Keysight M9121A Pxi matrix switch module Datasheet

Keysight Technologies
PXI Matrix Switch Modules
M9120A, M9121A, M9122A
Data Sheet
02 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Overview
Product Description
The Keysight Technologies, Inc. PXI matrix switch modules
activate multiple channels in a single instance. Select a
switch row to connect to any column and create routing
for multiple signals between instruments and the device
under test. Choose from high-speed, long-life reed relays
capable of switching up to 100 Vrms with up to 20 W of
power, or the higher power armature relays capable of
switching up to 60W of power. Multiple switch matrices
offer a variety of power and switch density options.
Installation and coniguration is fast and easy with
standard cable connections or an optional connector
block, soft front panels, and Keysight Connection Expert.
In addition, software drivers support the most common
programming environments such as Visual Studio, C, C++,
Visual Basic, MATLAB, and LabVIEW.
Applications
–
–
–
–
–
Aerospace and defense
Automotive
Electronic test
Medical
Semiconductor
Features
– Quickly connect multiple high-voltage points
– High-density modules provide more connections in a
smaller area
– Up to 256 2-wire crosspoints
– High-speed, long-life reed relays or higher power
armature relays
– Software drivers support the most common
programming environment
– Optional connector blocks offer reliable measurement
from robust, high-pincount interconnects
– Easy programming and control with soft front panels
and Keysight Command Expert
Customer Values
– Connect multiple points for high-pin-count
applications
– Get the performance you need with high-speed
1000 μs reed relay switches or up to 60 W per
channel
– Work in your programming environment of choice
and reduce development time
– Fast and easy module installation and coniguration
03 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Easy Setup ... Test ... and Maintenance
Hardware Platform
Software Applications
Compliance
Keysight soft front panels provide easy-to-use instrument
communications. The PXI matrix switch graphical user
interface guides developers through module setup so
users can quickly conigure the switch states. Switch
control is also possible through the wide selection of
instrument program interfaces.
The matrix switch modules are PXI compliant with a J1
connector and can be used in PXI chassis with cPCI (J1),
PXI-1 (J1 only), or PXIe hybrid slot connectors.
The PXI format offers high performance in a small, rugged
package. It is an ideal deployment platform for many
automated test systems. In addition, a wide array of complementary PXI products are currently available, such as
multimeters, waveform generators, local oscillators,
digitizers, and RF switch modules.
Software Platform
IO Libraries
Keysight IO Libraries Suite offers fast and easy instrument
connections and now extends to modular instruments. IO
Libraries Suite 16 adds support for PXI, helping you
display all of the modules in your system, whether they
are PXI, PXIe, or AXIe, as well as view information about
installed software. In addition, the new version allows you
to more easily ind the right driver and start module soft
front panels directly with Keysight Connection Expert.
Drivers
Keysight provides instrument drivers that work with your
choice of software, saving time and preserving software
and hardware investments. Keysight modular instruments
come with IVI-COM, IVI-C, and LabVIEW software drivers
that work in the most popular test and measurement
development environments including LabVIEW, MATLAB,
LabWindows/CVI, Visual Studio C, C++, C#, VEE, and
Visual Basic.
With a broad selection of drivers already included, any
Keysight PXI matrix switch can be swapped out, replaced,
or upgraded with the latest version, requiring only minimal
software adjustments.
Easy software integration
In addition, application code examples are included for
LabVIEW, LabWindows/CVI, Visual Studio C, C++, C#,
Visual Basic, and MATLAB, providing switch set-up and
basic functionality. These application code examples are
easily modiied to quickly integrate the switch module into
your measurement system.
Figure 1. Matrix switch soft front panel
04 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Speciications and Characteristics
Speciication and Characteristic Summary
Following is a summary of speciications and characteristics for the Keysight PXI matrix switches. More detailed speciications and characteristics for each module are featured later in this document.
