Analog Input/Output Combination Modules for Compact FieldPoint and FieldPoint NI [c]FP-AIO-600 ◾◾ 4 voltage or current inputs ◾◾ ±30 V ◾◾ 0 to 20, 4 to 20 mA ◾◾ 4 current outputs ◾◾ 0 to 10 V ◾◾ 0 to 20, 4 to 20 mA ◾◾ 12-bit resolution ◾◾ Input and output ranges software configurable per channel ◾◾ 2,300 Vrms bank isolation for transient overvoltage protection ◾◾ Hot swappable with autoconfiguration ◾◾ -40 to 70 °C operating range Module Input Channels [c}FP-AIO-600 4 Input Ranges (Software Configurable per Channel) Output Channels Output Ranges (Software Configurable per Channel) Resolution All Channel Update Rate 4 Current: 0 to 20 mA, 4 to 20 mA 12 bits 1.7 kHz Current: 0 to 20 mA, 4 to 20 mA Voltage: ±5 V, ±15 V, ±30 V, 0 to 5 V, 0 to 15 V, 0 to 30 V Overview [c]FP-AIO-600 The NI [c]FP-AIO-600 is a versatile combination analog input and analog output The [c]FP-AIO-600 includes four 0 to 30 V or 0 to 20/4 to 20 mA analog inputs module for Compact FieldPoint and FieldPoint that you can use to measure and four 0 to 20/4 to 20 mA analog outputs. The analog inputs and outputs use a voltages and 0 to 20 or 4 to 20 mA current loops from industrial sensors and 12-bit DAC. Each output channel includes a monitoring circuit and LED indicator transmitters and to control valves, gauges, and other industrial actuators. The for open current loop detection. The [c]FP-AIO-600 requires an external power [c]FP-AIO-600 is ideal for low-channel-count systems or for PID control with supply, providing 5 to 30 VDC. high-speed I/O. The module has overranging and onboard diagnostics to ensure trouble-free installation and maintenance. The [c]FP-AIO-600 measures and linearizes signals onboard to return scaled values to your control or monitoring software, accept engineering units from your control or monitoring software, Isolation The [c]FP-AIO-600 features optical bank isolation with 2,300 Vrms of breakdown isolation. These Compact FieldPoint and FieldPoint modules do not have and automatically scale and linearize output signals. The [c]FP-AIO-600 module channel-to-channel isolation. comes with a NIST-traceable calibration certificate, ensuring accurate and Field I/O Connections reliable analog measurement and control. Smart I/O Module You can connect the [c]FP-AIO-600 directly to industrial actuators or units under test and achieve high-accuracy measurement and control. The module calibrates, scales engineering units to sensor signals, and performs self-diagnostics to look for problems with the module or with the wiring, such as open current loops. With the [c]FP-AIO-600 module, your software application reads and writes engineering values from the module, eliminating the error-prone step of converting voltage or current to binary values. The module has an update rate of 1.7 kHz. Overall data throughput depends on the software loop speeds and the network speeds. Compact FieldPoint and FieldPoint modules include a built-in power distribution bus that provides multiple power connections on the module. A field-wired power supply connected to the voltage (V) and common (C) terminals is internally connected to a power distribution bus that provides additional breakout terminals for voltage supply (Vsup) and common (COM). These terminals offer a convenient way to distribute power to field devices that require external power. The [c]FP-AIO-600 has: ◾◾ 4 voltage input terminals (Vin) ◾◾ 4 current input terminals (Iin) ◾◾ 4 current output terminals (Iout) ◾◾ 12 common terminals (COM) ◾◾ 8 power connections for field devices or current loops (Vsup) Analog Input/Output Combination Modules for Compact FieldPoint and FieldPoint Ordering Information Compact FieldPoint NI cFP-AIO-600..............................................................................777318-600 Recommended Compact FieldPoint System Products NI cFP-2220.................................................................................777317-2220 NI cFP-BP-4.....................................................................................778617-04 NI cFP-CB-1.....................................................................................778618-01 PS-15 power supply........................................................................781093-01 NI Developer Suite Professional Control Edition............................777906-03 FieldPoint FP-AIO-600....................................................................................777518-600 Recommended FieldPoint System Products NI FP-1601.......................................................................................777792-01 NI FP-TB-1.......................................................................................777519-01 PS-4 power supply..........................................................................778586-90 NI Developer Suite Standard Control Edition.................................777905-03 BUY NOW For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/fieldpoint. BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.) 