yangjie D4UB100 Bridge rectifier Datasheet

RoHS
D4UB05 THRU D4UB100
COMPLIANT
Bridge Rectifiers
Features
● UL recognition, file #E230084
● Ideal for printed circuit boards
● High surge current capability
● Solder dip 275 °C max. 7 s, per JESD 22-B106
Typical Applications
General purpose use in AC/DC bridge full wave
rectification for monitor, TV, printer, power supply, switching
mode power supply, adapter, audio equipment, and home
appliances applications.
Mechanical Data
● Package: D3K
+
~
~
Molding compound meets UL 94 V-0 flammability
rating, RoHS-compliant
● Terminals: Tin plated leads, solderable per
J-STD-002 and JESD22-B102
● Polarity: As marked on body
-
■Maximum Ratings (Ta=25℃ Unless otherwise specified)
PARAMETER
SYMBOL
UNIT
Device marking code
Repetitive peak reverse voltage
VRRM
V
IO
A
With heatsink
Average rectified output
Tc =140℃
current @60Hz sine wave,
Without heatsink
R-load
Ta =29℃
Surge(non-repetitive)forward current
@60Hz half sine wave, 1 cycle, Tj=25℃
Current squared time
@1ms≤t≤8.3ms Tj=25℃, Rating of per diode
D4UB05
D4UB10
D4UB20
D4UB40
D4UB60
D4UB80 D4UB100
D4UB05
D4UB10
D4UB20
D4UB40
D4UB60
D4UB80 D4UB100
50
100
200
400
600
800
1000
4.0
1.3
IFSM
A
I2t
As
Storage temperature
Tstg
℃
-55 ~+150
Junction temperature
Tj
℃
-55 ~+150
Dielectric strength
@ Terminals to case, AC 1 minute
Vdis
KV
2
Mounting torque
@Recommend torque:5kg·cm
Tor
kg·cm
8
135
2
75
■Electrical Characteristics(Ta=25℃ Unless otherwise specified)
PARAMETER
Maximum instantaneous forward
voltage drop per diode
Maximum DC reverse current at
rated DC blocking voltage per diode
SYMBOL UNIT
TEST
CONDITIONS
VF
V
IFM=2.0A
IRRM
μA
VRM=VRRM
D4UB05 D4UB10 D4UB20 D4UB40 D4UB60 D4UB80 D4UB100
1.0
5
1/4
S-B008
Rev. 2.0, 28-Apr-14
Yangzhou Yangjie Electronic Technology Co., Ltd.
www.21yangjie.com
D4UB05 THRU D4UB100
■Thermal Characteristics (Ta=25℃ Unless otherwise specified)
PARAMETER
Thermal
resistance
SYMBOL
Between junction and
ambient, Without
heatsink
Between junction
and case, With
heatsink
UNIT
D4UB05
D4UB10
D4UB20
D4UB40
RθJ-A
D4UB60
D4UB80
D4UB100
55
℃/W
RθJ-C
1.5
■Ordering Information (Example)
PREFERED P/N
PACKING
CODE
UNIT WEIGHT(g)
MINIIMUM
PACKAGE(pcs)
INNER BOX
QUANTITY(pcs)
OUTER CARTON
QUANTITY(pcs)
DELIVERY MODE
D4UB05- D4UB100
B1
Approximate 1.266
25
1500
6000
TUBE
D4UB05- D4UB100
A1
Approximate 1.266
500
500
9000
BOX
■ Characteristics (Typical)
FIG2:Surge Forward Current Capability
FIG1:Io-Tc Curve
140
120
4.0
3.0
2.0
heatsink
sine wave R-load
with heatsink
Tc-sensing point
1.0
0
half sine wave
0
100
non-repetitive
Tj=25℃
80
60
40
20
0
40
80
120
0
160
FIG3: Forward Voltage
1
2
5
10
20
Number of Cycles
50
100
FIG4:Typical Reverse Characteristics
100
6
Tj=150℃
Instantaneous Reverse Current (uA)
4
Instantaneous Forward Current (A)
8.3ms 8.3ms
1cycle
Case Temperature (℃)
`
IFSM
5.0
Peak Forward surge Current
Average Forward Output Current (A)
6.0
2
1
0.5
Ta=25℃
0.1
0.05
10
1.0
Tj=25℃
0.1
0.02
0.01
0.01
0.4
0.6
0.8
1.0
1.2
Instantaneous Forward Voltage (V)
0
1.4
20
40
60
80
100
Percent of Rated Peak Reverse Voltage (%)
2/4
S-B008
Rev. 2.0, 28-Apr-14
Yangzhou Yangjie Electronic Technology Co., Ltd.
www.21yangjie.com
D4UB05 THRU D4UB100
■ Outline Dimensions
D3K
D3K
I
A
C
D
J
B
E
K
H
Dim
Min
Max
A
13.30
14.30
B
10.30
11.30
C
6.40
7.40
D
4.50
5.50
E
1.05
1.45
F
0.60
0.85
G
3.70
3.90
H
13.10
13.50
I
2.60
3.60
J
3.10
3.40
K
2.00
2.20
L
0.40
0.60
F
L
G
G
G
Dimensions in millimeters
3/4
S-B008
Rev. 2.0, 28-Apr-14
Yangzhou Yangjie Electronic Technology Co., Ltd.
www.21yangjie.com
D4UB05 THRU D4UB100
Disclaimer
The information presented in this document is for reference only. Yangzhou Yangjie Electronic Technology Co., Ltd. reserves the
right to make changes without notice for the specification of the products displayed herein to improve reliability, function or design
or otherwise.
The product listed herein is designed to be used with ordinary electronic equipment or devices, and not designed to be used with
equipment or devices which require high level of reliability and the malfunction of with would directly endanger human life (such as
medical instruments, transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers and other safety
devices), Yangjie or anyone on its behalf, assumes no responsibility or liability for any damages resulting from such improper use
of sale.
This publication supersedes & replaces all information previously supplied. For additional information, please visit our website
http:// www.21yangjie.com , or consult your nearest Yangjie’s sales office for further assistance.
4/4
S-B008
Rev. 2.0, 28-Apr-14
Yangzhou Yangjie Electronic Technology Co., Ltd.
www.21yangjie.com
Similar pages