SELECTION GUIDE
Input
Order code
FEATURES
◆RoHS compliant
Output
Voltage(VDC)
Voltage
(VDC)
Current(MA)
Max
Min
Efficiency
(%,Typ)
Switching
Frequency
(KHz,Typ)
Nominal
Range
IB0505XS-2W
5
4.75-5.25
5
400
40
70
100
IB0515XS-1W5
5
4.75-5.25
15
100
10
75
97
IB1205XS-2W
12
11.4-12.6
5
400
40
71
55
IB1505XS-2W
15
14.25-15.
5
400
40
71
67
IB2405XS-2W
24
22.8-25.2
5
400
40
71
67
◆Efficiency up to 84%
◆SIP Package
◆Wide temperature performance at full
2 Watt load,-40°C to 85°C
◆UL 94V-0 package material
◆No heatsink required
◆Small Footprint
◆Industry standard pinout
◆Power sharing on output
ISOLATION SPECIFICATIONS
◆1KVDC isolation
◆Continuous Short Circuit Protection
◆Internal SMD construction
Parameter
Test conditions
Min.
Isolation test voltage
Flash tested for 1 minute and 1mA max
1000
Typ.
Max.
Units
VDC
Isolation resistance
Test at Viso=500VDC
1000
MΩ
◆No external components required
◆MTTF up to 1.5 million hours
MODEL SELECTION
IB①05②05③X④ S⑤-2W⑥
①Product Series
③Output Voltage
⑤SIP Package
②Input Voltage
④Fixed Input
⑥Rated Power
OUTPUT SPECIFICATIONS
APPLICATIONS
Parameter
Test conditions
Min
Typ.
Max.
Units
The IB_XS-2W series are specially designed for applications
where a group of polar power supplies are isolated from the
Output power
1
W
input power supply in a distributed power supply system on a
Line regulation
For Vin change of ±5%
±0.25
%
Load regulation
10% to 100% full load
±1.5
%
100% full load
±3
%
circuit board.
These products apply to:
1) where the voltage of the input power supply is fixed
(voltage variation ≤±5%);
2) where isolation is necessary between input and output
0.2
Output voltage accuracy
Temperature drift
(isolation voltage ≤1000VDC);
Output Ripple*
3) where the regulation of the output voltage and the output
Output Noise*
100% full load
0.03
%/°C
20
30
MV p-p
20MHz Bandwidth
50
100
MV p-p
Full load,nominal input
100
20MHz Bandwidth
ripple noise are demanded.
Switching frequency
Khz
* Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing of Power
Converter section, application notes.
MICRODC reserves the copyright
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 2
IB-XS-2W Series
Recommended circuit
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Storage humidity range
Operating temperature
-40
Storage temperature
Lead temperature
-55
1.5mm from case for 10 seconds
20
Temp.rise at full load
Max.
Units
95
%
85
°C
125
°C
30
°C
300
°C
Cooling
Free air convection
Case material
Plastic(UL94-V0)
If you want to further decrease the input/output ripple,
an "LC" filtering network may be connected to the input
and output ends of the DC/DC converter, see (Figure 1).
Continuous
Short circuit protection
1
MTBF
S
3500
K hours
Weight
2.8
g
*Supply voltage must be discontinued at the end of short circuit duration.
TYPICAL CHARACTERISTICS
Temperature Derating Graph
It should also be noted that the inductance and the
frequency of the "LC" filtering network should be
staggered with the DC/DC frequency to avoid mutual
interference. However, the capacitance of the output
filter capacitor must be proper. If the capacitance is too
big, a startup problem might arise. For every channel of
output, provided the safe and reliable operation is
ensured, the greatest capacitance of its filter capacitor
sees (Table 1).
EXTERNAL CAPACITOR TABLE (TABLE 1)
Cin
Vout
Vin
Cout
(VDC)
5
(μF)
4.7
(VDC)
5
(μF)
4.7
12
2.2
-
-
15
1.0
-
-
24
0.47
-
-
It's not recommend to connect any external capacitor in
the application field with less than 0.5 watt output.
Overload Protection
OUTLINE DIMENSIONS & PIN CONNECTIONS
Under normal operating conditions, the output circuit of
these products has no protection against over-current
and short - circuits . The simplest method is to connect a
self-recovery fuse in series at the input end or add a
circuit breaker to the circuit.
SIZE Graph
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
Input Over-voltage Protection Circuit
The simplest device for input over-voltage protection is
a linear voltage regulator with overheat protection that is
connected to the input end in series (Figure 2).
FOOTPRINT DETAILS
Pin
Note:
Unit:mm(inch)
Pin section:0.50*0.3mm(0.020*0.012inch)
Pin section tolerances:±0.10mm(±0.004inch)
General tolerances:±0.25mm(±0.010inch)
Function
1
VIN
2
GND
4
0V
6
+V0
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise
specified.Another 24V products, please inquire Our technical department!
Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum output load is
not less than 10% of the full load, and that this product should never be operated under no load! If the
actual output power is very small, please connect a resistor with proper resistance at the output end in
parallel to increase the load.or use our company's products with a lower rated output power .
When the environment temperature is higher than 71°C,
the product output power should be less then 60% of the
rated power.
No parallel connection or plug and play.
Use dual output simultaneously, forbid opening output
pin (0V) to use as single output.
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646
REACH COMPLIANT INFORMATION
E-mail:[email protected]
Website:http://www.microdc.cn
http://www.microdc.cn
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 2
Similar pages