Cooper LD1-120-R Metalized drum core power inductor Datasheet

LD Series
Metalized Drum Core Power Inductor
Applications
• Buck or boost inductor
• Noise filtering and output filter chokes
• Computers
• Power supplies
• Test equipment instrumentation
Environmental Data
• Storage temperature: -40°C to +125°C
• Operating temperature: -40°C to +125°C (range is application
specific). Temperature rise is approximately 40°C at rated rms
current.
• Solder reflow temperature: 260°C max. for 10 seconds max.
Packaging
• Supplied in tape and reel packaging, LD1 (2,000),
LD2 (1,000) parts per reel
Description
• Metalized drum core design utilizes board space
• Current Range from 4.46 amps to 0.52 amps
• Inductance range from 1.0µH to 470µH
• Ferrite core material
Part
Number
LD1-1R0-R
LD1-1R4-R
LD1-1R8-R
LD1-2R2-R
LD1-2R7-R
LD1-3R3-R
LD1-3R9-R
LD1-4R7-R
LD1-5R6-R
LD1-6R8-R
LD1-8R2-R
LD1-100-R
LD1-120-R
LD1-150-R
LD1-180-R
LD1-220-R
LD1-270-R
LD1-330-R
LD1-390-R
LD1-470-R
LD1-560-R
LD1-680-R
Rated
Inductance
(µH)
1.0
1.4
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
12
15
18
22
27
33
39
47
56
68
OCL(1)
Nominal
Irms(2)
Amps
Isat(3)
Amps
1.00
1.40
1.80
2.20
2.70
3.30
3.90
4.70
5.60
6.80
8.20
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
2.66
2.47
2.35
2.22
2.11
2.00
1.75
1.57
1.51
1.41
1.32
1.13
1.05
0.99
0.83
0.78
0.67
0.66
0.63
0.52
0.50
0.46
4.46
3.41
3.05
2.76
2.52
2.32
2.14
2.00
1.75
1.56
1.41
1.28
1.18
1.05
0.98
0.89
0.87
0.75
0.68
0.61
0.57
0.52
Notes:
1) Open Circuit Inductance Test Parameters: 100kHz, 0.25Vrms, 0.0Adc
+/-20% except for LD1-330-R to LD1-331-R and LD2-470-R to LD2-471-R which is +/-10%
2) RMS current for an approximate ∆T of 40°C. It is recommended that the temperature of the
part not exceed 125°C
3) Peak current for an approximate 10% rolloff at 20°C
1207
BU-SB07325
Page 1 of 3
4) DCR limits @ 20°C
5) Part number definition: LDx-yyy-R
LDx = product code and size, -yyy = inductance value in µH,
R = decimal point. If no R is present, third character = # of zeros
-R suffix = RoHS compliant
Data Sheet 4310
DCR(4)
(Ω)
(Max.)
0.0330
0.0380
0.0420
0.0470
0.0520
0.0580
0.0760
0.0940
0.1010
0.1170
0.1320
0.1820
0.2100
0.2350
0.3380
0.3780
0.5220
0.5400
0.5870
0.8440
0.9370
1.12
Part
Number
Rated
Inductance
(µH)
82
100
150
220
330
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
LD1-820-R
LD1-101-R
LD1-151-R
LD1-221-R
LD1-331-R
LD2-100-R
LD2-120-R
LD2-150-R
LD2-180-R
LD2-220-R
LD2-270-R
LD2-330-R
LD2-390-R
LD2-470-R
LD2-560-R
LD2-680-R
LD2-820-R
LD2-101-R
LD2-121-R
LD2-151-R
LD2-181-R
LD2-221-R
LD2-271-R
LD2-331-R
LD2-391-R
LD2-471-R
OCL(1)
Nominal
Irms(2)
Amps
Isat(3)
Amps
82
100
150
220
330
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
82
100
120
150
180
220
270
330
390
470
0.43
0.36
0.29
0.26
0.22
3.83
3.57
3.38
3.19
3.13
2.81
2.70
2.42
2.25
1.96
1.88
1.63
1.53
1.43
1.23
1.15
1.00
0.94
0.83
0.78
0.74
0.50
0.45
0.40
0.33
0.30
3.45
3.20
2.85
2.60
2.45
2.10
2.01
1.85
1.64
1.50
1.35
1.28
1.15
1.09
0.95
0.87
0.79
0.73
0.64
0.58
0.55
Notes:
1) Open Circuit Inductance Test Parameters: 100kHz, 0.25Vrms, 0.0Adc
+/-20% except for LD1-330-R to LD1-331-R and LD2-470-R to LD2-471-R which is +/-10%
2) RMS current for an approximate ∆T of 40°C. It is recommended that the temperature of the
part not exceed 125°C
3) Peak current for an approximate 10% rolloff at 20°C
DCR(4)
(Ω)
(Max.)
