VDE Pending PE-RELAYS THE SLIM POWER RELAY FEATURES 5 .197 • Slim size 28 mm (L)×5 mm (W)×15 mm (H) 1.102 inch (L)×.197 inch (W)×.591 inch (H) permits high density mounting • Wide switching capacity: 100 mA/12 V DC-6A/250 V AC • High sensitivity: 170mW • High breakdown (4,000 V) and surge (6,000 V) voltage between contacts and coil • Clearance/creepage distance: 8/8 mm • 1 Form A/1 Form C contact. 28 1.102 15 .591 Insulation complying to following standards: EN 60255 General specification for electrical relays EN 60335 For use in house-hold appliances EN 60730 For use in temperature sensing appliances EN 60950 For use in electrical business equipment EN 60065 For use in entertainment electronics (radio, HiFi-sets) EN 50178 For use in industrial range SPECIFICATIONS Contacts Characteristics Arrangement 1 Form A, 1 Form C Au-plated Silver alloy silver alloy Contact material Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Nominal switching capacity Rating (resis- Maximum switching power tive) Maximum switching voltage Max. switching current Expected life Mechanical (at 180 cpm) (min.operaElectrical (at 6 cpm) tions) (at rated load) 100 mΩ 30 mΩ 6 A 250 V AC 1,500 VA 400 V AC/300 V DC 6 A (AC) 5×106 Initial insulation resistance*1 Between open contacts Initial breakdown voltage*2 Between contacts and coil Surge voltage between contacts and coil*3 Operate time*4 (at nominal voltage) Release time (without diode)*4 (at nominal voltage) N.O.: 5×104 N.C.: 3×104 Temperature rise 170 mW (4.5 to 24 V DC) 217 mW (48 V DC) Shock resistance Coil (at 25°C 77°F, 50% R.H.) Nominal operating power Destructive*6 Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Intial breakdown voltage" section *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *4 Excluding contact bounce time *5 Half-wave pulse of sine wave: 50ms; detection time: 10µs *6 Half-wave pulse of sine wave: 11ms *7 Detection time: 10µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61). TYPICAL APPLICATIONS • Interface relays for programmable controllers • Output relays for measuring equipment, timers, counters and temperature controllers • Industrial equipment, office equipment • House-hold appliances for Europe Functional*5 Functional*7 Vibration resistance Destructive Min. 1,000 MΩ at 500 V DC 1,000 Vrms 4,000 Vrms Min. 6,000 V (Initial) Max. 8 ms (approx. 5 ms) Max. 4 ms (approx. 2.5 ms) Max. 30°C with nominal coil voltage across coil and at nominal switching capacity 1 Form C: Min. 49 m/s2{5 G} 1 Form A: Min. 98 m/s2{10 G} Min. 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 1.0 mm/6 G 10 to 55 Hz at double amplitude of 1.5 mm/9 G Conditions for operation, Ambient transport and storage*8 temp. (Not freezing and condensHumidity ing at low temperature) Unit weight –40°C to +85°C –40°F to +185°F 5 to 85%R.H. Approx. 4 g .14 oz ORDERING INFORMATION Ex. APE 0 Contact arrangement Contact type Contact material Coil voltage (DC) 1: 1 Form A 3: 1 Form C 0: Single contact 0: Silver alloy 1: Au-plated silver alloy 4H: 4.5 V 18: 18 V 06: 6 V 24: 24 V 12: 12 V 48: 48 V (Notes) 1. Standard packing: Tube: 20 pcs.; Case: 1,000 pcs. 2. 