UTC L8221G-SH2-R Integrated regulated supply for lnb Datasheet

UNISONIC TECHNOLOGIES CO., LTD
L8221
Preliminary
LINEAR INTEGRATED CIRCUIT
SINGLE LNB–BIAS, CONTROL
AND POWER MANAGEMENT
SOLUTION

DESCRIPTION
The UTC L8221 is a single chip power management and control
solution for LNB’s. The highly integrated solution provides all the
required FET and mixer bias, control detection and decoding, local
oscillator switching and a stable power supply for the IF amplifier
and additional support functions. Being at the heart of the LNB
monitoring the control, power management and environmental
conditions the UTC L8221 is able to provide reliable solution
eliminating effects such as false switching and over loading.

HSOP-8
FEATURES
* Single chip LNB bias, control and power management
* 22kHz tone detector with signal rejection for band switching
* Zero Gate FET switching
* Integrated regulated supply for LNB
* Voltage detection for polarization switching
* Programmable mixer and FET bias
* Single pin for supply and control
* No external filtering required
* Temperature compensated protected FET bias

ORDERING INFORMATION
Ordering Number
L8221G-SH2-R

Package
HSOP-8
Packing
Tape Reel
MARKING
www.unisonic.com.tw
Copyright © 2016 Unisonic Technologies Co., Ltd
1 of 5
QW-R123-020.a
L8221
Preliminary

PIN CONFIGURATION

PIN DESCRIPTION
PIN NO.
1
2
3
4
5
6
7
8
9

PIN NAME
G1
D1
D2
G2
VOUT
HB
VIN
CSUB
GND
LINEAR INTEGRATED CIRCUIT
DESCRIPTION
To G of fet 1
To D of fet 1
To D of fet 2
To G of fet 2
5V Output Terminal
To HB osc.
Power Supply (Include both voltage and tone signal)
Connect an external cap to -2.5V
Gnd (connect heat sink to ground)
BLOCK DIAGRAM
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 5
QW-R123-020.a
L8221

Preliminary
LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATING
PARAMETER
SYMBOL
RATINGS
UNIT
Supply Voltage
VIN
-0.6 ~ 25
V
Supply Current
IIN
120
mA
Power Dissipation
PD
1000
mW
Operating Temperature Range
TOPR
-40 ~ +85
°C
Storage Temperature Range
TSTG
-40 ~ +125
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

ELECTRICAL CHARACTERISTICS (TA=25°C, VIN=13V, unless otherwise specified)
PARAMETER
Supply Voltage Operating Range
Supply Current
No Load Supply Current
Max Bias Load Current (Note1)
Max Osc Load Current (Note 1)
Max Lout Load Current (Note 1)
VOUT
VOUT
SYMBOL
VIN
TEST CONDITIONS
TYP
MAX
22
UNIT
V
2
3
20
20
80
mA
mA
mA
mA
4.75
-3.0
5
-2.5
14.1
14.7
5.25
-2.0
-2.0
15.4
1
V
V
V
V
ms
IIN (no load) I D1=ID2=0mA
I D1 or ID2
HB
VOUT
Substrate Voltage
VSUB
VPOL Threshold
Pol Switching Speed
Output Noise
Drain Voltage
Gate Voltage
Tone Detector
Tdetect Threshold
Rejection Freq (Note 2)
Lo Output Stage
HB VOUT Low
HB VOUT High
Gate Characteristics
G1 Output
Voltage Off
Voltage Low
Voltage High
G2 Output
Voltage Off
Voltage Low
Voltage High
VPOL
TPOL
VIN=10.5V ~ 21V, IOUT=30mA
(Internally generated), ISUB=0mA
ISUB=-20uA
Applied Via VIN
VIN (Low)=13V, VIN (High)=18V
CGATE-GND=4.7nF, CDRAIN-GND=10nF
ICGATE-GND=4.7nF, CDRAIN-GND=10nF
0.02 Vpk-pk
0.005 Vpk-pk
VTONE
FTONE
Test Circuit
Test Circuit, V (AC) in=1Vp/p sq.w.
100
1.0
170
7.5
300
mV
kHz
VHBL
VHBH
II=0, Test Circuit , Tone disabled
II=20mA, Test Circuit, Tone enabled
-0.01
4.5
0
0.01
VOUT
V
V
VG1O
VG1L
VG1H
I D1=0, VIN=14V, IG1=0
I D1<=12mA, VIN=15.5V, IG1=-10uA
I D1=>8mA, VIN=15.5V, IG1=0
-0.05
-3.0
0.4
0
-2.5
0.65
0.05
-2.0
1.0
V
V
V
VG2O
VG2L
VG2H
ID2=0, VIN=15.5V, IG2=0
I D1<=12mA, VIN=14V, IG2=-10uA
IG2=>8mA, VIN=14V, IG2=0
-0.05
-3.0
0.4
0
-2.5
0.65
0.05
-2.0
1.0
V
V
V
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
8
3 of 5
QW-R123-020.a
L8221