Matrix switch speciication and characteristic summary
Multiplexer
switches
Description
Type
# slots
Channels
Switch speed
(typical)
Max
voltage
Current switch Relay type
and carry
Connectors
M9120A
Matrix
switch
PXI
1-slot
4x32,
2-wire
3 msec
100 Vrms1
2 A/2 A
Armature
78 Dsub
connector
block or cable
M9121A
High density
matrix
switch
PXI
1-slot
4x64,
2-wire
< 1 msec2
100 Vrms1
0.5 A/0.5 A
0.5 A/0.5 A
200 LFH
connector
block or cable
M9122A
Matrix
switch
PXI
1-slot
8x32,
1-wire
3 msec
100 Vrms1
2 A/2 A
Armature
50 Dsub
connector
block or cable
1. Not for connection to mains
05 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Speciications and Characteristics (continued)
M9120A 4x32, 2-wire PXI matrix switch
The M9120A high-density matrix is designed to switch
medium voltage/power signals. The 128, 2-wire armature
relays offer higher voltage switching and up to 60W per
channel. This module is ideal for telecom applications that
need to simultaneously send and return signals.
The matrix module includes a 4-wire-wide bus to route
signals between test instruments and your device under
test. To create larger matrices, multiple modules can be
linked together, for example, four rows of two M9120A
modules can be joined to create a 4x64 matrix. Easily connect to the matrix with a 78-pin Dsub female connector or
cable.
M9120A speciications and characteristics
General speciications
Channels
4x32
Switch type
Medium power, 2-wire
armature
Max volts1
100 Vrms
Max switch rating/carry rating
2.0 A
Switching characteristics (nominal)
Max power
60 W
Switch speed (typical)
3 msec
Inital path resistance,
differential (typical)
500 mΩ
Connectors
78 Dsub
connector block or cable
Bandwidth
7.5 MHz
DC isolation, Ch-Ch,
Ch-Gnd
25C / 40%RH (typical)
25C / 80%RH (typical)
40C / 80%RH (typical)
1x1010 Ω
1x10 8 Ω
1x107 Ω
Thermal offset,
single-ended (typical)
Figure 2. M9120A 4x32, 2-wire, armature relays
Relay life, operations2
Low power load (typical)
Rated power load (typical)
8 μV
> 1x107
> 1x105
1. Not for connection to mains
2. Relay life is deined as path resistance <1.4 Ω
Figure 3. 78-pin Dsub connector block
06 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Speciications and Characteristics (continued)
M9121A 4x64, 2-wire PXI high-density
matrix switch
The M9121A ultra-high-density 4x64, full-crosspoint
switch matrix, offers high-speed reed relay signal
switching in a single PXI module. The crosspoints of the
high-speed, 2-wire, long-life reed switches can be rapidy
activated to route signals in your test system. The matrix
relays support signal switching up to 100 Vrms with 10 W
maximum power. The module includes a 4-wire-wide bus
to route signals between test instruments and your device
under test. To create larger matrices, multiple modules
can be linked together. For example, four rows of two
M9121A modules can be joined to create a 4x128 matrix.
Easily connect to the matrix with a high-density, 200-pin
low force helix (LFH) connector or cable.
M9121A speciications and characteristics
General speciications
Channels
4x64
Switch type
Ultra-high-density, 2-wire
reed
Max volts1
100 Vrms
Max switch rating/carry rating
0.5 A
Switching characteristics (nominal)
Max power
10 W
Switch speed (typical)
< 1 ms
Inital path resistance,
differential (typical)
900 mΩ
Connectors
200 LFH
connector block or cable
Bandwidth
10 MHz
DC isolation, Ch-Ch,
Ch-Gnd, typical per channel
25C / 40%RH
25C / 80%RH
40C / 80%RH
1x1010 Ω
1x107 Ω
1x10 6 Ω
Thermal offset, differential
(typical)
Figure 4. M9121A 4x64, 2-wire, reed relays
Relay life, operations2
Low power load (< 10 V)
load (typical)
Up to 100 V (typical)
6 μV
1x109
1x10 6
1. Not for connection to mains
2. Relay life is deined as path resistance <1.4 Ω
Figure 5. 200-pin LFH connector block
07 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
M9122A 8x32, 1-wire, PXI Matrix Switch
The M9122A high-density, full 8x32 crosspoint switch
matrix offers high-voltage switching in a PXI module.
The matrix is designed with durable electromechanical
switches that are capable of switching up to 100 Vrms,
with up to 60 W of power.