5 V, 60 V type is also available. 3. 1 Form B is also available. 211 PE TYPES AND COIL DATA (at 20°C 68°F) Contact arrangement Part No. APE1004H APE10006 APE10012 APE10018 APE10024 APE10048 APE1014H APE10106 APE10112 APE10118 APE10124 APE10148 APE3004H APE30006 APE30012 APE30018 APE30024 APE30048 APE3014H APE30106 APE30112 APE30118 APE30124 APE30148 1 Form A (without Auplated) 1 Form A (with Au-plated) 1 Form C (without Auplated) 1 Form C (with Au-plated) 4.5 6 12 18 24 48 4.5 6 12 18 24 48 4.5 6 12 18 24 48 Pick-up voltage, (Initial) V DC (max.) 2.97 3.96 7.92 11.88 15.84 31.68 2.97 3.96 7.92 11.88 15.84 31.68 2.97 3.96 7.92 11.88 15.84 31.68 Drop-out voltage, (Initial) V DC (min.) 0.225 0.3 0.6 0.9 1.2 2.4 0.225 0.3 0.6 0.9 1.2 2.4 0.225 0.3 0.6 0.9 1.2 2.4 4.5 6 12 18 24 48 2.97 3.96 7.92 11.88 15.84 31.68 0.225 0.3 0.6 0.9 1.2 2.4 Nominal voltage, V DC Nominal operating current, mA (±10%) Nominal operating power, mW 38 28 14 9 7 5 38 28 14 9 7 5 38 28 14 9 7 5 170 217 170 217 170 217 38 28 14 9 7 5 170 217 Coil resistance, Ω (±10%) Max. allowable voltage, V DC 119 212 847 1,906 3,388 10,618 119 212 847 1,906 3,388 10,618 119 212 847 1,906 3,388 10,618 5.4 7.2 14.4 21.6 28.8 57.6 5.4 7.2 14.4 21.6 28.8 57.6 5.4 7.2 14.4 21.6 28.8 57.6 119 212 847 1,906 3,388 10,618 5.4 7.2 14.4 21.6 28.8 57.6 DIMENSIONS mm inch 1. 1 Form A type 15.0max. .591max. 0.5 .020 0.3 +0.2 –0.1 .012 +.008 –.004 1.2 .047 3.5 .138 2-0.5 2-.020 3.78 .149 21.42 .843 28.0max. 1.102max. 5.04 .198 2-1.0 2-.039 1.9 .075 0.4 +0.2 –0.1 .016 +.008 –.004 1.2 .047 5.0max. .197max. 3.78 .149 2-1 . 2-. 3 dia 05 . 1d ia. 2-1 . 2-.0 0 dia. 39 dia . PC board pattern (Bottom view) 21.42 .843 5.04 .198 1.2 .047 1.9 .075 Tolerance: ±0.1 ±.004 Schematic (Bottom view) General tolerance: ±0.3 ±.012 COM Coil NO 2. 1 Form C type 15.0max. .591max. 3-1 . 3-. 3 dia 05 . 1d ia. 2-1 . 2-.0 0 dia. 39 dia . PC board pattern (Bottom view) 1.2 .047 0.5 .020 0.3 +0.2 –0.1 .012 +.008 –.004 1.2 .047 3.5 .138 2-0.5 2-.020 3.78 .149 21.42 5.04 5.04 .843 .198 .198 28.0max. 1.102max. 3-1.0 3-.039 1.9 .075 0.4 +0.2 –0.1 .016 +.008 –.004 1.2 .047 5.0max. .197max. General tolerance: ±0.3 ±.012 212 5.04 5.04 .198 .198 21.42 .843 3.78 .149 1.9 .075 Tolerance: ±0.1 ±.004 Schematic (Bottom view) Coil NC COM NO PE REFERENCE DATA 2. Coil temperature rise 3. Ambient temperature characteristics Sample: APE30012 Measured portion: Inside the coil Ambient temperature: 28°C 82°F Sample: APE30012 No. of samples: n = 6 80 Temperature rise, °C 90 6 5 4 3 Contact current, A 10 2 1 0.5 0.4 0.3 0.2 10 20 30 50 100 Contact voltage, V 300 6A 0A Rate of change, % 1. Max. switching capacity 70 60 40 30 20 50 40 -40 -20 40 0 20 -10 30 20 -20 10 -30 0 Pick-up voltage 10 100 110 120 130 Coil applied voltage, %V 60 85 Drop-out voltage Ambient temperature, °C -40 NOTES Rating Standard File No. UL E43149 VDE SEV Rating 6 A 277 V AC 6 A 250 V AC (cosφ = 1) 122402ÜG 1 A 250 V AC (cosφ = 0.4) 6 A 250 V AC CH-99.1 10483.2A1 (cosφ = 1) For Cautions for Use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, 213 Ltd. Go To Online Catalog