Preliminary
LINEAR INTEGRATED CIRCUIT
ELECTRICAL CHARACTERISTICS (Cont.)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN TYP
Drain Characteristics
D1 Output
Voltage High
VD1
I D1=10mA, VIN=15.5V
1.8
2.0
Leakage Current
ILEAK1
V D1=0.5, VIN=14V
D2 Output
Voltage High
VD2
ID2=10mA, VIN=14V
1.8
2.0
Leakage Current
ILEAK2
VD2=0.5, VIN=15.5V
D1, 2
Delta VD vs. VCC
∆VDV
VCC=9 ~ 21V
0.5
Delta VD vs. TJ
∆VDT
TJ=-40 ~ +85°C
50
FET Current Range
I D1, I D2
0
Drain Current
ID
ID1, ID2, RCALA=22K
8
10
Delta Id vs. VCC
∆IDV
VCC=9 ~ 21V
0.5
Delta Id vs. TJ
∆IDT
TJ=-40 ~ +85°C
0.05
Notes: 1. The total combined load currents should not exceed the stated maximum load current.
2. The UTC L8221 series will also reject DiSEqC and other common switching tone bursts.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MAX
UNIT
2.2
10
V
uA
2.2
10
V
uA
15
12
%/V
ppm
mA
mA
%/V
%/°C
4 of 5
QW-R123-020.a
L8221

Preliminary
LINEAR INTEGRATED CIRCUIT
TEST CIRCUIT
The above is partial application circuit for the UTC L8221 series showing all external components required for
appropriate biasing. The bias circuits are unconditionally stable over the full temperature range with the associated
FETs and gate and drain capacitors in circuit. Capacitors C1 and C2 ensure that residual power supply and
substrate generator noise is not allowed to affect other external circuits which may be sensitive to RF interference.
They also serve to suppress any potential RF feed through between stages via the UTC L8221 device. These
capacitors are required for all stages used. Values of 10nF and 4.7nF respectively are recommended however this is
design dependent and any value between 1nF and 100nF could be used.
The capacitor CSUB is an integral part of the UTC L8221’s negative supply generator. The negative bias voltage
is generated on-chip using an internal oscillator. The required value of capacitor CSUB is 47nF. This generator
produces a low current supply of approximately -3 volts. Although this generator is intended purely to bias the
external FETs, it can be used to power other external low current circuits via the CSUB pin.
The UTC L8221 devices have been designed to protect the external FETs form adverse operating conditions.
With a JFET connected to any bias circuit, the gate output voltage of the bias circuit can not exceed the range
-3.0V~1V under any conditions, including power up and power down transients. Should the negative bias generator
be shorted or overloaded so that the drain current of the external FETs can no longer be controlled, the drain supply
to FETs is shut down to avoid damage to the FETs by excessive drain current. The UTC L8221 incorporates over
and under voltage protection so is the receiver or installation develops a fault the LNB will shut down and restart
once operating conditions are back to normal.
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
5 of 5
QW-R123-020.a
Similar pages