Vicor MEGAPAC User- and field-configurable power supply Datasheet

MegaPAC™ Family
AC-DC and DC-DC Switchers
User- and Field-Configurable Power Supplies
Features & Benefits
PFC MegaPAC-EL/HPEL
15.6 x 6.0 x 3.4in
[396.2 x 152.4 x 86.4mm]
Up to 2400W at 230VAC
1 – 16 Outputs (8 Slots)
• AC inputs available: 85 – 264VAC,
208 / 240VAC 3-Phase
• Power factor corrected
(some models)
• Up to 4kW
• DC inputs available: 100 – 380VDC
• User and field configurable
• Compact sizes as small as
3.4 x 6.0 x 9.5in
[86.4 x 152.4 x 241.3mm]
• Fan cooled
• Efficiency >80%
• Up to 20 regulated outputs
(up to 10 slots) from 1 to 95VDC and above
• Full power to 45°C on most products
• OVP, OTL, OCP on most outputs
• Autosense
PFC MegaPAC/HP
12.3 x 6.0 x 3.4in
[312.4 x 152.4 x 86.4mm]
Up to 2400W at 230VAC
1 – 16 Outputs (8 Slots)
• Power fail warning
• Sequencing and general shut down
• Agency approved cTÜVus, CE Marked
• Current Sharing
• Low leakage option available
(some models)
Product Description
The MegaPAC family of products offers four different versions of user configurability
to meet almost any set of input and output requirements. Leveraging Vicor modular
DC-DC converters, MegaPAC family products combine feature-laden front ends with
slide-in output assemblies called ConverterPACs.
User configurability is at the heart of every MegaPAC. A wide variety of the same
length ConverterPACs™ can be installed, exchanged or removed with the turn of just
one screw. This means the MegaPAC can be reconfigured to meet evolving power
requirements. Given its range of configurability, the MegaPAC is appropriate for
virtually any application from prototype through production.
MegaPAC™ Family
Page 1 of 10
Rev 1.6
03/2016
MegaPAC™ Family
MegaPAC Family
Model
Dimension
Input Voltage
Output Power
Number of
Outputs
ConvertPACs™
Per Slot
Mini MegaPAC™
9.5 x 6.0 x 3.4in
[241.3 x 152.4 x 86.4mm]
90 – 132 /
180 – 264VAC Strappable
260 – 380VDC
1,000W @ 115VAC
or 230 Vac
1 – 10
(5 slots)
ModuPAC™, JrPAC™,
DualPAC™, RamPAC™,
BatPAC™
15.6 x 6.0” x 3.4in
[396.2 x 152.4 x 86.4mm]
85 – 264VAC
100 – 380VDC
1,200W @ 115VAC
2,400W @ 230VAC
1 – 16
(8 slots)
QPAC™, DualQPAC™,
JrQPAC™, FinQPAC™ [b]
(FinQPAC requires 2 slots)
PFC MegaPAC/HP™
12.3 x 6.0 x 3.4in
[312.4 x 152.4 x 86.4mm]
85 – 264VAC
100 – 380 Vdc
2,400W @ 230VAC
1,200W @ 115VAC
1 – 16
(8 slots)
ModuPAC, JrPAC,
DualPAC, RamPAC,
BatPAC, FinPAC™ [a]
(FinPACs require 2 slots)
4kW MegaPAC™
14.0 x 7.5 x 4.9in
[355.6 x 190.5 x 124.5mm]
208 or 240VAC
Three Phase
260 – 352VDC
4,000W – 3 phase
1 – 20
(10 slots)
ModuPAC, JrPAC,
DualPAC, RamPAC,
BatPAC, UniPAC™ [b]
PFC MegaPAC-EL/HPEL™
[a]
[b]
[a]
Low noise ripple for EL power supplies is 10mVP-P or 0.15% whichever is greater.
ConverterPACs with Maxi module
MegaPAC Configuration
DC-DC Converter
At the heart of every MegaPAC are Vicor zero-current switching, DC-DC
converters. The modularity of the design combined with the breadth of the
product line means virtually any output voltage can be provided.
