MORNSUN F1215XT-1WR2 Dc/dc converter Datasheet

DC/DC Converter
F_XT-1WR2 series
1W, Fixed input voltage , isolated & unregulated single
output
FEATURES
l
l
l
l
l
l
l
l
Continuous short circuit protection
Efficiency up to 81%
Isolation voltage: 3K VDC
Operating temperature range: -40℃ to +105℃
Miniature SMD package
Low ripple & noise
Internal surface mounted design
International standard pin-out
Patent Protection RoHS
F_XT-1WR2 series is specially designed for applications where an isolated voltage is required in a distributed power supply system. It is suitable
for
1.Where the voltage of the input power supply is stable (voltage variation: ±10%Vin);
2.Where isolation is necessary between input and output (isolation voltage ≤ 3000VDC);
3.Where do not has high requirement of line regulation and load regulation;
Such as: pure digital circuits, low frequency analog circuits, relay-driven circuits and data switching circuits.
Selection Guide
Input Voltage (VDC)
Part No.
Output
Efficiency (%,Min./Typ.)
Max. Capacitive Load
@ Full Load
(µF)
Nominal
Output Voltage
(Range)
(VDC)
Output Current
(mA)(Max./Min.)
3.3
(2.97-3.63)
3.3
303/30
68/72
5
200/20
70/74
F0503XT-1WR2
3.3
303/30
70/74
F0505XT-1WR2
5
200/20
76/80
F0506XT-1WR2
6
167/17
76/80
F0303XT-1WR2
F0305XT-1WR2
F0509XT-1WR2
5
(4.5-5.5)
9
111/12
76/80
12
84/9
76/80
F0515XT-1WR2
15
67/7
76/80
F0524XT-1WR2
24
42/4
76/80
F1203XT-1WR2
3.3
303/30
70/74
F1205XT-1WR2
5
200/20
76/80
F0512XT-1WR2
F1209XT-1WR2
12
(10.8-13.2)
9
111/12
76/80
12
84/9
77/81
15
67/7
77/81
15
67/7
77/81
F2405XT-1WR2
5
200/20
76/80
F2409XT-1WR2
9
111/12
76/80
15
67/7
77/81
24
42/4
77/81
F1212XT-1WR2
F1215XT-1WR2
F1515XT-1WR2
F2415XT-1WR2
15
(13.5-16.5)
24
(21.6-26.4)
F2424XT-1WR2
220
Input Specifications
Item
Input Current
(full load / no-load)
Operating Conditions
Min.
Typ.
Max.
3.3V input
--
404/25
--
5V input
--
250/20
--
12V input
--
104/15
--
15V input
--
82/10
--
24V input
--
52/7
--
2014.05.22-A/3
Unit
mA
Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
F_XT-1WR2 series
Surge Voltage (1sec. max.)
3.3V input
-0.7
--
5
5V input
-0.7
--
9
12V input
-0.7
--
18
15V input
-0.7
--
21
24V input
-0.7
--
30
--
15
--
Reflected Ripple Current
Input Filter
VDC
mA
Capacitor filter
Output Specifications
Item
Operating Conditions
Min.
Output Voltage Accuracy
Input voltage
change: ±1%
Line Regulation
Load Regulation
Typ.
Max.
Unit
See tolerance envelope graph (Fig. 1)
10%-100% load
Ripple & Noise*
20MHz bandwidth
Temperature Drift Coefficient
100% load
3.3VDC output
--
--
±1.5
Others output
--
--
±1.2
3.3VDC output
--
18
--
5VDC output
--
12
--
6VDC output
--
10
--
--
9VDC output
--
8
--
12VDC output
--
7
--
15VDC output
--
6
--
24VDC output
--
5
--
Output Voltage ≤12V
--
30
--
Output Voltage:15V, 24V
--
60
--
--
±0.03
--
Output Short Circuit Protection
%
mVp-p
%/℃
Continuous, self-recovery
Note: * Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
General Specifications
Item
Operating Conditions
Min.
Isolation Voltage
Input-output, with the test time of 1 minute and the leak
current lower than 1mA
3000
--
--
VDC
Isolation Resistance
Input-output, isolation voltage 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-output, 100KHz/0.1V
--
20
--
pF
Operating Temperature
Derating if the temperature ≥100℃, (see Fig. 2)
-40
--
105
-55
--
125
--
25
--
--
--
300
Storage Temperature
Casing Temperature Rise
Ta=25℃
Pin Welding Resistance Temperature
Welding spot is 1.5mm away from the casing, 10 seconds
Typ.
Max.
Unit
℃
Peak temp.≤245℃, maximum duration
time≤60s at 217℃.