2 Analog Input/Output Combination Modules for Compact FieldPoint and FieldPoint Specifications cFP-AIO-600 Offset Errors Typical for -40 to 70 °C unless otherwise noted. Voltage Input Range Offset Errors at 15 to 35 °C Offset Errors at -40 to 70 °C 0-20 mA 9 μA typ, 20 μA max 9 μA typ, 20 μA max 4-20 mA 9 μA typ, 20 μA max 9 μA typ, 20 μA max ±20 mA 16 μA typ, 38 μA max 17 μA typ, 38 μA max Input and Output Characteristics Number of input channels..................... 4 Number of output channels................... 4 ADC resolution....................................... 12 bits Type of ADC............................................ Successive approximation DAC resolution....................................... 12 bits Type of DAC............................................ R-2R Update rate (all channels)...................... 1.7 kHz (588 μs) Current Outputs ([c]FP-AIO-600) Voltage Inputs Output ranges........................................ 0-20 or 4-20 mA, programmable (0-21 or 3.5-21 mA with overranging) Output type............................................ Current source (external power supply required) External power supply........................... 10-30 VDC, 125 mA for four output channels 3V Effective resolution................................ 11.3 bits Internal voltage drop.............................. Input impedance.................................... 1.5 MW Resistive load.........................................Up to 1 kW with 24 VDC power supply Input signal bandwidth.......................... 350 Hz Protection............................................... Short-circuit and open-circuit Default power-up state.......................... 0 mA Isolation Voltage cFP-AIO-600 Gain Errors Voltage Input Range Gain Errors at 15 to 35 °C Gain Errors at -40 to 70 °C Current Output Range (with Overrange) Accuracy at 15 to 35 °C (% of Output Value; % of Full Scale) Accuracy at -40 to 70 °C (% of Output Value; % of Full Scale) 0-5 V 0.03% typ, 0.04% max 0.11% typ, 0.16% max 0-10 V 0.03% typ, 0.04% max 0.11% typ, 0.16% max 0 to 21 mA ±0.03%; ±0.13% ±0.14%; ±0.2% 0-15 V 0.03% typ, 0.04% max 0.11% typ, 0.16% max 3.5 to 21 mA ±0.03%; ±0.16% ±0.14%; ±0.23% 0-30 V 0.03% typ, 0.04% max 0.11% typ, 0.16% max ±5 V 0.03% typ, 0.04% max 0.13% typ, 0.19% max Isolation Voltage ±10 V 0.03% typ, 0.04% max 0.13% typ, 0.19% max Maximum isolation voltage................... 250 Vrms, Installation Category II ±15 V 0.03% typ, 0.04% max 0.13% typ, 0.19% max Channel-to-channel isolation................. No isolation between channels ±30 V 0.03% typ, 0.04% max 0.13% typ, 0.19% max Transient overvoltage............................. 2,300 Vrms cFP-AIO-600 Offset Errors Dynamic Characteristics Voltage Input Range Offset Errors at 15 to 35 °C Offset Errors at -40 to 70 °C Maximum update rate........................... 1,700 updates/s 0-5 V 4 mV typ, 9 mV max 6 mV typ, 15 mV max Slew rate................................................ 0.4 mA/μs 0-10 V 6 mV typ, 14 mV max 8 mV typ, 20 mV max 0-15 V 8 mV typ, 18 mV max 10 mV typ, 24 mV max Physical Characteristics 0-30 V 13 mV typ, 32 mV max 15 mV typ, 37 mV max LED indicators ±5 V 6 mV typ, 14 mV max 8 mV typ, 20 mV max POWER (green).................................. Power on and self-test passed ±10 V 10 mV typ, 23 mV max 12 mV typ, 29 mV max READY (green)................................... Module configured and ready ±15 V 14 mV typ, 32 mV max 16 mV typ, 38 mV max Fault status (red)................................ Open circuit ±30 V 25 mV typ, 59 mV max 28 mV typ, 64 mV max Dimensions (FP only, including terminal base)...... Current Inputs Effective resolution................................ 11.3 bits Input impedance.................................... 105 W Overcurrent protection........................... ±100 mA Overvoltage protection.......................... ±10 V Input signal bandwidth.......................... 400 Hz Gain errors 15 to 35 ºC......................................... 0.08% typ, 0.18% max -40 to 70 ºC........................................ 0.25% typ, 0.66% max 10.7 by 10.9 by 9.1 cm (4.2 by 4.3 by 3.6 in.) Weight FP-AIO-600......................................... 