ConverterPAC
ConverterPACs are the slide-in output assemblies that allow each MegaPAC
to be easily configured to user-specified output requirements. Using the
Vicor DC-DC converter, up to 600W of output power can be provided
per ConverterPAC. Larger power needs are easily handled by paralleling
ConverterPACs.
MegaPAC
Each MegaPAC houses an array of user-selected ConverterPACs to provide a
customized power supply. Using a different front end for each product line,
almost any input power can be accommodated. The result is a customized
power supply with off-the-shelf delivery.
MegaPAC™ Family
Page 2 of 10
Rev 1.6
03/2016
MegaPAC™ Family
Performance Specifications
Typical at 25ºC, nominal line and 75% load, unless otherwise specified
Parameter
PFC MegaPAC™, PFC MegaPAC-HP™,
PFC MegaPAC-HPEL™, PFC MegaPAC-EL™
Mini MegaPAC™
4kW MegaPAC™
115 – 230VAC, Strappable
208 / 240VAC, 3-phase, 4 wire
180 – 264VAC 1-phase
Input Charactersitics
Input
85 – 264VAC
Standard Line
Vantage Line
47 – 500Hz
47 – 63Hz
100 – 380VDC
260 – 380VDC
Line Regulation
Inrush Current
0.2% max from 10% to full load
25APK at 115VAC
80APK at 115 and 230VAC
25APK at 230VAC
Ride-Through Time
Power Factor
30APK at 230VAC
>20ms at nominal line, full load
Power Fail
Conducted EMI
(47 – 63Hz)
260 – 352VDC
>3ms warning
EN 55022 Level B (certain configurations)
FCC B
0.99 (115VAC)
0.98 (230VAC)
Surge Immunity
(Common Mode & Normal Mode)
EN 55022 Level A
EN 55022 Level A
0.65
0.92 (3-phase operation)
EN 61000-4-5 Class 3, Performance Critera B
Output Charactersitics
Load Regulation
0.2% max from 10% to full load
0.5% from no load to 10% load
Standard Line:1.0% for standard voltages, 2.0% for special or adjustable voltages
Set-Point Accuracy
Vantage Line: 2.0% for standard voltages, 5.0% for special or adjustable voltages
See Vicor module specifications.
A preload may be necessary for modules trimmed down below 90% of normal output voltage.
Standard outputs: 2% or 100mVP-P max whichever is greater, 10% minimum load
Ripple and Noise
(20MHz BWL)
VXI options: 50mVP-P max for outputs, ≤15VDC; 150mVP-P max. 15V < VOUT ≤ 24V; 1% VOUT > 24V
2nd Generation QPAC, FinPAC, FinQPAC and UniPAC performance dependent on the converter module used.
(Output of module is unfiltered.)
QPAC, DualQPAC, JuniorQPAC, RamPAC: 10mVP-P max or 0.15%, whichever is greater.
Overcurrent Protection
Overvoltage Protection
Efficiency
105 –130% > 5V outputs
30 – 125% ≤ 5V outputs
ModuPACs and QPACs: 115 – 135%
80% typical
82% typical
1,600W at 40°C (230VAC)
PFC MegaPAC; PFC MegaPAC-EL (Low Noise)
Output Power
2,400W at 40°C (230VAC)
PFC MegaPAC HP, PFC MegaPAC HPEL
1,200W at 40°C (115VAC) PFC MegaPACs
MegaPAC™ Family
Page 3 of 10
Rev 1.6
03/2016
82% typical
4,000W at 45°C (3-phase)
1,000W at 45°C (115 / 230VAC)
1,500W at 45°C (1-phase)
MegaPAC™ Family
Performance Specifications (Cont.)