Choose from crosspoints arranged in eight rows and
32 columns that can be activated instantaneously to
route signals in your test system. The module includes
an 8-wire-wide bus to easily route signals between test
instruments and the device under test. To create larger
matrices, multiple modules can be linked together. For
example, create a larger matrix by joining eight rows of
two M9122A modules to create a 16x32 matrix. Easily
connect to the matrix with a 50-pin Dsub connector or
cable.
M9122A speciications and characteristics
General speciications
Channels
8x32
Switch type
1
1-wire, armature
Max volts
100 Vrms
Max switch rating/carry rating
2.0 A
Switching characteristics (nominal)
Max power
60 W
Switch speed (typical)
3 msec
Inital path resistance,
single ended (typical)
250 mΩ
Connectors
50 Dsub
connector block or cable
Bandwidth
5 MHz
DC isolation, Ch-Ch,
Ch-Gnd
25C / 40%RH (typical)
25C / 80%RH (typical)
40C / 80%RH (typical)
1x1010 Ω
1x10 8 Ω
1x107 Ω
Thermal offset, single-ended
(typical)
Relay life, operations2
Low power load (typical)
Rated power load
(typical)
6 μV
1x107
1x105
1. Not for connection to mains
2. Relay life is deined as path resistance <1.4 Ω
Figure 6. M9122A 8x32, 1-wire, armature relays
08 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Speciications and Characteristics
General speciications
Slot type
Connector type
PXI 1-slot
M9120A
M9121A
M9122A
78 Dsub connector
block or cable
200 LFH connector
block or cable
50 Dsub connector block
or cable
Environmental characteristics 1, 2
Temperature
Operating: 0° to 55°C
Non-operating: -40° to +70°C
Relative humidity
Relative humidity: Up to 95% R.H. at 40˚ C, non-condensing, pollution degree 1
EMC
European EMC Directive 2004/108/EC
– IEC/EN 61326-1
– CISPR Pub 11 Group 1, Class A
– AS/NZS CISPR 11
– ICES/NMB-001
Canadian ISM device ICS-001
Safety
European Low Voltage Directive 2006/95/EC
– ETL, UL/IEC/EN 61010-1, 2nd Edition
Altitude under relative humidity
Altitude: up to 4.6 km (15,000 ft)
Warm-up time
15 minutes, max
1. Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and veriied to be robust against the
environmental stresses of storage, transportation, and end-use; those stresses include, but are not limited to temperature, humidity, shock,
vibration, altitude, and power line conditions.
2. Test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F class 3
Physical characteristics
Dimensions
Weight
– 3U/1-slot PXI/CompactPCI standard
– Connector slot compatibility: cPCI (J1), PXI-1, PXIe hybrid slot
– Front panel complies with IEEE1101.10 certiication and compliance
M9120A
M9121A
M9122A
260 g
(.57 lbs)
400 g
(.88 lbs)
380 g
(.87 lbs)
M9120A
M9121A
M9122A
0
0
100 mA (typ)
+5V
400 mA (typ)
400 mA (280 mA) (typ)
400 mA (typ), 1.3 A max
+12V
0
0
50 mA (typ)
Power requirements
+3.3V
09 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Speciications and Characteristics (continued)
System requirements
Topic
Windows 7 and Vista Requirements
Windows XP Requirements
Operating systems
Windows 7 (32-bit and 64-bit)
Windows Vista, SP1 and SP2 (32-bit and
64-bit)
Windows XP, Service Pack 3
1 GHz 32-bit (x86), 1 GHz 64-bit (x64)
(no support for Itanium 64)
1 GHz 32-bit (x86), 1 GHz 64-bit (x64)
(no support for Itanium 64)
600 MHz or higher required
800 MHz recommended
Available disk space 1
1.5 GB available hard disk space, includes:
– 1 GB available for Microsoft .NET
Framework 3.5 SP1 2
– 100 MB for Keysight IO Libraries Suite
1.5 GB available hard disk space,
includes:
– 1 GB available for Microsoft .NET
Framework 3.5 SP1 2
– 100 MB for Keysight IO Libraries Suite
Video
Support for DirectX 9 graphics with 128
MB graphics memory recommended
(Super VGA graphics is supported)
Super VGA (800 x 600) 256 colors or more
Browser
Microsoft Internet Explorer 7.0 or greater
Microsoft Internet Explorer 6.0 or greater
1. Because of the installation procedure, less memory may be required for operation than is required for installation.
2. NET Framework Runtime Components are installed by default with Windows Vista and Windows 7. Therefore, you may not need this amount
of available disk space.
