Technical Data1010 Effective February 2016 Supersedes July 2013 Fusetron™ FRN-R Class RK5 250Vac, 125/250Vdc 70-600A, dual element, time-delay fuses Catalog numbers (amps) FRN-R-70 FRN-R-125 FRN-R-350 FRN-R-75 FRN-R-150 FRN-R-400 FRN-R-80 FRN-R-175 FRN-R-450 FRN-R-85 FRN-R-200 FRN-R-500 FRN-R-90 FRN-R-225 FRN-R-600 FRN-R-100 FRN-R-250 FRN-R-110 FRN-R-300 Carton Quantity: Catalog symbols: • FRN-R-_ Description: Eaton Bussmann® series advanced protection, energy efficient FRN-R Class RK5 dual element, current-limiting, time-delay fuses. Time-delay – 10 seconds (minimum) at 500% of rated current. Specifications: Volts • 250Vac • 125Vdc (110-200A) • 250Vdc (225-600A) • Amps 70-600A • Interrupting rating • 200kA Vac RMS Sym. • 20kA Vdc Agency information • UL Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273 • CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787 • CE Carton qty. 70 – 100 5 110 – 600 1 Features: • Provides motor overload, ground fault and short-circuit protection • Helps protect motors against burnout from overloads and single-phasing when sized properly • Simplifies and improves blackout prevention (selective coordination) • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection • The overload element provides protection against low level overcurrent of overloads and will hold on inrush current which is five times greater than the amp rating of the fuse for a minimum of ten seconds Ratings • Amp rating FRN-R Class RK5 250Vac, 125/250Vdc 70-600A, dual element, time-delay fuses Technical Data 1020 Effective February 2016 Dimensions - in: 5.88” 1.06” 70 to 100A 7.13” 1.56” 110 to 200A 8.63” ± 0.09 2.38” ± 0.02 225 to 400A 10.38” ± 0.09 2.88” ± 0.02 450 to 600A Recommended fuse blocks: Fuse amps 1-pole 2-pole 3-pole 70-100 RM25100-1CR RM25100-2CR RM25100-3CR 110-200 RM25200-1CR RM25200-2CR RM25200-3CR 225-400 RM25400-1CR RM25400-2CR RM25400-3CR 450-600 RM25600-1CR RM25600-2CR RM25600-3CR For additional information on the RM 250 volt fuse blocks, see product brochure no. 3192. use reducers for Class R fuses Fuse size 65 to 100A 110 to 200A Amp size of fuse block or disconnect switch 400A 65 to 100A 110 to 200A Catalog no. (pairs) No.2641-R* No.242-R* No.2661-R* 600A 225 to 400A No.2662-R* No.2664-R*† * These reducers are not CSA Certified. † Single reducer only (pair not required) For additional information on Class R fuse reducers, see data sheet no 1118. 2 Eaton.com/bussmannseries FRN-R Class RK5 250Vac, 125/250Vdc 70-600A, dual element, time-delay fuses Technical Data 1020 Effective February 2016 Time-current curves — average melt: 600 400 200 100 Time in seconds 60 Amp rating Current in amps Eaton.com/bussmannseries 3 FRN-R Class RK5 250Vac, 125/250Vdc 70-600A, dual element, time-delay fuses Technical Data 1020 Effective February 2016 Current-limitation curves: Current-limiting effects: B 400000 Prosp. S.C.C. 300000 INSTANTANEOUS PEAK-LET-THROUGH CURRENT IN AMPS — 100A 200A 400A 5000 3000 5000 5000 5000 10,000 4000 7000 10,000 10,000 15,000 5000 8000 11,000 15,000 600A 20,000 5000 8000 12,000 16,000 400A 25,000 6000 9000 13,000 17,000 200A 30,000 6000 10,000 14,000 18,000 35,000 6000 10,000 15,000 19,000 40,000 7000 11,000 15,000 20,000 50,000 7000 11,000 17,000 21,000 60,000 8000 12,000 18,000 22,000 70,000 8000 13,000 19,000 23,000 80,000 8000 13,000 19,000 24,000 AMP RATING 200000 100000 90000 80000 70000 60000 50000 40000 30000 Let-through current (apparent RMS Sym. vs. fuse rating) 100A 20000 10000 9000 8000 7000 6000 5000 600A 90,000 9000 14,000 20,000 25,000 4000 100,000 9000 14,000 21,000 26,000 3000 150,000 10,000 16,000 24,000 29,000 200,000 11,000 18,000 26,000 32,000 A 2000 200000 50000 60000 70000 80000 90000 100000 40000 30000 20000 4000 5000 6000 7000 8000 9000 10000 3000 2000 1000 1000 RMS SYMMETRICAL CURRENT IN AMPS A-B = ASYMMETRICAL AVAILABLE PEAK (2.3 X SYM RMS AMPS) The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries © 2016 Eaton All Rights Reserved Printed in USA Publication No. 1020 — BU-SB13731 February 2016 Eaton, Bussmann and Fusetron are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. Follow us on social media to get the latest product and support information.