Typical at 25ºC, nominal line and 75% load, unless otherwise specified
PFC MegaPAC™, PFC MegaPAC-HP™,
PFC MegaPAC-HPEL™, PFC MegaPAC-EL™
Parameter
Mini MegaPAC™
4kW MegaPAC™
Environmental
Storage Temperature
Operating Temperature
–40 to +85ºC
[c]
Vantage Line Full Power
0 to +40ºC
0 to +45ºC
0 to +45ºC
Vantage Line Half Power
0 to +60ºC
0 to +65ºC
0 to +65ºC
Standard Line Full Power
–20 to +40ºC
–20 to +45ºC
–20 to +45ºC
Standard Line Half Power
–20 to +60ºC
–20 to +65ºC
–20 to +65ºC
Safety Agency Approvals
cTÜVus
CE Marked for Low Voltage Directive and RoHS Recast Directive, as applicable
9.75lbs [4.43kg] (PFC MegaPAC & HP)
Product Weight (Fully Configured)
12.8lbs [5.8kg] (PFC MegaPAC EL)
6.25lbs [2.84kg]
22.0lbs [10kg]
13.0lbs [6.0kg] (PFC MegaPAC HPEL)
Limited Warranty
[c]
2 Years
PFC MegaPACs: The maximum operating temperature is 40°C. If using a VI-200™ with output voltage <12V and >150W, the operating temperature
decreases to 35°C. This also applies when using a FinPAC™ with output voltage <24V and >500W. Mini MegaPAC & 4kW MegaPACs: The operating
temperature is 45°C using any combination of modules and output voltages as long as the front-end rating is not exceeded. Normal derating applies to half
power if the ambient temperature is 20°C hotter.
MegaPAC™ Family
Page 4 of 10
Rev 1.6
03/2016
MegaPAC™ Family
ConverterPAC™ Overview
nn
Output voltages from 2 – 95VDC
nn
Autosense / Remote Sense
nn
Output power up to 600W
nn
Low noise option:10mVP-P or 0.15%,
whichever is greater
nn
DC OK
nn
Adjustment ranges from
50% to 110% of nominal
nn
80 – 90% efficiency
nn
Current source outputs available
MegaPAC Configuration for MegaPAC Family Product
Converters
Module(s) Used
Maximum Output Power
VE-200 and VE-J00 ConverterPACs
ModuPAC™
(M) (RoHS – GM)
1 VE-200 DC-DC Converter
Up to 200W per ConverterPAC
RamPAC™
(R) (RoHS – GR)
1 VE-J00 DC-DC Converter
1 Ripple Attenuator Module (VI-RAM)
Up to 100W for applications requiring low ripple / noise
DualPAC™
(D) (RoHS – GD)
2 VI-J00™ DC-DC Converters
Dual Output; Up to 100W each output
JuniorPAC™
(J) (RoHS – GJ)
1 VI-J00 DC-DC Converter
Up to 100W
BatPAC™
(B) (RoHS – GB)
1 VI-200™ BatMod
A 200W programmable current source that can be
configured as a battery charger
QPAC™ [d]
Low Noise
(L) (RoHS – GL)
1 VI-200 DC-DC Converter
with differential- and common-mode filters
Up to 200W for applications requiring as low as
10mVP-P output noise
JrQPAC™ [d]
Low Noise
(LJ) (RoHS – GLJ)
1 VE-J00 DC-DC Converter
with differential- and common-mode filters
Up to 100W
DualQPAC™ [d]
Low Noise
(LD) (RoHS – GLD)
2 VI-J00 DC-DC Converters
with differential- and common-mode filters
Dual Output; Up to 100W each output
Maxi ConverterPACs
[d]
[e]
UniPAC™
(XU) (RoHS – GXU)
1 Maxi DC-DC Converter
Up to 500W; Applicable for 3-phase / 4kW product
FinPAC™ [e]
(PZ) (RoHS – GPZ)
1 Maxi DC-DC Converter
Up to 600W; Applicable for PFC MegaPAC High Power
FinQPAC™ [e]
(PZL) (RoHS – GPL)
1 Maxi DC-DC Converter
with discrete output filter
Up to 600W; Applicable for PFC MegaPAC-HPEL
Only for the extended-length MegaPACs
FinPACs and FinQPACs require two (2) slots.
MegaPAC™ Family
Page 5 of 10
Rev 1.6
03/2016
MegaPAC™ Family
MegaPAC Mechanical Drawings
Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details.
PFC MegaPAC™ / PFC MegaPAC-High Power™
12.24 (310,82)
3.37 (85,60)
CUSTOMER MOUNTING HOLES (16X)
M4 OR #8-32 THREAD MAXIMUM
SCREW PENETRATION .150 (4.00 MM)
FROM OUTSIDE SURFACE.
0.25 (6,35)
3.275 (83,19)
0.41 (10,35)
D
1.458 (37,03)
FAN
(DIRECTION OF AIR
1600001 057
L1
47 TO 500 Hz
L2
300VDC
INPUTS
115/230 VAC
0.729 (18,52)
0.470 (11,94)
DO NOT
OPERATE
WITHOUT
EARTH
GROUND
LABEL NO: 94-00046 REV B
NOTE: SET SCREW MAXIMUM
TORQUE = 4.4 INCH POUNDS
MP6-78600
5.100 (129,54)
0.47 (11,94)
CLAMPING SCREWS
2.75 (69,85)
14 AWG WIRE
L1
5.10 (129,5)
7 SP. @ 0.7285 (18,5)
PFC
MegaPAC
FLOW OPTIONAL)
6.04 (153,42)
6.75 (171,45)
0.64 (16,31)
1.40 (35,56)
1/4 - 20 SERRATED FLANGED
NUT ZINC PLATED STEEL
WITH OPTIONAL BUSS BARS
2.77 (70,23)
L2
DO NOT
OPERATE
WITHOUT
EARTH
GROUND
INPUTS
115/230 VAC
47 TO 500 Hz
300VDC
6.75 (171,45)
2.49 (63,17)
NOTE: SET SCREW MAXIMUM
TORQUE = 4.4 INCH POUNDS
LABEL NO: 94-00046 REV B
2.92 (74,17)
0.21 (5,33)
11.93 (302,90)
PFC MegaPAC-EL™ (Low Noise)
15.090 (383,29)
0.250 (6,35)
CUSTOMER MOUNTING HOLES (4X)
M4 OR #8-32 THREAD MAXIMUM
SCREW PENETRATION 0.150 (4,00)
FROM OUTSIDE SURFACE.
3.275 (83,19)
0.41 (10,35)
3.37 (85,60)
PFC
MegaPAC-EL
FAN
(DIRECTION OF AIR
FLOW OPTIONAL)
5.100 (129,54)
6.04 (153,42)
7 SP. @ 0.7285 (18,5)
= 5.10 (129,5)
47 TO 500 Hz
L2
300VDC
INPUTS
115/230 VAC
L1
0.470 (11,94)
DO NOT
OPERATE
WITHOUT
EARTH
GROUND
LABEL NO: 94-00046 REV B
NOTE: SET SCREW MAXIMUM
TORQUE = 4.4 INCH POUNDS
0.729 (18,52)
0.470 (11,94)
0.64 (16,32)
1/4 - 20 SERRATED FLANGED
NUT ZINC PLATED STEEL
WITH OPTIONAL BUSS BARS
CLAMPING SCREWS
14 AWG WIRE
L1
10.010 (254,25)
L2
INPUTS
115/230 VAC
47 TO 500 Hz
300VDC
DO NOT
OPERATE
WITHOUT
EARTH
GROUND
NOTE: SET SCREW MAXIMUM
TORQUE = 4.4 INCH POUNDS
2.920 (74,17)
LABEL NO: 94-00046 REV B
0.210 (5,33)
15.185 (385,70)
CUSTOMER MOUNTING HOLES (4X)
M4 OR #8-32 THREAD MAXIMUM
SCREW PENETRATION 0.150 (4,00)
FROM OUTSIDE SURFACE.
MegaPAC™ Family
Page 6 of 10
Rev 1.6
03/2016
2.487 (63,18)
1.40 (35,56)
2.77 (70,23)
MegaPAC™ Family
MegaPAC Mechanical Drawings
Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details.
Mini MegaPAC™
DO NOT LOOSEN OR
TIGHTEN INNER NUTS
8.78 (223,0)
3.38 (85,8)
0.60 (15,2)
J10 (PIN 1)
1/4 - 20 ZINC PLATED STEEL,
SERRATED FLANGED NUTS
45 IN-LBS ±5
M4/#8-32 THDS 16 PLACES
MAX SCREW PENETRATION - 0.15
1.80 (45,7)
J2-PIN1
+P5
TYP.
-P5 TYP.
J2B-PIN1
(SAME AS J2)
R4 "TRIMPOT" PRESENT
WHEN ADJUSTABLE OUTPUT
OPTION IS SPECIFIED.
Mini
MegaPAC
6.04 (153,4)
5.10 (129,5)
3.52 (89,4)
1
LABEL LOCATED
APPROXIMATELY
AS SHOWN (TYP)
(MODUPAC MODEL NO.)
CLAMPING SCREWS FOR INPUT LEADS,
MAXIMUM TORQUE 10 IN-LBS
0.040 X 0.13 SLOT
INPUT LEGEND
L2
230 VAC
AS IS
-OR115 VAC
WITH S1-S2
JUMPER
1.93 (49,0)
0.45 (11,4)
0.20 SQ. (5.2 MM) OPENINGS (J9-1
THRU J9-5) FOR #10 AWG INPUT WIRES
0.50 (12,7)
L1/N
J3-PIN1
+P1
TYP.
1.06 (26,9)
S2
J1A-PIN1
(DUAL MOD)
AIR BLOCK
(EXAMPLE)
1.19 (30,2)
J9-1
2.91 (73,9)
4=SP. @ 0.7285 (18,5)
R12
J1B-PIN1
(DUAL MOD)
J9-5
S1
J2A-PIN1
(SAME AS J2)
R4
DUAL MODUPAC
(NO "POWER GOOD"
OPTION AVAILABLE)
1.40 (35,6)
0.62 (15,7)
LABEL LOCATED
APPROXIMATELY
AS SHOWN
-P1
TYP.
2.74 (69,6)
4.800 (121,8)
DO NOT
RUN W/O
EARTH
GROUND
HERE.
FAN
MODUPAC REMOVAL
STANDARD
(SCALE: NONE)
AIR FLOW
#4-40 CAPTIVE SCREWS
TO SECURE/REMOVE
MODUPACS, 5 PLACES
2.920 (74,2)
9.10 (231,3)
0.220 (5,6)
9.40 (238,8)
4kW MegaPAC™
1/4 - 20 ZINC PLATED STEEL,
SERRATED FLANGED NUTS
45 IN-LBS ±5
(OUTER NUT ONLY)
DO NOT LOOSEN OR
TIGHTEN INNER NUTS
AMP NO. 746862-2 PLUG
FOR FLAT RIBBON CABLE
MATES WITH HSG AMP NO.
747547-2 PLUS SLIDE
LATCH OR SIMILAR.
2 J2-PIN1
(16X) M4/#8-32 TAPPED HOLE
.15 MAX. PENETRATION
0.560 (14,2)
+P8
TYP.
0.40 (10,2)
-P8 TYP.
BUS BARS - FOR
PARALLEL OUTPUTS
4kW
MegaPAC
R4 "TRIMPOT" PRESENT
WHEN ADJUSTABLE OUTPUT
OPTION IS SPECIFIED
J2B-PIN1
(SAME AS J2)
7.50 (190,5)
1.852 (47,0)
(12X) 1/8 X 1/2 SLOTS
R12
J2A-PIN1
(SAME AS J2)
6.56 (166,6)
9=SP. @ .7285 (18,5)
1.852 (47,0)
L1 L2 L3
AIR BLOCK
(EXAMPLE)
1.20 (30,5)
0.240 (6,1)
R4
DUAL MODUPAC
(NO "POWER GOOD"
OPTION AVAILABLE)
5.10 (129,5)
J1B-PIN1
(DUAL MOD)
#4-40 CAPTIVE SCREWS
J1A-PIN1
TO SECURE MODUPACS
(DUAL
MOD)
10 PLACES
1
BUS BAR - FOR
SERIES OUTPUTS
J3-PIN1
2.068 (52,5)
1.20 (30,5)
0.46 (11,7)
2.25 (57,2)
4.90 (124,5)
6.75 (171,5)
LABEL LOCATED
APPROXIMATELY
AS SHOWN
+P1
TYP.