For actual application, please refer to
IPC/JEDEC J-STD-020D.1.
Reflow Soldering Temperature
Storage Humidity
Non-condensing
Switching Frequency
100% load, nominal input voltage
MTBF
MIL-HDFK-217F@25℃
--
--
--
100
3500
--
95
300
--
%
KHz
K hours
Physical Specifications
Casing Material
Black flame-retardant heat-proof epoxy resin (UL94-V0)
Package Dimensions
12.70*11.20*7.25 mm
Weight
1.5g(Typ.)
Cooling Method
Free air convection
EMC Specifications
EMI
EMS
Conducted disturbance
CISPR22/EN55022
CLASS B (see Fig. 4 for recommended circuit)
Radiated emission
CISPR22/EN55022
CLASS B (see Fig. 4 for recommended circuit)
Electrostatic discharge
IEC/EN61000-4-2
Contact
±6KV
perf. Criteria B
2014.05.22-A/3
Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
F_XT-1WR2 series
Output Power Per centage(%)
Product Characteristic Curve
Tolerance Enve lope Gra ph
+10%
Ty p ic a
+5%
Rated
Output Voltage
l L o ad
C u rv e
+2.5%
Output Voltage
Accuracy(%)
-2.5%
-7.5%
50
70
100
Output Current Percentage(%)
Te mpe ratu re D e rati ng Graph
120
100
80
60
40
Safe Operati ng Area
20
0
-40
(Nominal Input Voltage)
40
80 100 105
0
Am bi ent Te mperature(℃ )
Fig. 1
Fig. 2
Efficiency Vs Input Voltage(Full Load)
100
95
90
90
80
85
F0505XT-1WR2
80
75
70
65
60
Efficiency(%)
Efficiency(%)
Efficiency Vs Output Load(Vin=5V)
100
F0505XT-1WR2
70
60
50
40
30
20
55
10
0
5.5
5.4
5.3
5.2
5.1
5.0
4.9
4.8
4.7
4.6
4.5
50
10
Input Voltage(V)
F2415XT-1WR2
70
65
60
50
60
70
80
90
100
100
90
80
70
60
50
40
30
20
10
0
F2415XT-1WR2
10
26.4
25.9
25.4
25.0
24.5
24.0
23.5
23.1
22.6
22.1
55
50
21.6
40
Efficiency(%)
Efficiency(%)
95
80
75
30
Output Current Percentage(%)
Efficiency Vs Output Load(Vin=24V)
Efficiency Vs Input Voltage (Full Load)
100
90
85
20
20
30
40
50
60
70
80
90
100
Output Current Percentage(%)
Input Voltage(V)
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a filter capacitor can be connected to the input and output terminals, see Fig.3.
Moreover, choosing suitable filter capacitor is very important , start-up problems may be caused by too large capacitance. To ensured the
modules running well, the recommended capacitive load values as shown in Table 1.
Recommended capacitive load value table (Table 1)
Vin(VDC)
Cin(µF)
Vo (VDC)
Cout(µF)
+Vo
Vin
C in
DC
DC
GN D
C out
0V
Fig.3
3.3
5
12
15
24
--
4.7
4.7
2.2
2.2
1
--
3.3
5/6
9
12
15
24
10
10
4.7
2.2
1
0.47
It is not recommended to connect any external capacitor when
output power is less than 0.5W.
2014.05.22-A/3
Page 3 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
F_XT-1WR2 series
2. EMC typical recommended circuit
LDM
Vin
Vin
C1
GND
DC/DC
GND
Input voltage (VDC)
C1
+Vo
LOAD
C2
0V
EMI
C2
LDM
3.3/5/12/15/24
4.7µF /50V
Refer to the Cout in Fig.3
6.8µH
Fig. 4
3. Output load requirements
To ensure the module work efficiently and reliably, during the operation, the min. output load should be no less than 10% of the full load. If the
actual output power is low, please connect a resister to the output terminal in parallel, with a recommenced resistance which is 10% of the
rated power, and derating is required during operation.
4. For more information please find the application notes on www.mornsun-power.com
Dimensions and Recommended Layout
Notes:
1.
Packing Information please refer to 'Product Packing Information'. Packing bag number: 58210024;
2.
If the product is operated under the min. required load, the product performance cannot be guaranteed to comply with all
performance indexes in this datasheet;
3.
The max. capacitive load should be tested within the input voltage range and under full load conditions;
4.
Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25°C, humidity<75% when inputting
nominal voltage and outputting rated load;
5.
All index testing methods in this datasheet are based on our Company’s corporate standards;
6.
The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;
7.
We can provide product customization service;
8.
Specifications of this product are subject to changes without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2014.05.22-A/3
Page 4 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages