XP Power DCU348S15 Dc-dc pcb mount Datasheet

DC-DC PCB Mount
1-25 Watts
THE XPERTS IN POWER
DCU Series
•
Fully Isolated Outputs
•
2:1 Input Range
•
Metal Case
•
Surface Mount Construction
•
DIN Rail Mount Option
•
Screw Terminals Option
•
Remote ON/OFF Available
Specification
Input
General
Input Voltage
•
4.5-9.0 VDC, 9-18 VDC,
18-36 VDC, 36-72 VDC
•
•
See Table
±5% DCU15 & 25 models only
(3 V models 3.20 to 3.47 V)
No minimum load required
20 ms max
+5% -3% max
+5%, DCU 5 V output
±60 mV max
0.5% max (0.1% typical)
1% max single output models
(0.2% typical)
5% max dual output models
(1.0% typical)
40 mV p-p typical, 150 mV max.
(the addition of a 100 µF (220 µF
for 3 & 5 V outputs) capacitor across
output of device reduces ripple to
below 40 mV pk-pk
DCU15 & 25 models only - operates
115-140% of output (3 V models
4.0-5.25 V)
Operates >105% of rating and
recovers automatically
±0.02%/°C
Output
Output Voltage
Output Voltage
Adjustment
Minimum Load
Start Up Delay
Initial Set
Accuracy
Drift
Line Regulation
Load Regulation
Ripple & Noise
•
•
•
•
•
•
•
Overvoltage
Protection
•
Short Circuit &
Overload Protection
Temperature
Coefficient
Remote ON/OFF
•
•
•
Efficiency
Lead Temperature
Isolation
•
•
•
67% to 85% dependant on model
+260°C for less than 15 seconds
500 VAC Input to Output,
500 VAC Input to Ground,
500 VAC Output to Ground
Environmental
Operating
Temperature
Storage
Temperature
Shock
•
Vibration
•
•
•
-20 °C to +70 °C
See Derating Curve
-40 °C to +85 °C
50 G for 11 ms,
once on each X, Y & Z axis
10 G 10-55 Hz 3 mins period,
60 mins along X, Y & Z axis
EMC & Safety
Emissions
•
ESD Susceptability
Radiated
Susceptability
EFT/Burst
Surge
Safety Approvals
•
•
EN55022 Level A Conducted
with external components
EN55022 Level A Radiated
EN61000-4-2 Level 4
EN61000-4-3 Level 3
•
•
•
EN61000-4-4 Level 3
EN61000-4-5 Level 3
EN60950, UL1950, cUL1950
DCU15 & 25 models only - link RC
to -ve I/P for operation (or TTL low),
open circuit for shutdown
(or TTL high)
•
•
www.xpplc.com
[email protected]
OUTPUT VOLTAGE & CURRENT RATINGS - SINGLE OUTPUT MODELS
Input
