 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
K78xx-500R3 Series
FUSE
Selected based on the actual
input current from the customer
MOV
LDM1
C0
C1/C2
C5
LDM2
S20K30
82µH
680µF /50V
Refer to Sheet 1
4.7µF /50V
12µH
Note: Part ① in the Fig. 5 is for EMS test, part ② is for EMI filtering; parts ① and ② can be added based on actual requirement.
3. For more information please find the application notes on www.mornsun-power.com
Dimensions and Recommended Layout
Notes:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing
bag number:58200003;
2. The max. capacitive load should be tested within the input voltage range and under full load conditions;
3. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25℃, humidity<75%RH when inputting
nominal voltage and outputting rated load;
4. All index testing methods in this datasheet are based on our Company’s corporate standards;
5. The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact with our technician for specific information;
6. Specifications of this product are subject to changes without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2016.11.01-A/2
Page 4 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages