Omron D4BL-K1 Guard lock safety-door switch Datasheet

Guard Lock Safety-door Switch
D4BL
Protective Doors Are
Locked Until Machines
Completely Stop Operating
• A mechanical lock is applied automatically when the
Operation Key is inserted. A high level of safety is
achieved using a mechanism where the lock is only
released when voltage is applied to the solenoid.
• Conforms to EN (TÜV) standards corresponding to
the CE marking.
• Approved by UL, CSA, BIA, and SUVA standards.
• The switch contact is opened by a direct opening
mechanism (NC contacts only) when the protective
cover is opened. Direct opening mechanism that is
EN-approved is indicated by
on the switch.
• Auxiliary release key ensures easy maintenance and
unlocks the door in the case of a power failure.
• Tough aluminum die-cast body incorporating a
switch box with degree of protection satisfying IP67,
UL, and CSA TYPE6P, 13.
• Equipped with a horizontal and vertical conduit opening.
• Models incorporating easy-to-see indicators for monitoring and those using an adjustable Operation Key
for a double door are available.
• The mounting direction of the head can be changed
to allow the Operation Key to be inserted from four directions.
• Metric conduit types available
Model Number Structure
Model Number Legend
Switch
D4BL -
1
2
3
4
5
1. Conduit Size (2-conduit)
1: PG13.5
2: G1/2
3: 1/2-14NPT
4: M20
4. Door Lock and Release
(Auxiliary Release Key is Incorporated by All Models)
A: Mechanical lock/24-VDC solenoid release
B: Mechanical lock/110-VAC solenoid release
G: 24-VDC Solenoid lock/Mechanical release
2. Built-in Switch (with Safety Switch and Lock Monitor
Switch Contacts)
C: 1NC/1NO (slow-action) + 1NC (slow-action)
D: 2NC (slow-action) + 1NC (slow-action)
5. Indicator
Blank: Without indicator
A:
10 to 115 VAC or VDC driving (with orange
and green LED indicator unit)
3. Head Mounting Direction
R: Four mounting directions possible (right-side mounting at
shipping)
Operation Key (Order Separately)
D4BL - K
1
1. Operation Key Type
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (Horizontal)
D-136
Safety Sensors / Components
Ordering Information
List of Models
Switches
Lock
method
Conduit
size
PG13.5
Mechanical
G1/2
lock
M20
Solenoid
lock
Pg 13.5
G1/2
M20
Voltage
for
solenoid
24 VDC
110 VAC
24 VDC
110 VAC
24 VDC
110 VAC
24 VDC
24 VDC
24 VDC
Without indicator
1NC/1NO+ 1NC
(Slow-action)
D4BL-1CRA
D4BL-1CRB
D4BL-2CRA
D4BL-2CRB
D4BL-4CRA
D4BL-4CRB
D4BL-1CRG
D4BL-2CRG
With LED indicator
1NC/1NO+ 1NC
(Slow-action)
D4BL-1CRA-A
D4BL-1CRB-A
D4BL-2CRA-A
D4BL-2CRB-A
D4BL-4CRA-A
D4BL-4CRB-A
D4BL-1CRG-A
D4BL-2CRG-A
D4BL-4CRG-A
Without indicator
2NC+ 1NC
(Slow-action)
D4BL-1DRA
D4BL-1DRB
D4BL-2DRA
D4BL-2DRB
D4BL-4DRA
With LED indicator
2NC+ 1NC
(Slow-action)
D4BL-1DRA-A
D4BL-1DRB-A
D4BL-2DRA-A
D4BL-2DRB-A
D4BL-4DRA-A
D4BL-1DRG
D4BL-2DRG
D4BL-1DRG-A
D4BL-2DRG-A
Operation Keys (Order Separately)
Mounting type
Model
Horizontal mounting
D4BL-K1
Vertical mounting
D4BL-K2
D4BL
Adjustable mounting
(Horizontal)
D4BL-K3
Specifications
Approved Standards
Agency
Standards and EC Directives
Standard
File No.
R9451050
TÜV Rheinland
EN60947-5-1
BIA
GS-ET-19
SUVA
UL
CSA
SUVA
UL508
CSA C22.2, No.14
D4BL
(Direct opening:
approved)
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN1088
Mechanical lock:
9402293
Solenoid lock:
1998 20462-01
E6186/2.d
E76675
LR45746
D-137
Approved Standard Ratings
TÜV (EN60947-5-1)
Item
Utilization category
Rated operating current (Ie)
Rated operating voltage (Ue)
Standard model
Indicator model
AC-15
AC-15
3A
6A
250 V
115 V
Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated voltage
120 VAC
240 VAC
Current
Carry current
10 A
Make
60 A
30 A
Volt-amperes
Break
6A
3A
Make
7,200 VA
Break
720 VA
Note: The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.
Characteristics
Degree of protection
Durability (See note 3.)
Operating speed
Operating frequency
Rated frequency
Operating characteristics
IP67 (See note 2.)
Mechanical:1,000,000 operations min.
Electrical:500,000 operations min. (10-A resistive load at 250 VAC)
0.05 to 0.5 m/s
30 operations/min max.
50/60 Hz
Direct opening force:19.61 N min. (EN60947-5-1)
Direct opening travel:20 mm min. (EN60947-5-1)
All stroke:23 mm min.
700 N min. (GS-ET-19)
100 MW min. (at 500 VDC)
300 V (EN60947-5-1)
Holding force
Insulation resistance
Rated insulation voltage (Ui)
Conventional enclosed thermal current
10 A (EN60947-5-1)
(Ithe)
Impulse dielectric strength (Uimp) 4 kV (EN60947-5-1) between terminals of different polarity, between each terminal and ground, and between each terminal and non-current-carrying metal
Dielectric strength (Uimp)
part;
2.5 kV between solenoid and ground (EN60947-5-1)
Conditional short-circuit current
100 V (EN60947-5-1)
Pollution degree
3 (EN60947-5-1)
(operating environment)
Protection against electric shock
Class I (with ground terminal)
Switching overvoltage
1,500 V max. (EN60947-5-1)
Contact resistance
50 mW max. (initial value)
Vibration resistance
Malfunction: 10 to 55 Hz, 0.35-mm single amplitude
Destruction:1,000 m/s2 min. (IEC68-2-27)
Shock resistance
Malfunction:300 m/s2 min. (IEC68-2-27)
Ambient temperature
Operating:–10°C to 55°C (with no icing)
Ambient humidity
Operating:95% max.
Weight
Approx. 800 g
Note: 1. The above values are initial values.
2. Although the switch box is protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals
may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
3. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%.
D-138
Safety Sensors / Components
Solenoid Coil Characteristics
Item
Rated operating voltage
Current consumption
Insulation
24-VDC mechanical lock models 110-VAC mechanical lock models
24-VAC solenoid lock models
24 VDC +10%/–15% (100% ED)
110 VAC ±10% (50/60 Hz)
24 VDC +10%/–15% (100% ED)
Approx. 300 mA
Approx. 98 mA
Approx. 300 mA
Class F (130°C or less)
Indicator Characteristics
Item
LED
Rated voltage
10 to 115 VAC/VDC
Current leakage
Approx. 1 mA
Color (LED)
Orange, green
Contact Form (Diagrams Show State with Key Inserted and Lock Engaged)
Contact
31
32
Diagram
11
23
D4BL-#C##-#
Lock position
12
24
ON
o
1NC/
1NO+1NC
Stroke
Operation Key
insertion completion position
31
32 11
21
D4BL-#D##-#
12
2NC+1NC
Lock position
ON
Stroke
Operation Key
insertion completion position
Extraction
completion
position
Only NC contacts 11-12
and 31-32 have an
approved direct
opening mechanism.
The terminals 11-12
and 23-24 can be
used as unlike poles.
Extraction
completion
position
22
Note: The EN-approved direct opening mechanism is indicated by
D4BL
Remarks
NC contacts 11-12,
21-22, and 31-32
have an approved
direct opening
mechanism.
The terminals 11-12
and 21-22 can be
used as unlike poles.
on the switch.
D-139
D4BL
Model
Connections
Indicator Unit
Internal Circuit
Dimensions
10 to 115 VAC/DC
R
Four terminal plates
Two, 7 dia. Two LED indicators
(7)
ZD
(16)
LED
R
26.8 53.2 57.2
(16)
0.3
5.6
2
Constant-current diode
10.6
(12.6)
(35)
26.2
(61.2)
Circuit Connection Example
• Do not connect the indicators to the safety contact terminals (1112-31-32) or the safety circuit side.
• When using indicators, connect them to the auxiliary circuit side
(monitor circuit) or the solenoid input terminals as shown below.
• The indicators can be used to confirm the open/closed status of the
door, the ON/OFF status of the power supply, and the ON/OFF status of the solenoid.
• Do not connect the indicators in parallel with the direct opening
contact. If the indicators are broken, a short-circuit current may
flow, causing equipment to malfunction.
• The 24-VDC solenoid terminals have polarity. Confirm the polarity
before wiring.
• Be sure to use a special pushbutton switch to stop and start
machinery and release locks.
1. Orange: Lights when the solenoid turns ON.
Green: Lights when the door opens.
2. Orange: Lights when the solenoid turns ON.
Green: Lights when power turns ON.
(Power supply side)
(Power supply side)
E1 (+)
11
12
31
32
E1 (+)
11
12
31
32
Solenoid
23
24
LED (orange)
Solenoid
E2 (−)
23
24
LED (orange)
LED (green)
Auxiliary circuit
(monitor circuit)
Safety circuit
LED (green)
Auxiliary circuit
(monitor circuit)
(Ground side)
3. Orange: Lights when the solenoid turns ON.
Green: Lights when door closes.
Safety circuit
(Ground side)
4. Orange: Lights when the solenoid turns ON.
Green: Lights when power turns ON.
(Power supply side)
(Power supply side)
E1 (+)
E1 (+)
11
12
31
11
32
12
31
32
Solenoid
21
22
LED (orange)
Solenoid
E2 (−)
21
22
LED (orange)
LED (green)
Auxiliary circuit
(monitor circuit)
D-140
Safety circuit
(Ground side)
E2 (−)
E2 (−)
LED (green)
Auxiliary circuit
(monitor circuit)
Safety circuit
(Ground side)
Safety Sensors / Components
Nomenclature
D4BL-#C##-#
D4BL-#D##-#
Operation Key
Lock plate
Operation Key
Lock plate
Auxiliary release key
Lock monitor switch
Solenoid
Auxiliary release key
Rotating drum
Rotating drum
Lock monitor switch
Solenoid
Operation plunger
Operation plunger
Seal ring (NBR)
Auxiliary plunger
Seal packing (NBR)
Rotating lever
Seal ring (NBR)
Auxiliary plunger
Seal packing (NBR)
Rotating lever
Safety switch
Safety switch
Seal packing (NBR)
Seal packing (NBR)
Conduit opening
Connection
(Pull out
terminal M3.5
horizontally)
Ground terminal M3.5
Conduit opening
Conduit opening
(Pull out
(Pull out
horizontally)
vertically)
Connection
terminal M3.5
Conduit opening
(Pull out
vertically)
Ground terminal M3.5
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Switches
D4BL-####-#
Four, M3.5 head
clamping screws
(116.5)
15
34.2
37.5
Four, 5.3 dia.
mounting
holes
Four, M4
cover
clamping
screws
Cover
(123.5)
74±0.1
6.8
Conduit opening
7
Lock
protection
cap
100±0.1
112+1
0
Indicators
5.5
D4BL
31.5
17
10
Red
86+10
16
39.6
46.3
Conduit opening
Operating Characteristics
D4BL-####
Key insertion force
19.61 N max.
Key extraction force
19.61 N max.
Movement before being locked 15 mm max.
D4BL
D-141
Operation Keys
Horizontal Mounting
Vertical Mounting
D4BL-K1
D4BL-K2
Red
Red
53.7
78.7
40.7
12
20±0.15
Long mounting hole
13
5.3 x 7.3 long mounting hole
7.3 15
25.8 15.6
25.8 15.6
40±0.15 52.4
Two, 2.65R
36
5.3
5.3
2.6
7.5
36
5.3 11.9 7.5
20
11.8
20
11.8
5.6
5.6
4 dia.
4 dia.
2.6
Adjustable Mounting (Horizontal)
D4BL-K3
40
Red
12
20
26
(80.7)
40
Red
36
30±0.15
2.6
11.8
30
19.5±0.1
(37.8)
5.6
5.3 dia.
17.5
4 dia.
D-142
34.6
M4 Allen-head bolt
Safety Sensors / Components
With Operation Key Inserted
Horizontal Mounting
D4BL + D4BL-K1
Red
Horizontal direction
Operation Key insertion radius
R ≥ 1200
53.5 min. 57 max.
(41)
(20±0.15)
(12)
Vertical direction
Operation Key insertion radius
R ≥ 1000
53.5 min. 57 max.
(20±0.15)
(41)
(35)
Vertical direction
Operation Key insertion radius
R ≥ 1000
Vertical Mounting
D4BL + D4BL-K2
Horizontal direction
Operation Key insertion radius
R ≥ 1200
Red
54.5 min. 58 max.