10 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Speciications and Characteristics (continued)
Instrument Connection Software
Keysight IO
Library
Keysight IO Libraries Suite offers a single entry point for
a connection to modular and traditional instruments. It
automatically discovers interfaces, chassis, instruments, and
identiies updates to IVI instrument drivers. IO Libraries Suite
safely installs in side-by-side mode with NI I/O software.
Free software
Download from A.com
(www.keysight.com/
ind/iosuite)
Keysight
Connection
Expert
The Keysight Connection Expert is the Graphical User interface
included in the IO Libraries Suite that allows you to search
for, verify and update IVI instrument and soft front panel
drivers for modular and traditional instruments.
Free software
Included in the IO
Libraries (www.keysight.
com/ind/iosuite)
Keysight
Soft
Front Panel
The PXI module includes a Soft Front Panel (SFP), a software-based Graphical User Interface (GUI) which enables
the instrument’s capabilities from your PC.
Included on CD-Rom
with module
Driver
Development environments
lVI-COM
IVI-C
LabVIEW
Visual Basic
Visual Studio
(VB.NET, C#, C/C++)
VEE
LabVIEW, LabWindows/CVI, MATLAB
Included on CD-Rom
with module or
Download from www.
keysight.com
Command
Expert
Assists in inding the right instrument commands and
setting correct parameters. A simple interface includes
documentation, examples, syntax checking, command
execution and debug tools to build sequences for integration
in Excel, MATLAB, Visual Studio, LabVIEW, VEE, SystemVue.
Free software
Download from www.
keysight.com
(www.keysight.com/
ind/commandexpert)
Each module includes programming Program examples
available for LabVIEW, LabWindows/CVI, Visual Studio C,
C++, C#, Visual Basic, and MATLAB
Download from www.
keysight.com
Signal
Studio
Suite of signal-creation tools which provides performanceoptimized reference signals for: W-CDMA/HSPA+,
cdma2000/1xEV-DO, GSM/EDGE/Evo, LTE/LTE-Advanced
FDD, LTE/LTE-Advanced TDD, TD-SCDMA/HSDPA, WLAN
802.11a/b/g/n/ac, and Bluetooth.
Licensed software
(www.keysight.com/
ind/signalstudio)
System
View
A system–level EDA that accelerates design and veriication
at the physical layer where advanced digital signal
processing meets RF.
Licensed software
(www.keysight.com/
ind/eesof-systemvue)
Interactive tools and command-line functions for instrument
control and data analysis tasks such as signal processing,
signal modulation, digital iltering, and curve itting.
Licensed software
89600 VSA software sees through the complexity of
emerging and existing industry standards serving as your
window into complex signal interactions
Licensed software
(www.keysight.com/
ind/vsa)
Module Management
Module Setup and Usage
Programming
Drivers
Programming Assitance
Programming
examples
Signal Generation Software
MATLAB
Signal Analysis Software
Vector
Signal
Analysis
11 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Setup and Calibration Services
Assistance
An Keysight Technologies applications engineer will help you
get started and install the modules in a chassis, conigure the
controller, load software and make irst measurements.
Included in base coniguration
Factory Calibration
Keysight’s modular products M9120A, M9121A, M9122A are
factory calibrated and shipped with an ISO-9002, NIST-traceable calibration certiicate.
