Emerson Network Power DA4-050US Switching wallmount power supply Datasheet

Embedded Power for
Business-Critical Continuity
Rev. 10.01.08_124
DA4 Series
of 3
DA4 Series
4 Watts
DA4-050EU
DA4-050US
Total Power:
Input Voltage:
# of Outputs:
DA4-050CH
4 Watts
90-264 VAC
Single
RoHS
Electrical Specifications
Special Features
Input
Input ra­nge
90-264 VAC (wide range)
• Switching wallmount
power supply
• Available in multiple AC plug
configurations
• CE Mark EMC & LVD
• Universal AC input
• Regulated output
• Overload and short circu­it
protection
• Constant voltage, constant
current
• High MTBF
• Built in EMI filter (CISPR 22
Class B)
• LED power good indicator
Frequency
EMI/RFI
47-63 Hz
FCC Part 15, Subpart B Class B & EN55022
(CISPR 22) Class B &EMC89/336/EEC
Safety ground
leakage current
100 µA @ 50/60 Hz, 230 VAC input
Output
Voltage (Vo)
5.5V (5.0V - 6.0V)
Maximum Power (Po)
4W
Hold-up time
Overvoltage protection
15 ms. typical at full load @ 115 VAC
25% above nominal output maximum
Latching type
Output short circuit protection auto recover
Overload protected > 800mA
DC cable with 2.5 mm x 5.5 mm barrel plug
DC plug center +V; DC plug outer -V
DC plug center -V; DC plug outer +V
Overload protection
Output cable/
connector barrel polarity
Reverse polarity
-0001 suffix
Environmental Specifications
Operating temperature:
Safety
UL
CSA
TUV
NEMKO
CB
CE
CCC
60950 / 6500
60950
60950
60950
Certificate and report
EMC & LVD
Mark
0° to 50°C ambient
-40°C to +85°C
Storage temperature:
Electromagnetic
susceptibility:
Designed to meet EN55082-1
Humidity:
Operating; non-condensing 20% to 90% RH
Vibration:
Per IEC 60068-2-6
Embedded Power for
Business-Critical Continuity
Rev.10.01.08_124
DA4 Series
of 3
Ordering Information
Model
Number
Maximum
Power
Output
Voltage
Minimum
Load
Maximum
Load
Peak Load
Ripple
P/P (PARD)1
DA4-050US
4W
5.5V
0
0.75A
0.80A
150mV
DA4-050EU
4W
5.5V
0
0.75A
0.80A
150mV
DA4-050CH
4W
5.5V
0
0.75A
0.80A
150mV
1. Peak-to-peak with 1 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
2­. Output should not be crounded for EMI purpose.
3­. Add -0001 suffix to the part number for reverse polarity, for example DA4-050US-0001.
Mechanical Drawing
DA4-050US
CASE TOP
1.80"
(45.8)
1.57"
(39.8)
78.7"
(2000.0)
CASE BOTTOM
1.02"
(26.0)
2.36"
(60.0)
DA4-050EU
1.57"
(39.8)
78.7"
(2000.0)
2.36"
(60.0)
2.23"
(58.3)
CASE TOP
1.02"
(26.0)
CASE BOTTOM
Embedded Power for
Business-Critical Continuity
Americas
Mechanical Drawing
Rev. 10.01.08_124
DA4 Series
of 3
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
DA4-050CH
CASE TOP
2.36"
(60.0)
1.80"
(45.8)
1.57"
(39.8)
78.7"
(2000.0)
Europe (UK)
1.02"
(26.0)
CASE BOTTOM
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.astecpower.com
www.artesyn.com
[email protected]
[email protected]
Notes:
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
1. Specifications subject to change without notice.
2. all dimensions in inches (mm), tolerance is ±.02”­
3. Warranty: 2 year
4. Weight: 0.181 lb. / 0.082 kg.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2007 Emerson Electric Co.
Similar pages