18W AC-DC High Reliability Industrial Adaptor ■ Features Universal AC input / Full range 2 pole AC inlet IEC320-C8 No load power consumption< 0.075W Energy efficiency Level VI Comply with EISA 2007/DoE,NRCan, GST18B series ■ Applications Consumer electronic devices Telecommunication devices Office facilities Industrial equipments AU/NZ MEPS,EU ErP and CoC Version 5 Class Ⅱ power (without earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case Pass LPS High operating temperature up to +70℃ LED indicator for power on 3 years warranty ■ Description GST18B is a highly reliable, 18W desktop style single-output green adaptor series. This product is a classⅡ power unit (without FG), equipped with a standard IEC320-C8 AC inlet and adopting the input range from 85VAC to 264VAC. The entire series supplies different models with output voltages ranging between 5VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With the efficiency up to 89% and the extremely low no-load power consumption below 0.075W,GST18B is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP, and Code of Conduct(CoC) Version 5 . The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GST18B is certified for the international safety regulations. ■ Model Encoding GST 18 B 05 - P1J DC plug type { P1J : Plug for standard model, 2.1ψ × 5.5ψ ×11mm, c+, tuning fork type Optional plug type available by customer requested Output voltage IEC320-C8 AC inlet Output wattage Series name File Name:GST18B-SPEC 2015-06-24 GST18B 18W AC-DC High Reliability Industrial Adaptor series SPECIFICATION GST18B05-P1J GST18B07-P1J GST18B09-P1J GST18B12-P1J GST18B15-P1J GST18B18-P1J GST18B24-P1J GST18B28-P1J GST18B48-P1J ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT GST18B05 Note.2 5V GST18B07 GST18B09 GST18B12 GST18B15 GST18B18 GST18B24 GST18B28 7.5V 9V 12V 15V 18V 24V 28V 48V 2.0A 1.50A 1.20A 1.0A 0.75A 0.64A 0.375A RATED CURRENT 3.0A 2.0A CURRENT RANGE 0 ~ 3.0A 0 ~ 2.0A 0 ~2.0A 0 ~ 1.50A 0 ~ 1.20A 0 ~ 1.0A 0 ~ 0.75A 0 ~ 0.64A 0 ~ 0.375A RATED POWER (max.) 15W 15W 18W 18W 18W 18W 18W 18W 18W RIPPLE & NOISE (max.) Note.3 80mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0% LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION Note.6 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0% 88% 88.5% 89% SETUP, RISE, HOLD UP TIME 1000ms, 30ms, 50ms/230VAC Note.7 85 ~ 264VAC VOLTAGE RANGE FREQUENCY RANGE INPUT 47 ~ 63Hz 81% AC CURRENT INRUSH CURRENT (max.) 0.5A / 115VAC 0.3A / 230VAC 35A / 115VAC 65A / 230VAC LEAKAGE CURRENT(max.) 0.25mA / 240VAC OVERLOAD 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 110 ~ 140% rated output voltage Protection type : Clamp by zener diode, output short -30 ~ +70℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 8) EMC EMISSION EMC IMMUNITY MTBF DIMENSION OTHERS NOTE 1500ms, 30ms, 15ms/115VAC at full load EFFICIENCY (Typ.) PROTECTION CONNECTOR GS18B48 85% 85% 86% 87% 88% ±0.03% / ℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved I/P-O/P:4242VDC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 500Khrs min. MIL-HDBK-217F(25℃) PACKING PLUG 79*54*33mm (L*W*H) 191.5g; 60pcs/12.5Kg/1.22CUFT See page 3 ; Other type available by customer requested CABLE See page 3 ; Other type available by customer requested 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 10% to 100% rated load. 7.Derating may be needed under low input voltage. Please check the derating curve for more details. 8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:GST18B-SPEC 2015-06-24 GST18B 18W AC-DC High Reliability Industrial Adaptor Derating Curve series Static Characteristics 100 85 LOAD (%) LOAD (%) 100 50 80 70 60 50 40 -30 10 20 30 40 50 60 70 85 AMBIENT TEMPERATURE (℃) 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Mechanical Specification Unit:mm UL1185 16AWG 1200±50mm for 5~12V UL1185 18AWG 1800±50mm for 15~48V 70±10mm POWER LED C"+" 11±0.5mm ID 2.1 x OD 5.5 NAME PLATE Plug Assignment 79 33 Standard plug: P1J 54 P1J P/N OUTPUT CENTER + Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html File Name:GST18B-SPEC 2015-06-24