LABEL LOCATED
APPROXIMATELY
AS SHOWN (TYP)
(MODUPAC MODEL NO.)
MODUPAC REMOVAL
1.40 (35,6)
4.00 (101,6)
0.65 (16,5)
2.25 (57,2)
6.75 (171,5)
11.95 (303,5)
1.64 (41,8)
MegaPAC™ Family
Page 7 of 10
12.28 (311,9)
Rev 1.6
03/2016
0.54 (13,7)
1.15 (29,2)
0.25 (6,35)
STANDARD AIR FLOW
-P1
TYP.
0.31 X 1.25 AMP
MegaPAC™ Family
Connection Diagrams – Input
PFC MegaPAC™
PFC MegaPAC-High Power™
PFC MegaPAC-EL™
PFC MegaPAC-HPEL™
Mini MegaPAC™
INPUT CONNECTIONS
J9
INPUT CONNECTIONS
J9
J9-5 120VAC
J9-4 120VAC
J9-3 L1/N
J10
3
7
8
9
J1-1 Line 3
J1-2 Line 2
4
J1-3 Line 1
J1-4 Earth Ground
J9-1 Earth Ground
J10 Interface
J10-1
E/D-1
J10-2
E/D-2
J10-3
E/D-3
J10-4
E/D-4
J10-5
E/D-5
J10-6
N/C
J10-7
N/C
J10-8
N/C
J10-9
VCC +5V, 0.3A
J10-10
Signal Ground
J10-11
AC Power OK
J10-12
General Shutdown
E/D-1
E/D-2
E/D-3
E/D-4
E/D-5
E/D-6
E/D-7
E/D-8
Vcc +5V, 0.3A
Signal Ground
AC Power OK
General Shutdown
2
INPUT CONNECTIONS
J1
Jumper for
115V operation
J9-2 AC Hot
J9-1 Earth Ground
1
}
J9-3 AC Neutral
J9-2 L2
J10 Interface
J10-1
J10-2
J10-3
J10-4
J10-5
J10-6
J10-7
J10-8
J10-9
J10-10
J10-11
J10-12
4kW MegaPAC™
5
Housing-Molex P/N: 39-01-2120
Terminal-Molex P/N: 39-00-0039
Crimp Tool-Molex P/N: 11-01-0197
6
10 11 12
J10
1
2
3
7
8
9
4
5
6
10 11 12
J10 Interface
1 Signal Ground
2 Signal Ground
3 Overtemp. Warning
4 Analog Temperature
5 General Shutdown
6 No Connection
7 Enable/Disable #10
8 Enable/Disable #8
9 Enable/Disable #6
10 Enable/Disable #4
11 Enable/Disable #2
12 Signal Ground
13 Gate In Slot #1 (isolated)
Molex header Mini-fit Jr. 12 POS #39-30-1120
Customer I/O interface mating receptacle
Molex #39-01-2120with terminal #39-00-0039
and 18-24 AWG str anded wire.
Use Molex tool #11-01-0197
1
2 3 4
5 6
14 Phase Fail Warning
15 Signal Ground
16 Vcc +5 volt, 300 mA
17 Vcc +5 volt, 300 mA
18 AC Power OK
19 AC Power Fail
20 Enable/Disable #9
21 Enable/Disable #7
22 Enable/Disable #5
23 Enable/Disable #3
24 Enable/Disable #1
25 Gate Out Slot #10 (isolated)
7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
Amp 25 pin connector #841-17-DBFR-DA25P
plug for flat ribbon cable. Mates with
housing ADAM TECH #DB25-SR-SL
and contacts #DCS-01B plus slide latch
#HDW-043-25.