141 g (4.9 oz) cFP-AIO-600....................................... 111 g (3.9 oz) Power Requirement Power from network module................. 350 mW BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.) 3 Analog Input/Output Combination Modules for Compact FieldPoint and FieldPoint Environment Operating temperature.......................... -40 to 70 °C Storage temperature.............................. -55 to 85 °C Relative humidity................................... 10 to 90%, noncondensing Shock and Vibration These specifications apply only to Compact FieldPoint. NI recommends Compact FieldPoint if your application is subject to shock and vibration. Operating vibration, random (IEC 60068-2-64)................................ 10 to 500 Hz, 5 grms Operating vibration, sinusoidal (IEC 60068-2-6).................................. 10 to 500 Hz, 5 g Operating shock (IEC 60068-2-27)................................ 50 g, 3 ms half sine, 18 shocks at 6 orientations; 30 g, 11 ms half sine, 18 shocks at 6 orientations Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: ◾◾ IEC 61010-1, EN 61010-1 ◾◾ UL 61010-1, CSA 61010-1 Note: For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ◾◾ EN 61326 (IEC 61326): Class A emissions; Industrial immunity ◾◾ EN 55011 (CISPR 11): Group 1, Class A emissions ◾◾ AS/NZS CISPR 11: Group 1, Class A emissions ◾◾ FCC 47 CFR Part 15B: Class A emissions ◾◾ ICES-001: Class A emissions Note: For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Note: For EMC compliance, operate this product according to the documentation. CE Compliance This product meets the essential requirements of applicable European Directives as follows: ◾◾ 2006/95/EC; Low-Voltage Directive (safety) ◾◾ 2004/108/EC; Electromagnetic Compatibility Directive (EMC) BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.) 4 NI Services and Support your needs around the globe and through PL AN MA IN NI has the services and support to meet IN TA the application life cycle – from planning and development through deployment and SERVICE NEEDS ongoing maintenance. We offer services P DE EL OP and service levels to meet customer LO Y requirements in research, design, validation, V DE and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Training and Certification Visit ni.com/ssp. NI training is the fastest, most certain route to productivity with our products. Hardware Services NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led System Assurance Programs courses in cities worldwide, or we can hold a course at your facility. We also NI system assurance programs are designed to make it even easier for you offer a professional certification program that identifies individuals who have to own an NI system. These programs include configuration and deployment high levels of skill and knowledge on using NI products. services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic Visit ni.com/training. System Assurance Program provides a simple integration test and ensures that Professional Services your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select Our NI Professional Services team is composed of NI applications and systems from available NI system driver sets and application development environments engineers and a worldwide National Instruments Alliance Partner program of to create customized, reorderable software configurations. Your system arrives more than 600 independent consultants and integrators. Services range from fully assembled and tested in one box with your software preinstalled. When start-up assistance to turnkey system you order your system with the standard program, you also receive system- integration. Visit ni.com/alliance. specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. OEM Support Finally, the standard program reduces the total cost of owning an NI system We offer design-in consulting and product integration assistance if you want to online product advisors at ni.com/advisor to find a system assurance program use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. by providing three years of warranty coverage and calibration service. Use the to meet your needs. Calibration Services NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com n 800 813 3693 National Instruments n [email protected] ©2009 National Instruments. All rights reserved. CompactRIO, FieldPoint, National Instruments, National Instruments Alliance Partner , NI, ni.com, and NI Developer Suite are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. 0644