(41)
54.5 min. 58 max.
(13)
(41)
(40±0.15)
D4BL
(35)
Adjustable Mounting (Horizontal)
D4BL + D4BL-K3
Vertical direction
Operation Key insertion radius
R ≥ 1000
Red
Horizontal direction
Operation Key insertion radius
R ≥ 250
81.5 min. 85 max.
81.5 min. 85 max.
(41)
(41)
(40)
(30±0.15)
(35)
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. In the above diagrams, the Operation Key is inserted from the front.
D4BL
D-143
Precautions
Stopper
Caution
Do not insert the Operation Key to the Switch with the door open.
Before using the machine, be sure to remove the shock-absorbing
damper, which is provided before shipping. Otherwise the machine may start operating and injury may be caused.
Stopper
Mount the Operation Key at a location where it will not come in contact with users when the door is opened or closed.
When operating the D4BL as a part of a safety circuit or an emergency stop circuit to prevent injury, operate the NC contacts that
have a direct opening mechanism in direct opening mode. For safety
purposes, tighten the switch body and Operation Key with one-way
screws or equivalents or install a switch protection cover and warning label for safety purposes to prevent easy removal of the D4BL.
Switch
Do not use the Switch as
a stopper. When mounting
the Switch, be sure to locate a stopper as shown
in the following illustration
to prevent the top of the
Operation Key from hitting
the switch head.
Connect the fuse to the D4BL in series to prevent it from short-circuit
damage. The value of the breaking current of the fuse must be calculated by multiplying rated current by 150% to 200%.
When using the D4BL with EN ratings, use 10-A fuse Type gI or gG
that complies with IEC60269.
In order to prevent the D4BL from burning due to overvoltage, insert
a protection fuse into the solenoid circuit.
If the D4BL is imposed with force exceeding the lock strength, the
D4BL may break and the equipment may continue to operate.
Correct Use
Auxiliary Release Key
Due to the wear and tear of the sealing of the D4BL, water and some
types of oil and chemical sprayed onto the D4BL may cause contact
or insulation failures, current leakages, or fires.
The auxiliary release key is used to unlock the D4BL in case of
emergency or in case the power supply to the D4BL fails.
Use an appropriate tool to set the auxiliary release key to UNLOCK
so that the lock will be released and the door can be opened.
LOCK
Operating Environment
Do not use the D4BL in the following locations.
•
•
•
•
Locations subject to severe temperature changes
Locations subject to high temperatures or condensation
Locations subject to severe vibration
Locations where the product may come in contact with metal dust,
oil, or chemicals
UNLOCK
Auxiliary
release key
The auxiliary release key applied to the door of a machine room
ensures the safety of people adjusting the equipment in the machine
room. If the auxiliary release key is set to UNLOCK, the door will not
be locked when the door is closed and no power will be supplied to
the equipment.
To lock the door, set the auxiliary release key to LOCK.
Operation Key
The D4BL is provided with a shock-absorbing damper to protect the
D4BL from damage that may result from dropping the D4BL during
transportation. Be sure to remove the damper after mounting the
D4BL.
The mounting tolerance of the Operation Key is ±0.3 mm vertically or
horizontally. Be sure to mount the D4BL correctly without leaning,
otherwise the D4BL may soon break or wear out.
Do not use the auxiliary release key to start or stop machines.
To prevent the auxiliary release key from being handled carelessly by
unauthorized people, seal the auxiliary release key with sealing wax
and the provided seal cap to ensure IP67.
±0.3 min.
Make sure that the auxiliary release key is kept with the person in
charge.
Before attaching the cover to the D4BL, make sure that the auxiliary
release key position is set to LOCK.
±0.3 min.
Do not drop the D4BL with the Operation Key inserted, otherwise the
Operation Key may deform or break.
D-144
Safety Sensors / Components
Two, M5 Operation Key mounting screw
Four, M3.5 head-mounting screw
Four, M4 cover-mounting screw
Drop
The head is constructed so that it cannot be operated with tools such
as screwdrivers. Always use OMRON’s Operation Key to operate the
head in order to ensure the safety of the machine and protect the
D4BL from damage.
Four, M5
switch-mounting
screw
Conduit
Conduit cap
The Operation Key provided for the D4BL is not compatible with that
of the D4BS.
Switch and Operation Key Mounting
Mount the Operation Key and secure it with one-way screws or
equivalents to prevent easy removal of the D4BL.
