AIMTEC AM10EW-4805SZ 10 watt | dc-dc converter Datasheet

Series AM10EW-Z
10 Watt | DC-DC Converter
FEATURES:
 RoHS compliant
 Efficiency up to 85%
 Wide 4:1 input range
 Continuous Short Circuit Protection


●
●
Low ripple and noise
Remote on/off control
Input/Output Isolation 1500VDC
Operating temperature -40oC to + 85oC
Models
Single output
Model
AM10EW-2403SZ
AM10EW-2405SZ
AM10EW-2412SZ
AM10EW-2415SZ
AM10EW-4803SZ
AM10EW-4805SZ
AM10EW-4812SZ
AM10EW-4815SZ
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Capacitive load
max (μF)
Efficiency
(%)
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
3.3
5
12
15
3.3
5
12
15
2
2
0.83
0.67
2
2
0.83
0.67
3300
3300
680
470
3300
3300
680
470
79
82
85
85
79
82
85
85
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Capacitive load
(μF)
Efficiency
(%)
±2200
±470
±330
±2200
±470
±330
82
85
85
82
85
85
Models
Dual output
Model
AM10EW-2405DZ
AM10EW-2412DZ
AM10EW-2415DZ
AM10EW-4805DZ
AM10EW-4812DZ
AM10EW-4815DZ
9-36
9-36
9-36
18-72
18-72
18-72
±5
±12
±15
±5
±12
±15
±1
±0.416
±0.333
±1
±0.416
±0.333
Input Specifications
Parameters
Voltage range
Nominal
24
48
Filter
Remote ON/OFF Control
ON
OFF
Turn on Transient process time
Start up time
Absolute Maximum Rating
24 Vin
48 Vin
Peak Input Voltage time
Typical
Maximum
9-36
18-72
 (Pi) Network
2.5~5.5 or open circuit
-0.7~ 0.8 or short circuit b/n pin 2 & 1
350

20
-0.7-40
-0.7-80
100
Units
VDC
VDC
ms
ms
VDC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Case/ Input & Output
Resistance
Capacitance
www.aimtec.com
F 051e R12.D
Conditions
Typical
3 sec
Rated
1500
1000
> 1000
1200
Tel: +1 514 620 2722
1 of 3
Units
VDC
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM10EW-Z
10 Watt | DC-DC Converter
Output Specifications
Parameters
Voltage accuracy
Voltage balance (Dual output)
Short Circuit protection
Short Circuit restart
Current limiting
Line voltage regulation
Load voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Rising time
Conditions
Typical
Maximum
±1
±1
Continuous
Auto Recovery
Balance Load
%
%
140
HL-LL
10-100% load
10% load
±0.5
±0.5
±1.0
±0.02
75
10
20Mhz bandwidth
Units
% of Iout max
%
%
%
%/oC
mV p-p
ms
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load
Maximum
Units
100
KHz
o
C
o
C
o
C
95
%
300
-40 to +85
-40 to +125
Free air convection
Nickel coated copper
30
g
Tolerance ±0.5mm
2.00 x 1.00 x 0.40 inches 50.80 x 25.00 x 10.16 mm
>1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency Approvals
Standards
CE, meets IEC 60950 1:2001
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
6
On/Off Control
-V Input
+V Input
-V Output
No Pin
+V Output
On/Off Control
-V Input
+V Input
-V Output
Common
+V Output
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM10EW-Z
10 Watt | DC-DC Converter
Dimensions
4
20.32
(0.80)
15.24
(0.60)
2.54
(0.10)
5
10.16
(0.40)
Bottom View
1
Notes:
All dimensions are typical
in millimeters (inches).
Tolerance ±0.25 (±0.01)
5.08
(0.20)
Min
10.16
(0.40)
DIA
1.00
(0.04)
2
10.16
(0.40)
3
7.62 5.08
(0.30) (0.20)
25.40
(1.00)
10.16
(0.40)
6
15.24
(0.60)
Built-in Stand-offs to
ease PCB cleaning
2.54
(0.10)
50.80
(2.00)
Test Circuit
Conducted Emissions
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only