HP HEDS-5700-E01 Panel mount optical encoder Datasheet

H
Panel Mount Optical Encoders
Technical Data
HEDS-5700 Series
Features
• Two Channel Quadrature
Output with Optional Index
Pulse
• Available with or without
Static Drag for Manual or
Mechanized Operation
• High Resolution – Up to
512 CPR
• Long Rotational Life,
>1 Million Revolutions
• -20 to 85°C Operating
Temperature Range
• TTL Quadrature Output
• Single 5 V Supply
• Available with Color Coded
Leads
Description
The HEDS-5700 series is a family
of low cost, high performance,
optical incremental encoders with
mounted shafts and bushings. The
HEDS-5700 is available with
tactile feedback for hand operated
panel mount applications, or with
a free spinning shaft for applications requiring a pre-assembled
encoder for position sensing.
The encoder contains a collimated
LED light source and special
detector circuit which allows for
high resolution, excellent encoding performance, long rotational
life, and increased reliability. The
unit outputs two digital waveforms which are 90 degrees out of
phase to provide position and
direction information. The
HEDS-5740 Series provides a
third Index Channel.
Package Dimensions
THREAD 3/8-32
NUT 3/8-32 x 7/16"
OPTIONAL WIRING
COLOR CODE TABLE
*
COLOR
WHITE
BROWN
RED
BLACK
BLUE
(THREE
CHANNEL)
OUTPUT
A
B
VCC
GND
I
*Note: For the HEDS-5700, Pin #2 is a No Connect. For
the HEDS-5740, Pin #2 is Channel I, the index output.
2-116
5965-5871E
applications requiring digital
information from a manually
operated knob. Typical front
panel applications include
instruments, CAD/CAM systems,
and audio/video control boards.
Applications
The HEDS-5700 without static
drag (free spinning) is best suited
for low speed, mechanized
The HEDS-5700 with the static
drag option is best suited for
operations. Typical applications
are copiers, X-Y tables, and
assembly line equipment.
MOTION SENSING
AND CONTROL
The HEDS-5700 is quickly and
easily mounted to a front panel
using the threaded bushing, or it
can be directly coupled to a motor
shaft (or gear train) for position
sensing applications.
Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Units
Ts
Ta
-40
-20
+85
+85
20
7
VCC
5
1
1
°C
°C
g
V
V
mA
lb
lb
Storage Temperature
Operating Temperature
Vibration
Supply Voltage
Output Voltage
Output Current per Channel
Shaft Load – Axial
– Radial
VCC
VO
IO
-0.5
-0.5
-1
Notes
20 Hz - 2 kHz
Recommended Operating Conditions
Parameter
Symbol
Min.
Max.
Units
Notes
Temperature
Supply Voltage
Rotational Speed – Drag
– Free Spinning
T
VCC
-20
4.5
+85
5.5
300
2000
°C
V
RPM
RPM
Noncondensing Atmosphere
Ripple <100 mVp-p
Electrical Characteristics Over Recommended Operating Range, Typical at 25°C
Parameter
Symbol
Supply Current
ICC
High Level Output Voltage
Low Level Output Voltage
VOH
VOL
Min.
Typ.
Max.
Units
17
40
mA
57
85
2.4
0.4
V
V
Notes
Two Channel
Three Channel
IOH = -40 µA Max.
IOL = 3.2 mA
Note: If more source current is required, use a 3.2 K pullup resistor on each output.
2-117
Mechanical Characteristics
Parameter
Min.
Starting Torque – Static Drag
– Free Spinning
Dynamic Drag
– Static Drag
– Free Spinning
Rotational Life – Static Drag
– Free Spinning
Mounting Torque of Nut
Output Waveforms
Typ.
Max.
0.47
0.14
1.1
0.70
1 x 106
12 x 106
13
Units
oz in
oz in
oz in
oz in
Revolutions
Revolutions
lb in
Notes
100 RPM
2000 RPM
1 lb Load
4 oz Radial Load
360 ± 5.5
CH A
180 ± 45
S1
S2
S3
S4
90 ± 45 TYPICAL
CH B
90 ± 45
CH I
NOTE:
ALL VALUES ARE IN ELECTRICAL DEGREES, WHERE 360° e = 1 CYCLE OF RESOLUTION.
ERRORS ARE WORST CASE OVER ONE REVOLUTION.
CH B LEADS CH A FOR COUNTERCLOCKWISE ROTATION.
CH A LEADS CH B FOR CLOCKWISE ROTATION.
Ordering Information
HEDS-57
Outputs
0 - 2 Channel
4 - 3 Channel
Mechanical
Configuration
0 - Pins
1 - 6" Coded Leads
Resolutions
(Cycles Per Revolution)
HEDS-570X 2 Channel
K - 96 CPR
G - 360 CPR
C - 100 CPR
H - 400 CPR
D - 192 CPR
A - 500 CPR
E - 200 CPR
I - 512 CPR
F - 256 CPR
HEDS-574X Three Channel*
F - 256 CPR
A - 500 CPR
G - 360 CPR
I - 512 CPR
*Please contact factory for other resolutions.
2-118
Drag Option
0 - Free Spining
1 - Static Drag
Shaft Configuration
0 - 1/4" dia. with no flat
1 - 6 mm dia. with no flat
2 - 1/4" dia. with flat