AAC MS06A24T2V2 Ms low capacitance max guardâ® esd suppressor Datasheet

MS Low Capacitance MAX Guard® ESD Suppressor
The content of this specification may change without notification 10/12/07
FEATURES
•
•
•
•
HOW TO ORDER
MS
06
A
05
T
2
V2
Product
Code
Size
Tolerance
Operating
Voltage
Packaging
Typical
Clamping
Voltage
Typical
Trigger
Voltage
03: 3.3V
05: 5.5V
12: 12V
24: 24V
T: Paper
Tape
(5K/10K)
04:
0402
(1005)
06:
0603
(1608)
MAX Guard
Suppressor
A: Suit For
IEC6100-4-2
C: Suit For
IEC6100-4-2
& AEC-Q200
SCHEMATIC
1: 17V
2: 25V
Low capacitance (<0.2pF)
Ultra low leakage current (<1nA)
Fast response time
Bi-direction device
APPLICATIONS
•
•
•
•
•
V1: 150V V2:
250V
Cell / smart phone
Computers / Laptops
Digital cameras
PDA’s
Plasma display panels / LCD / TVs/
HDTVs
Mp3 / Multimedia players
Scanner / Printer
High speed data ports USB 2.0,
IEEE1394
•
•
•
DIMENSIONS (mm)
Size
L
W
C
D
T
MS04 (0402)
1.00±0.1
0.50±0.05
0.20±0.1
0.25±0.1
0.35±0.05
MS06 (0603)
1.55±0.1
0.80±0.1
0.30±0.2
0.30±0.2
0.45±0.1
ELECTRICAL CHARACTERISTICS
Type
MS04A03T1V1
MS06A03T1V1
MS04A03T2V2
MS06A03T2V2
MS04A05T1V1
MS06A05T1V1
MS04A05T2V2
MS06A05T2V2
MS04A12T2V2
MS06A12T2V2
MS06A12T1V1
MS06A12T2V2
MS04A24T2V2
MS06A24T2V2
MS06A24T1V1
MS06A24T2V2
•
•
•
•
Continuous
Operating
Voltage
(Max.)
ESD
Capability
Trigger
Voltage
(Typ.)
Clamping
Voltage
(Typ.)
150v
17v
250v
25v
150v
17v
250v
25v
150v
250v
150v
250v
150v
250v
150v
250v
17v
25v
17v
25v
17v
25v
17v
25v
Capacitance
Leakage
Current
(Typ.)
Response
Time
ESD Pulse
Withstand
(Typ.)
<0.05pF
<1nA
<1ns
>1000 pulses
3.3 VDC
5.5 VDC
12 VDC
24 VDC
Direct
Discharge:
8KV
Air
Discharge:
15KV
The function meets with the requirement of IEC 61000-4-2 specification.
Trigger measurement made using Transmission Line Pulse method.
Capacitance measured at 1 M~1.8 GHz.
Performing under IEC 61000-4-2 level 4 (8KV contact discharge, 15KV air discharge).
American Accurate Components, Inc.
188 Technology Drive, Unit H, Irvine, CA 92618
TEL: 949-453-9888 Š FAX: 949-453-8889