Connection Diagrams – Output
ModuPAC™
JuniorPAC™
RamPAC™
DualPAC™
MODUPAC, JRPAC, RAMPAC
+V0UT
J2-PIN1
0UTPUT ADJUST
–VOUT
J3-PIN1
DUALPAC
J2 (REMOTE SENSE)
1
2
3
MATING HARDWARE
HOUSING- MOLEX P/N: 50-57-9403
TERMINALS- MOLEX P/N: 16-02-0103
CRIMP TOOL MOLEX P/N: 63811-8700
TRIM PIN ACCESS
+SENSE
–SENSE
J3 DC OK (POWER GOOD)
4
3
2
1
VCC IN
POWER GOOD
POWER GOOD INVERTED
SIGNAL GROUND
MATING HARDWARE
HOUSING- MOLEX P/N: 50-37-5043
TERMINALS- MOLEX P/N: 08-70-1040
CRIMP TOOL MOLEX P/N: 63811-5200
J1-B-PIN1
J2-B-PIN1
OUTPUT ADJUST
J1-A-PIN1
J2-A-PIN1
OUTPUT ADJUST
J1 (OUTPUT CONNECTORS)
4 1
5 2
6
3
MATING HARDWARE
HOUSING- MOLEX P/N: 50-57-9403
TERMINALS- MOLEX P/N: 16-02-0103
CRIMP TOOL MOLEX P/N: 11-01-0208
J2 (REMOTE SENSE)
1 TRIM PIN ACCESS
2 + SENSE
3 –SENSE
BatPAC™
FinPAC™
FINPAC
BATPAC
+ V0UT
CURRENT LIMIT ADJUST
VOLTAGE LIMIT ADJUST
P2 REMOTE SENSE T
RIM/SC & POWER GOOD
J2 (BATPAC REMOTE INTERFACE)
4
3
2
1
+ VOUT
CURRENT LIMIT ADJUST
VOLTAGE LIMIT ADJUST
CURRENT MONITOR
– VOUT
OUTPUT ADJUST
–VOUT
– VOUT
J2-PIN1
MegaPAC™ Family
Page 8 of 10
MATING HARDWARE
HOUSING- MOLEX P/N: 39-01-2060
1 AND 4 +VOUT
2 AND 5 –VOUT
TERMINALS- MOLEX P/N: 39-00-0039
3 +R/SENSE 6 –R/SENSE CRIMP TOOL MOLEX P/N: 11-01-0197
MATING HARDWARE
HOUSING- MOLEX P/N: 50-37-5043
TERMINALS- MOLEX P/N: 08-70-1040
CRIMP TOOL MOLEX P/N: 63811-5200
P2-PIN1
Rev 1.6
03/2016
7
6
5
4
3
2
1
+SENSE
–SENSE
TRIM
VCC IN
POWER GOOD
POWER GOOD INVERTED
SIGNAL GROUND
MATING HARDWARE
HOUSING- MOLEX P/N: 50-37-5073
TERMINALS- MOLEX P/N: 08-70-1040
CRIMP TOOL MOLEX P/N: 63811-5200
MegaPAC™ Family
Connection Diagrams – Output (Cont.)
