GE G4B Glass passivated junction rectifier Datasheet

G4A THRU G4J
GLASS PASSIVATED JUNCTION RECTIFIER
Reverse Voltage - 50 to 600 Volts
Forward Current - 3.0 Amperes
*
FEATURES
♦ High temperature metallurgically bonded
construction
♦ Glass passivated cavity-free junction
♦ Hermetically sealed package
♦ 3.0 Ampere operation
at TA=75°C with no
thermal runaway
♦ Typical IR less than 0.1µA
♦ Capable of meeting environmental standards of
MIL-S-19500
♦ High temperature soldering guaranteed:
350°C/10 seconds 0.375" (9.5mm) lead length,
5 lbs. (2.3kg) tension
P
A
T
E
N
T
E
D
Case Style G4
0.180 (4.6)
0.115 (2.9)
DIA.
1.0 (25.4)
MIN.
0.300 (7.6)
MAX.
0.042 (1.07)
0.038 (0.962)
DIA.
1.0 (25.4)
MIN.
MECHANICAL DATA
Case: Solid glass body
Terminals: Solder plated axial leads, solderable per
MIL-STD-750, Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.037 ounce,1.04 grams
Dimensions in inches and (millimeters)
*Brazed-lead assembly is covered by Patent No. 3,930,306
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
G4A
G4B
Maximum repetitive peak reverse voltage
VRRM
50
100
Maximum RMS voltage
VRMS
35
70
Maximum DC blocking voltage
VDC
50
100
200
Maximum average forward rectified current, 0.375”
(9.5mm) lead length at TA=70°C
I(AV)
3.0
Amps
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method)
IFSM
100.0
Amps
Maximum instantaneous forward voltage at 3.0A
VF
1.1
Volts
Maximum full load reverse current full cycle
average, 0.375” (9.5mm) lead length at TA=70°C
IR(AV)
200.0
µA
IR
1.0
100.0
µA
Typical reverse recovery time (NOTE 1)
trr
3.0
µs
Typical junction capacitance (NOTE 2)
CJ
40.0
pF
RΘJA
RΘJL
22.0
12.0
°C/W
TJ, TSTG
-65 to +175
°C
Maximum DC reverse current
at rated DC blocking voltage
TA=25°C
TA=100°C
Typical thermal resistance (NOTE 3)
Operating junction and storage temperature range
NOTES:
(1) Reverse recovery test conditions: IF=0.5A, IR=1.0A, Irr=0.25A
(2) Measured at 1.0 MHZ and applied reverse voltage of 4.0 Volts
(3) Thermal resistance from junction to ambient and from junction to lead at 0.375” (9.5mm)
lead length with both leads mounted between heatsinks
4/98
G4D
G4G
G4J
UNITS
200
400
600
Volts
140
280
420
Volts
400
600
Volts
RATINGS AND CHARACTERISTIC CURVES G4A AND G4J
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
AVERAGE FORWARD RECTIFIED
CURRENT, AMPERES
FIG. 1 - FORWARD CURRENT DERATING CURVE
200
60 HZ
RESISTIVE OR
INDUCTIVE LOAD
3.0
2.0
1.0
0.375" (9.5mm) LEAD LENGTH
0
0
25
50
75
100
125
150
175
AMBIENT TEMPERATURE, °C
PEAK FORWARD SURGE CURRENT,
AMPERES
4.0
TJ =TJ max.
8.3ms SINGLE HALF
SINE-WAVE (JEDEC Method)
100
10
1
10
100
NUMBER OF CYCLES AT 60 HZ
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
20
30
10
TJ=150°C
PULSE WIDTH = 300µs
1% DUTY CYCLE
TJ=25°C
1
0.1
0.01
0.2
0.6
0.8
1.0
1.2
1.4
1.6
1
TJ=75°C
0.1
100
TJ=25°C
f=1.0 MHz
Vsig=50mVp-p
10
10
REVERSE VOLTAGE, VOLTS
0.01
0
20
40
60
80
PERCENT OF RATED PEAK REVERSE VOLTAGE, %
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE, pF
TJ=125°C
TJ=25°C
0.4
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
1
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,
AMPERES
10
100
100
Similar pages