(V)
Output
Model No. DCU105S05
Input Voltage
DCU105S15
DCU112S05
Output
12 V @ 0.13 A 15 V @ 0.1A
5 V @ 0.3 A
5 V @ 0.3 A
Model No. DCU305S05
Output
5 V @ 0.6 A
Input Voltage
4.5 - 9 Volts
DCU105S12
DCU305S12
9 - 18 Volts
DCU305S15
DCU312S05
12 V @ 0.25 A 15 V @ 0.2 A
5 V @ 0.6 A
DCU112S12
Input Voltage
18 - 36 Volts
DCU112S15
12 V @ 0.13 A 15 V @ 0.1 A
DCU312S12
DCU
Input Voltage
DCU312S15
12 V @ 0.25 A 15 V @ 0.2 A
DCU124S05
DCU124S12
36 - 75 Volts
DCU124S15
DCU148S05
5 V @ 0.3 A 12 V @ 0.13 A 15 V @ 0.1 A
5 V @ 0.3 A
DCU324S05
DCU324S12
DCU148S12
DCU148S15
12 V @ 0.13 A 15 V @ 0.1 A
DCU324S15
DCU348S05
5 V @ 0.6 A 12 V @ 0.25 A 15 V @ 0.2 A
5 V @ 0.6 A
DCU348S12
DCU348S15
12 V @ 0.25 A 15 V @ 0.2 A
Model No. DCU605S05
DCU605S12
DCU605S15
DCU612S05
DCU612S12
DCU612S15
DCU624S05
DCU624S12
DCU612S15
DCU648S05
DCU648S12
DCU648S15
Output
12 V @ 0.5 A
15 V @ 0.4 A
5 V @ 1.2 A
12 V @ 0.5 A 15 V @ 0.4 A
5 V @ 1.2 A
12 V @ 0.5 A
15 V @ 0.4 A
5 V @ 1.2 A*
12 V @ 0.5 A
15 V @ 0.4 A
5 V @ 1 A*
Model No. DCU1005S05 DCU1005S12 DCU1005S15 DCU1012S05 DCU1012S12 DCU1012S15 DCU1024S05 DCU1024S12 DCU1024S15 DCU1048S05 DCU1048S12 DCU1048S15
Output
5 V @ 1.6 A*
12 V @ 0.7 A
15 V @ 0.6 A
Model No. DCU1505S05 DCU1505S12
-
Output
-
5 V @ 2 A*
12 V @ 1 A
Model No. DCU2505S05 DCU2505S12
-
Output
-
5 V @ 3.2 A*
12 V @ 1.7 A
5V@2A
12 V @ 0.9 A 15 V @ 0.7 A
DCU1512S05 DCU1512S12
5 V @ 2.4 A
-
12 V @ 1.3 A
-
DCU2512S05 DCU2512S12
-
5V@4A
12 V @ 2.1 A
5V@2A
12 V @ 0.9 A
DCU1524S05 DCU1524S12
5 V @ 2 A*
12 V @ 0.9 A
15 V @ 0.7 A
-
DCU1548S05 DCU1548S12
12 V @ 1.3 A
-
5 V @ 2.4 A*
12 V @ 1.3 A
-
DCU2524S05 DCU2524S12
-
DCU2548S05 DCU2548S12
-
5 V @ 2.4 A
-
15 V @ 0.7 A
5V@4A
12 V @ 2.1 A
-
5 V @ 4 A*
-
12 V @ 2.1 A
-
Note
•
* Also available with 3.3 V output, current rating is the same as the 5 V model except for the DCU25 where the 3.3 V is rated at 4.0 A.
Replace ‘S05’ with ‘S03’ in the model number to order.
OUTPUT VOLTAGE & CURRENT RATINGS - MULTI OUTPUT MODELS
Input
(V)
Output
Model No.
Output
Model No.
Output
Model No.
Output
Model No.
Output
Model No.
Output
Model No.
Output
Input Voltage
Input Voltage
4.5 - 9 Volts
DCU
Input Voltage
9 - 18 Volts
Input Voltage
18 - 36 Volts
36 - 75 Volts
DCU105D12
DCU105D15
DCU112D12
DCU112D15
DCU124D12
DCU124D15
DCU148D12
DCU148D15
±12 V(24) @ 0.065 A
±15 V(30) @ 0.05 A
±12 V(24) @ 0.065 A
±15 V(30) @ 0.05 A
±12 V(24) @ 0.065 A
±15 V(30) @ 0.05 A
±12 V(24) @ 0.065 A
±15 V(30) @ 0.05 A
DCU305D12
DCU305D15
DCU312D12
DCU312D15
DCU324D12
DCU324D15
DCU348D12
DCU348D15
±12 V(24) @ 0.13 A
±15 V(30) @ 0.1 A
±12 V(24) @ 0.13 A
±15 V(30) @ 0.1 A
±12 V(24) @ 0.13 A
±15 V(30) @ 0.1 A
±12 V(24) @ 0.13 A
±15 V(30) @ 0.1 A
DCU605D12
DCU605D15
DCU612D12
DCU612D15
DCU624D12
DCU624D15
DCU648D12
DCU648D15
±12 V(24) @ 0.25 A
±15 V(30) @ 0.2 A
±12 V(24) @ 0.25 A
±15 V(30) @ 0.2 A
±12 V(24) @ 0.25 A
±15 V(30) @ 0.2 A
±12 V(24) @ 0.25 A
±15 V(30) @ 0.2 A
DCU1005D12
DCU1005D15
DCU1012D12
DCU1012D15
DCU1024D12
DCU1024D15
DCU1048D12
DCU1048D15
±12 V(24) @ 0.35 A
±15 V(30) @ 0.3 A
±12 V(24) @ 0.45 A
±15 V(30) @ 0.35 A
±12 V(24) @ 0.45 A
±15 V(30) @ 0.35 A
±12 V(24) @ 0.45 A
±15 V(30) @ 0.35A
DCU1505D12
DCU1505D15
DCU1512D12
DCU1512D15
DCU1524D12
DCU1524D15
DCU1548D12
DCU1548D15
±12 V(24) @ 0.6 A
±15 V(30) @ 0.5 A
±12 V(24) @ 0.65 A
±15 V(30) @ 0.5 A
±12 V(24) @ 0.65 A
±15 V(30) @ 0.5 A
±12 V(24) @ 0.65 A
±15 V(30) @ 0.5 A
DCU2505D12
DCU2505D15
DCU2512D12
DCU2512D15
DCU2524D12
DCU2524D15
DCU2548D12
DCU2548D15
±12 V(24) @ 0.84 A
±15 V(30) @ 0.67 A
±12 V(24) @ 1.05 A
±15 V(30) @ 0.85 A
±12 V(24) @ 1.05 A
±15 V(30) @ 0.85 A
±12 V(24) @ 1.05 A
±15 V(30) @ 0.85 A
Application Notes
Temperature Derating
Output trim (±5%) DCU15 & 25 models
Note: if output set too high
OVP may operate
O/P
VR1
5V
1 kΩ
100 Ω 270 Ω
R1
R2
12 V
5 kΩ
270 Ω 2.7 kΩ
±12 V
5 kΩ
10 kΩ 3.9 kΩ
±15 V
5 kΩ
10 kΩ 2.7 kΩ
Mounting Accessories
DCU-BOARD
The DCU-BOARD is designed to accept any of the DCU Series, it provides screw terminals and has provision for the trim resistors for the DCU15 and
25 watt models. It can be supplied with a DIN HOUSING for mounting on DIN rails - both top hat and G types.
www.xpplc.com
[email protected]
Mechanical Details - 1.5 to 6 Watt Models
DCU1
*Not fitted on single output models
❅ Recommended size for
processing PWB
*COM
VIEW A
VIEW B
Weight 10g
DCU3
*Not fitted on single output models
❅ Recommended size for
processing PWB
*COM
VIEW A
VIEW B
Weight 16g
DCU6
*Not fitted on single output models
❅ Recommended size for
processing PWB
*COM
VIEW A
VIEW B
Weight 25g
www.xpplc.com
[email protected]
Mechanical Details - 10 to 25 Watt Models
DCU10
❅ Recommended size for
processing PWB
*COM
Weight 40g
*Not fitted on single output models
❅ Recommended size for
processing PWB
DCU15
Weight 55g
*Not fitted on single output models.
N.B. Link RC to -ve I/P for operation (or TTL Low), O/C for shutdown (or TTL High)
*Tolerance: ±0.5
*Dimensions in mm.
❅ Recommended size for
processing PWB
DCU25
Weight 65g
*Not fitted on single output models.
N.B. Link RC to -ve I/P for operation (or TTL Low), O/C for shutdown (or TTL High)
www.xpplc.com
*Tolerance: ±0.5
*Dimensions in mm.
[email protected]
Rev 3.0