MASWSS0200 GaAs SP3T 2.7 V CDMA-GPS Switch DC - 2.5 GHz 100 pF GND Pin 12 ANT Balanced (symmetrical) RF Ports Low Cross Modulation Low Insertion Loss: 0.55 dB at 1 GHz High Isolation: 21 dB at 2 GHz 0.5 micron GaAs PHEMT Process Lead-Free 3 mm 12-Lead PQFN Package 100% Matte Tin Plating over Copper Halogen-Free ―Green‖ Mold Compound 260°C Reflow Compatible RoHS* Compliant Version of MASWSS0060 Pin 1 V1 V3 RF1 RF3 100 pF Description 100 pF The design is symmetric and has been fully optimized for excellent cross modulation performance in all three paths while still maintaining excellent insertion loss and isolation. Note that since the design is symmetric, the user can assign CDMA cellular, CDMA PCS and GPS to ports RF1, RF2 or RF3 at his or her discretion. 100 pF GND GND V2 GND M/A-COM’s MASWSS0200 is an industry leading GaAs PHEMT MMIC single pole three throw (SP3T) CDMA-GPS switch in a lead-free 3 mm 12-lead PQFN package. The MASWSS0200 is uniquely configured to enable switching from a common antenna port to CDMA cellular, CDMA PCS, or GPS ports. RF2 Functional Schematic GND Features Rev. V1 Pin Configuration Pin No. Function Description 1 V1 Control 1 2 RF1 RF Port 1 3 GND Ground 4 GND Ground 5 RF2 RF Port 2 6 V2 Control 2 7 GND RF Ground 8 RF3 RF Port 3 9 V3 Control 3 10 GND RF Ground The MASWSS0200 is fabricated using a 0.5 micron gate length GaAs PHEMT process. The process features full passivation for performance and reliability. Ordering Information Package 11 ANT Antenna Port MASWSS0200TR-3000 3000 piece reel 12 GND RF Ground MASWSS0200SMB Sample on Evaluation Board 13 GND (paddle) RF Ground Part Number Note: Reference Application Note M513 for reel size information. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 1 1 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASWSS0200 GaAs SP3T 2.7 V CDMA-GPS Switch DC - 2.5 GHz Rev. V1 Electrical Specifications: TA = 25°C, Z0 = 50 Ω 1 Parameter Test Conditions Units Min. Typ. Max. 1.0 GHz 1.5 GHz 2.0 GHz dB dB dB — — — 0.55 0.60 0.70 0.70 0.75 0.90 Isolation DC - 1.0 GHz 1.0 - 2.0 GHz 2.0 - 2.5 GHz dB dB dB 23 18 16 27 21 20 — — — Return Loss (All RF ports) DC - 2.5 GHz dB — 20 — IP3 Two Tone, +22 dBm/tone, 1 MHz Spacing, 820 MHz Two Tone, +22 dBm/tone, 1 MHz Spacing, 1880 MHz dBm dBm — — 62 61 — — Cross Modulation For Cell Band: Two-tone signal input: Tx1 = +22 dBm @ 820 MHz, Tx2 = +22 dBm @ 821 MHz, RX interfere = -23 dBm @ 869 MHz dBm — -101 — For PCS Band: Two-tone signal input: Tx1 = +18 dBm @ 1880 MHz, Tx2 = +18 dBm @ 1881 MHz, RX interfere = -23 dBm @ 1960 MHz dBm — -102 — Insertion Loss (All Paths) 2 P.1dB Vc = 0 V / 2.7 V, 1 GHz dBm — 36 — Trise, Tfall 10% to 90% RF, 90% to 10% RF, 900 MHz µS — 0.06 — Ton, Toff 50% control to 90% RF, and 50% control to 10% RF, 900 MHz µS — 0.09 — Transients In Band mV — 70 — Control Current Vc = 0 V / 2.7 V µA — — 30 1. External DC blocking capacitors are required on all RF ports. 2. Insertion Loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 500 MHz, 100 pF for 0.5 - 2.5 GHz. Absolute Maximum Ratings 3,4 Truth Table 5,6 Parameter Absolute Maximum Input Power (0.5 - 2.5 GHz, 2.7 V Control) +36 dBm Control Voltage ±8.5 volts Operating Temperature Storage Temperature ° V2 V3 1 0 0 On Off Off 0 1 0 Off On Off 0 0 1 Off Off On ° -40 C to +85 C ° ° -65 C to +150 C 3. Exceeding any one or combination of these limits may cause permanent damage to this device. 4. M/A-COM does not recommend sustained operation near these survivability limits. 2 2 V1 5. 6. ANT-RF1 ANT-RF2 ANT-RF3 Differential voltage, V (state 1) -V (state 0) must be 2.6 V minimum and must not exceed 8.5 V. 0 = -5 V to 2.4 V, 1 = -2.4 V to 5 V. M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASWSS0200 GaAs SP3T 2.7 V CDMA-GPS Switch DC - 2.5 GHz Rev. V1 Typical Performance Curves @ +25°C Isolation VSWR 1.5 35 RF1-RF2 RF2-RF1 RF3-RF2 1.4 30 1.3 25 1.2 20 1.1 1.0 0.5 1.0 1.5 2.0 2.5 3.0 15 0.5 Frequency (GHz) 2.5 3.0 Qualified to M/A-COM specification REL-201, Process Flow –2. RF1 RF2 RF3 0.6 Handling Procedures 0.4 Please observe the following precautions to avoid damage: 0.2 Static Sensitivity 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Frequency (GHz) Lead-Free 3 mm 12-Lead PQFN† † 2.0 Qualification 1.0 3 3 1.5 Frequency (GHz) Insertion Loss 0.8 1.0 Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. Reference Application Note M538 for lead-free solder reflow recommendations. M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASWSS0200 GaAs SP3T 2.7 V CDMA-GPS Switch DC - 2.5 GHz Rev. V1 M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. 4 4 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support