XP Power CPB600PS36 Ac-dc chassis mount Datasheet

AC-DC Chassis Mount
400-650 Watts
THE XPERTS IN POWER
CPB600 Series
•
Universal PFC Input
•
Low Profile (61mm)
•
Wide Output Voltage Adjustment
•
Remote ON/OFF
•
Power Good Signal
•
Remote Sense
•
Peak Current Available
Specification
Input
Remote ON/OFF
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage
Current
•
•
•
•
•
•
95-264 VAC (120-370 VDC)
47-63 Hz
8.2 A max at 115 VAC
40 A max at 230 VAC
0.98/0.95 at 115/230 VAC
0.75 mA max at 230 VAC 60 Hz
•
•
See Table
See Table
•
•
•
•
•
•
•
•
No minimum load required
400 ms typical at 230 VAC, 100% load
20 ms typical at 100% load
±0.4% max
±0.5% max
±1.0% max 0-100% load
± 1% max pk-pk 20 MHz bandwidth
110-130% of Vnom
Recycle input to reset
Operates at 105% of rated current
(101% of pk rating), <5 s auto recovery
>5 s recycle input to reset
±1.25% max -20 °C to +50 °C
Output
Output Voltage
Output Voltage
Adjustment
Minimum Load
Start-Up Time
Hold-up Time
Drift
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage
Protection
Overload Protection
•
Temperature
Coefficient
Overtemperature
Protection
•
Remote Sense
•
•
Operates in the event of fan failure
or if the operating temperature/
derating criteria is exceeded
Compensates for 0.3 V drop max
If not required sense terminals
must be connected locally
ie: +S to +M and -S to -M on CN1
•
12 V 3 mA applied between RCG &
RC2 will inhibit the output of the unit
& the fan
•
•
See Table
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency •
130kHz PFC, 330 kHz PWM
General
Efficiency
Isolation
Environmental
Operating
Temperature
Storage
Temperature
Relative Humidity
Shock
Vibration
•
•
-20 °C to +70 °C, derate linearly above
+50 °C to 50% at +70°C
-20 °C to +75 °C
•
•
•
20-90% non condensing
20 G 11 ms, once each x, y and z axis
2 G 10-55Hz for 3 min periods for
60 min along each x, y and z axis
Emissions
•
ESD
Susceptibility
Radiated
Susceptibility
EFT/Burst
Surge
•
EN55022 Level B conducted
EN55022 Level A radiated
EN61000-4-2 Level 2 contact,
Level 3 air
EN61000-4-3 Level 3
•
•
Safety Approvals
•
EMC & Safety
•
EN61000-4-4 Level 3
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL60950, C-UL (CSA 60950) EN60950
•
•
www.xpplc.com
[email protected]
OUTPUT VOLTAGE & CURRENT RATINGS
Output
Voltage
3.3 V (2.64-3.96)
5.0 V (3.96-6.00)
7.5 V (5.25-8.25)
12.0 V (8.25-13.2)
15.0 V (10.50-16.5)
24.0 V (16.5-26.4)
36.0 V (25.2-39.6)
48.0 V (38.4-56.0)
Current
Max
120 A
120 A
80 A
53 A
43 A
27 A
18 A
13 A
Peak
31 A(1)
-
Regulation
Line
Load
20 mV
40 mV
20 mV
40 mV
36 mV
60 mV
48 mV
100 mV
60 mV
120 mV
96 mV
150 mV
144 mV
150 mV
192 mV
300 mV
CPB
Ripple
Noise(2)
120 mV
120 mV
150 mV
150 mV
150 mV
150 mV
200 mV
200 mV
Efficiency
Model
72%
77%
79%
82%
82%
84%
84%
83%
CPB600PS3V3
CPB600PS05
CPB600PS7V5
CPB600PS12
CPB600PS15
CPB600PS24
CPB600PS36
CPB600PS48
(3)
Notes
1. Peak current duration 100 ms max with a duty cycle ≤35% 170-264 VAC only.
2. Measured over a 20 MHz bandwidth and from 0 °C to +50 °C.
3. Measured at nominal 230 VAC input and 100% load.
•
Mechanical Details
Weight 3.4kg
Pin
1
2
3
4
5
6
7
8
9
10
CN1/CN2 PIN CONNECTIONS
Function
+M
+ Output Voltage Monitoring
+S
+ Remote Sensing
-M
- Output Voltage Monitoring
-S
- Remote Sensing
VB
Voltage Balance
CB
Current Balance
TRM Adjustment of Output Voltage
-S
- Remote Sensing
RC2 Remote ON/OFF
RCG Remote ON/OFF Ground
Pin
1
2
3
4
5
6
7
8
CN3 PIN CONNECTIONS
Function
-S
- Remote Sensing
-S
- Remote Sensing
AUX
Auxiliary Output (12 V/0.1A)
RC1
Remote ON/OFF
AUXG AUX Ground
N.C.
No Connection
PG
Power Good Signal
PGG
Power Good Ground
Output Voltage Adjustment
60-110% of the rated output voltage is achieved by:
1. Using on-board potentiometer.
2. Applying a voltage externally between TRM & -S
on CN1 or CN2.
3. Connecting a resistor externally between TRM & -S
on CN1 or CN2.
The external voltage level is calculated below &
should not be less than -0.7 V or more than 3.0 V.
External Trim Voltage =
Required Vout x 2.5
Vnom
Mating Connector & Terminal for CN1, CN2 & CN3
Connector
CN1
S10B-PHDSS
CN2
CN3 S8B-PHDSS
Mating
Connector
PHDR-10VS
PHDR-8VS
Terminal
Mfr
Reel
SPHD-002T-P0.5
Loose
BPHD-001T-P0.5
BPHD-002T-P0.5
www.xpplc.com
J.S.T