Included in base
coniguration
Calibration Cycle
A one year calibration cycle is recommended
Included in base
coniguration
Calibration Sites
– At Keysight Worldwide Service Centers
– On-site by Keysight
– By self-maintainers
More information on
www.keysight.com/ind/infoline
R1282A Annual Calibration
Service
–
–
–
–
–
Additional service, not included in the
warranty
On day startup assistance
Calibration and Traceability
Keysight Calibration
Keysight Calibration + Uncertainties
Keysight Calibration + Uncertainties + Guardbanding
Standards Compliance
ANSI Z540.3-2006, ISO 17025:2005, ANSI Z540-1-1994,
ISO 9001:2008
12 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Coniguration and Ordering
Related Products
Hardware
Model
Description
Model
Description
Each switch
includes:
Getting started guide, software drivers,
and Keysight I/O libraries
M9018A
Getting started guide, software drivers,
and Keysight I/O libraries
M9120A
PXI matrix switch: 4x32, 2-wire,
100V/2A, EM relays
M9021A
PXI matrix switch: 4x32, 2-wire,
100V/2A, EM relays
M9121A
PXI high-density matrix switch: 4x64,
2-wire, 100V/0.5A, reed relays
M9045B
PXI high-density matrix switch: 4x64,
2-wire, 100V/0.5A, reed relays
M9122A
PXI matrix switch: 8x32, 1-wire,
100V/2A, armature relays
Y1200B
PXI matrix switch: 8x32, 1-wire,
100V/2A, armature relays
M9048A
PCIe PC adapter
Y1202A
PCIe cable: x8, 2.0m (used with
M9047B)
Accessories
M9120A
Description
Y1181A
PXI connector block: 78-pin, shielded,
female DSub
Y1187A
PXI connector cable: 78-pin, male-to
female, 1 meter
Y1188A
PXI connector cable: 78-pin, male-to
female, 2 meter
M9121A
Description
Y1182A
PXI connector block: 200-pin, shielded, male
Y1189A
PXI connector cable: 200-pin, LFH male
to four 50 pin Dtype female connectors,
1 meter
Y1190A
PXI connector cable: 200-pin, LFH male
to four 50 pin Dtype female connectors,
2 meter
M9122A
Description
Y1180A
PXI connector block: 50-pin, female DSub
Y1185A
PXI connector cable: 50-pin, male-tofemale,
1 meter
Y1186A
PXI connector cable: 50 pin, male-tofemale,
2 meter
Software
Model
Description
Supported
operating
systems
Microsoft Windows XP (32-bit),
Microsoft Windows Vista (32/64-bit)
Microsoft Windows 7 (32/64-bit)
Standard
compliant
drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported
application
development
environments
(ADE)
VisualStudio (VB.NET, C#, C/C++),
LabVIEW, LabWindows/CVI, MATLAB
Keysight IO
Libraries
Includes: VISA Libraries, Keysight
Connection Expert, IO Monitor
Recommended Chassis Coniguration
For the ultimate in speed and lexibility, combine your switches
with other PXI modules in the Keysight M9018A PXIe chassis as
follows:
– Select a PXIe system module, PCIe cable interface,or embedded controller (the Keysight M9021A is recommended)
– If an external computer is being used, select an appropriate
PC interface card (the Keysight M9047A is recommended with
an external PC)
– Select an appropriate cable to connect the computer interface
board to the system module (the Y1202A is recommended to
connect the M9047A and M9021A)
– Select rack mount and EMC iller panel kits as required
13 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
Deinitions for speciications
Speciications describe the warranted performance of
calibrated instruments that have been stored for a minimum of 2 hours within the operating temperature range of
0 to 55°C, unless otherwise stated, and after a 45 minute
warm-up period. Data represented in this document are
speciications unless other wise noted.
Warranty and Calibration
Advantage Services: Calibration and Warranty
Keysight Advantage Services is committed to your success
throughout your equipment’s lifetime
Warranty
Standard warranty is 1 year1
Characteristics describe product performance that is
useful in the application of the product, but that is not
covered by the product warranty. Characteristics are
often referred to as Typical or Nominal values.
– Typical describes characteristic performance, which
80% of the instruments will meet when operated over
a 20 to 30°C temperature range. Typical performance
is not warranted.
– Nominal describes representative performance that
is useful in the application of the product when operated over a 20 to 30°C temperature range. Nominal
performance is not warranted.
Note: All graphs contain measured data from several
units at room temperature unless otherwise noted.
R-51B-001-3C
1 year return-to-Keysight warranty
extended to 3 years
1. Excludes relay wear-out.
14 | Keysight | PXI Matrix Switch Modules M9120A, M9121A, M9122A - Data Sheet
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of
the PCI Industrial Computer Manufacturers Group.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
“PCIe” is a registered trademarks of PCI-SIG.
www.keysight.com/find/modular
www.keysight.com/find/pxi-switch
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Paciic
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-09-23-14)
This information is subject to change without notice.
© Keysight Technologies, 2013 - 2014
Published in USA, August 3, 2014
5990-7182EN
www.keysight.com
Similar pages