QPAC™
JuniorQPAC™
QPAC (L), JrQPAC
(LJ)
DualQPAC™
DUAL QPAC
P2 REMOTE SENSE TRIM/SC
& POWER GOOD
+VOUT
OUTPUT ADJUST
–VOUT
7
6
5
4
3
2
1
7
6
5
4
3
2
1
TRIM TOP
TRIM BOT
N/C
VCC IN
POWER GOOD
POWER GOOD INVERTED
SIGNAL GROUND
J1-A-PIN1
MATING HARDWARE
HOUSING- MOLEX P/N: 50-37-5073
TERMINALS- MOLEX P/N: 08-70-1040
CRIMP TOOL MOLEX P/N: 63811-5200
P2-PIN1
J1-B (OUTPUT CONNECTORS)
J1-B-PIN1
+SENSE
–SENSE
TRIM
VCC IN
POWER GOOD
POWER GOOD INVERTED
SIGNAL GROUND
4
1
5
2
6
3
1 AND 4 +VOUT
2 AND 5 –VOUT
3 +R/SENSE 6 –R/SENSE
MATING HARDWARE
HOUSING- MOLEX P/N: 39-01-2060
TERMINALS- MOLEX P/N: 39-00-0039
CRIMP TOOL MOLEX P/N: 11-01-0197
J1-A (OUTPUT CONNECTORS) MATING HARDWARE
4
1
5
2
6
3
1 AND 4 +VOUT
2 AND 5 –VOUT
3 +R/SENSE 6 –R/SENSE
HOUSING- MOLEX P/N: 39-01-2060
TERMINALS- MOLEX P/N: 39-00-0039
CRIMP TOOL MOLEX P/N: 11-01-0197
FinQPAC™
FINPAC
P2 REMOTE SENSE T
RIM/SC & POWER GOOD
+ VOUT
OUTPUT ADJUST
–VOUT
7
6
5
4
3
2
1
+SENSE
–SENSE
TRIM
VCC IN
POWER GOOD
POWER GOOD INVERTED
SIGNAL GROUND
MATING HARDWARE
HOUSING- MOLEX P/N: 50-37-5073
TERMINALS- MOLEX P/N: 08-70-1040
CRIMP TOOL MOLEX P/N: 63811-5200
P2-PIN1
ConverterPAC™ Options
Option
ModuPAC™ BatPAC™ DualPAC™ JuniorPAC™ RamPAC™ DualQPAC™ QPAC™ JuniorQPAC™ UniPAC™ FinPAC™ FinQPAC™
(M)
(B)
(D)
(J)
(R)
(LD)
(L)
(LJ)
(XU)
(PZ) [f]
(PLZ) [f]
OPT
NA
NA
OPT
OPT [i]
OPT [i]
OPT
OPT
OPT
OPT
OPT
T Trim:
+10%/–10%
OPT [g]
NA
OPT
OPT [g]
OPT [g]
NA
OPT [g]
OPT
OPT
OPT
OPT
F Trim:
+10%/–50%
OPT [g]
NA
OPT
OPT [g]
OPT [g]
NA
OPT [g]
OPT
OPT
OPT
OPT
V1 VXI Low Noise
(150mVP-P
15V < VOUT ≤ 24V)
OPT
NA
OPT
OPT
NA [h]
NA [h]
NA [h]
NA [h]
NA
NA
NA [h]
V2 VXI Low Noise
(50mVP-P ≤ 15V)
OPT
NA
OPT
OPT
NA
NA
NA
NA
NA
NA
NA
V3 VXI Low Noise
(1% VOUT > 24V)
OPT
NA
OPT
OPT
NA
NA
NA
NA
NA
NA
NA
Parallelable
STD
STD
NA
NA
NA
NA
STD
NA
STD
STD
STD
Autosense
STD
NA
STD
STD
NA
STD
STD
STD
STD
STD
STD
D Power Good
[f]
FinPACs and FinQPACs require two slots.
[g] Module dependent, 3.3V, 10 – 15V “T” option only.
[h] All QPACs and RamPACs have output ripple of 10mV
P-P or 0.15% whichever is greater.
[i] Per slot-based indicator.
MegaPAC™ Family
Page 9 of 10
Rev 1.6
03/2016
MegaPAC™ Family
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/megapac for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Contact Us: http://www.vicorpower.com/contact-us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
www.vicorpower.com
email
Customer Service: [email protected]
Technical Support: [email protected]
©2018 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
All other trademarks, product names, logos and brands are property of their respective owners.
MegaPAC™ Family
Page 10 of 10
Rev 1.6
03/2016
Similar pages