Mount the D4BL and Operation Key with four M5 screws with washers and tighten each screw to the specified torque.
Securing the Door
Mounting Dimensions
If the Operation Key on the closed door is pulled outside the set zone
by a force caused by vibration, the door’s weight, or the door cushion
rubber, the D4BL may be damaged. Secure the door with hooks so
that it will remain within the set zone.
Switch Mounting Dimensions
Four, M5
Space
D4BL
74±0.1
100±0.1
Set zone
Operation Key Mounting Holes
• Horizontal Mounting
D4BL-K1
Two, M5
Tightening Torque
Be sure to tighten each screw of the D4BL properly, otherwise the
D4BL may malfunction.
1
2
3
4
5
6
7
Type
M3.5 terminal screw
(including terminal screw)
Cover mounting screw
Head mounting screw
M5 body mounting screw
Operation Key mounting screw
Connector
Cap screw
20±0.1
• Vertical Mounting
D4BL-K2
Torque
Two, M5
0.59 to 0.78 N·m
1.18 to 1.37 N·m
0.78 to 0.98 N·m
4.90 to 5.88 N·m
2.35 to 2.75 N·m
1.77 to 2.16 N·m
1.27 to 1.67 N·m
40±0.1
• Adjustable Mounting (Horizontal)
D4BL-K3
Two, M5
30±0.1
D4BL
D-145
Head Directions
The head can be mounted in four directions. To remove the head,
turn the head by 45° as shown in figures A and B below.
To change the direction of the head, make sure that the protruding
part of the rotating lever engages with the groove of the plunger.
Then turn the head clockwise or counterclockwise to the desired
direction. At that time, make sure that the groove of the plunger is
located under the rotating lever. If the direction of the head is not set
when the plunger is rotated by 45°, the groove of the plunger presses
the rotating lever. The head, plunger, or the built-in switch may be
damaged as a result.
Head Direction Changes
Left
Front
(45∞)
(45∞)
(A)
(B)
Back
Right
Head Bottom View
Operation plunger and
groove mechanism
Switch Top View
Rotation lever and
protruding part
Normal Positions of Rotating Lever and Plunger
Switch body
Rotating lever (with
protruding part)
Plunger (with groove)
Built-in switch
Be sure to check the mechanical lock and solenoid release functions
when mounting the D4BL.
If the head direction is changed, recheck the tightening torque of
each of screw. Make sure that no foreign materials will penetrate
through the key hole on the head.
Mounting the Cover
When tightening the cover, first check the specified torque, and then
tighten each screw to the that torque. Also, make sure that no foreign
matter has entered the switch.
When mounting the cover, make sure that the cover and switch box
are properly aligned.
D-146
Safety Sensors / Components
Processing and Connecting Cable/Conduit
The following procedures are recommended for mounting and wiring
the indicator unit securely.
In order to ensure IP67, use OMRON’s SC-#M and Nippon Flex’s
ABS-08Pg13.5 and ABS-12 Pg13.5 Connectors.
Cable Connection Example
1. Connect the wires to the terminals in the order shown below for
wiring efficiency.
Recommended cable: UL2464-type cable that is 20 to 18 AWG (0.5
to 1.0 mm2) in size and has seven conductors
If the 1/2-14NPT is used, cover the cable and conduit end with sealing tape in order to ensure IP67. Tighten the connector to a torque of
1.77 to 2.16 N·m.
Connect the indicator unit after connecting the seven-conductor
cable.
Tighten each wired terminal clockwise to a torque of 0.59 to
0.78 N·m.
Twist the wire two or three times and make sure that no bare wire
exists outside the terminal when tightening the terminal.
Lp (mm)
30±2
35±2
45±2
55±2
65±2
70±2
Lv (mm)
80±2
75±2
60±2
50±2
45±2
35±2
90±2
50±2
a (mm)
2. The insulation sheath of the seven-conductor cable must come
into contact with the wall of the conduit mouth, side A or side B.
8±1
Properly attach and securely tighten the provided conduit cap to the
unused conduit opening when wiring the D4BL.
D4BL
Terminal no.
E1
E2
31
12
23 (21)
24 (22)
Insulation sheath edge
Maintenance and Repairs
Contact your OMRON representative for any repair or maintenance
work on the D4BL. The D4BL must not be maintained or repaired by
any unauthorized party.
Others
Do not touch the solenoid because the solenoid radiates heat while
power is being supplied.
D4BL