1.28
1.72
2.68
3.42
4.70
0.0700
0.0800
0.0900
0.1000
0.1100
0.1200
0.1300
0.1600
0.1800
0.2400
0.2800
0.3700
0.4300
0.4700
0.6400
0.7100
0.9600
1.11
1.26
1.77
1.96
4) DCR limits @ 20°C
5) Part number definition: LDx-yyy-R
LDx = product code and size, -yyy = inductance value in µH,
R = decimal point. If no R is present, third character = # of zeros
-R suffix = RoHS compliant
Dimensions - mm
Recommended Pad Layout
Top View
A
Bottom View
Front View
Schematic
C
xxx
B
H
1
I
Marking
G
I
Component Side
Marking:
LD1: xxx=inductance value
per family chart
LD2: "C" logo
xxx=inductance value
1207
BU-SB07325
Dimensions
A
+/-0.3
B
+/-0.3
C
+/-0.3
G
ref
H
ref
I
ref
LD1
4.5
4.0
3.2
1.5
4.5
1.75
LD2
7.8
7.0
5.0
2.0
7.5
3.0
Page 2 of 3
Data Sheet 4310
2
Packaging Information
8.0
LD1 Series
Supplied in tape and reel packaging,
2000 parts per reel, 13" diameter reel.
ACTUAL SIZE
LD1
xxx
xxx
xxx
xxx
12.0
User Direction Feed
LD2 Series
12.0
Supplied in tape and reel packaging,
1000 parts per reel, 13" diameter reel.
ACTUAL SIZE
LD2
xxx
xxx
xxx
xxx
16.0
User Direction Feed
Inductance Characteristics
OCL vs Isat
LD2
100
100
90
90
80
80
70
70
OCL (%)
OCL (%)
OCL vs Isat
LD1
60
50
40
60
50
40
30
30
20
20
10
10
0
0
0
10
20
30
40
50
60
70
80
90
100
110
120
% of Isat
North America
Cooper Bussmann
1225 Broken Sound Parkway NW
Suite F
Boca Raton, FL 33487-3533
Tel: 1-561-998-4100
Fax: 1-561-241-6640
Toll Free: 1-888-414-2645
Cooper Bussmann
P.O. Box 14460
St. Louis, MO 63178-4460
Tel: 1-636-394-2877
Fax: 1-636-527-1607
0
10
20
30
40
50
60
70
80
90
100
110
120
% of Isat
Europe
Cooper Bussmann
Cooper (UK) Limited
Burton-on-the-Wolds
Leicestershire • LE12 5TH UK
Tel: +44 (0) 1509 882 737
Fax: +44 (0) 1509 882 786
Cooper Bussmann
Avda. Santa Eulalia, 290
08223
Terrassa, (Barcelona), Spain
Tel: +34 937 362 812
+34 937 362 813
Fax: +34 937 362 719
Asia Pacific
Cooper Bussmann
1 Jalan Kilang Timor
#06-01 Pacific Tech Centre
Singapore 159303
Tel: +65 278 6151
Fax: +65 270 4160
This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice,
to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any
technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the
Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling,
can be reasonably expected to result in significant injury to the user.
© 2007 Cooper Bussmann
S t . L o u i s, M O 6 3 1 7 8
w w w. c o o p e r bu s s m a n n . c o m
1207
BU-SB07325
Page 3 of 3
Data Sheet 4310
Similar pages