Click on Series name for product info on aimtec.com Series AM2L-NZ 2 Watt | DC-DC Converter FEATURES: • • • • • MTBF>1,000,000 hours • Operating temperature: -40°C to +85°C Industry Standard Pinout • High Efficiency up to 85% Unregulated Single, Dual, Dual Separated Output Models Low Profile SMD (Surface Mount Device) 1000VDC & 6000VDC Isolation Models Single output Input Voltage(V) Output Voltage (V) AM2L-0515S-NZ *AM2L-1205S-NZ *AM2L-1212S-NZ 4.5-5.5 10.8-13.2 10.8-13.2 15 5 12 AM2L-0505SH60-NZ AM2L-1205SH60-NZ AM2L-1215SH60-NZ AM2L-2405SH60-NZ AM2L-2412SH60-NZ AM2L-2415SH60-NZ 4.5-5.5 10.8-13.2 10.8-13.2 21.6-26.4 21.6-26.4 21.6-26.4 5 5 15 5 12 15 Input Voltage (V) Output Voltage (V) Model Output Current max(mA) Isolation (VDC) Efficiency (%) 133 400 167 1000 1000 1000 84 82 85 400 400 133 400 167 133 6000 6000 6000 6000 6000 6000 77 78 81 79 82 80 Output Current max (mA) Isolation (VDC) Efficiency (%) ±200 ±111 ±83 ±67 ±200 ±111 ±83 ±67 1000 1000 1000 1000 1000 1000 1000 1000 82 83 84 82 83 84 84 85 Models Dual output Model AM2L-0505D-NZ *AM2L-0509D-NZ AM2L-0512D-NZ *AM2L-0515D-NZ *AM2L-1205D-NZ *AM2L-1209D-NZ *AM2L-1212D-NZ AM2L-1215D-NZ 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 ±5 ±9 ±12 ±15 ±5 ±9 ±12 ±15 Models Dual Separated output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) *AM2L-050505D-NZ 4.5-5.5 5/5 200/200 1000 82 *AM2L-120505D-NZ 10.8-13.2 5/5 200/200 1000 82 *AM2L-121515D-NZ 10.8-13.2 15/15 67/67 1000 85 *Not recommended for new design NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range www.aimtec.com F 051e R12.Q Nominal Typical 5 12 24 4.5-5.5 10.8-13.2 21.6-26.4 Tel: +1 514 620 2722 1 of 5 Maximum Units VDC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2L-NZ 2 Watt | DC-DC Converter Isolation Specifications Parameters Tested I/O voltage Tested V1 output/ V2 output Capacitance V input/V output Capacitance V1 output/V2 output Resistance Conditions Typical 60 sec 60 sec 500VDC 500VDC 500Vdc Rated Units 1000, 6000 VDC VDC pF pF MOhm 1000 10 10 >1000 Output Specifications Parameters Voltage accuracy Short Circuit protection Short Circuit Restart Line voltage regulation Load voltage regulation (5 Vout) Load voltage regulation (9 Vout) Load voltage regulation (12 Vout) Load voltage regulation (15 Vout) Temperature coefficient Ripple & Noise* Minimum Load Current** Conditions Typical See Tolerance Graph 1000VDC Momentary 6000VDC Continuous Maximum ±5 Units % 1 sec Auto-Recovery ±1.2 12.8 8.3 6.8 6.3 ±0.03 150 10 For a 1% change of Vin From 10% load to 100% load At 100% load 20MHz Bandwidth % % o %/ C mV p-p % of Max *Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick & POL DC-DC Converters” available on Aimtec’s website www.aimtec.com **If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the load to ensure the actual load current meets the minimum load current requirement. General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum Soldering Temperature Conditions Typical 100% load, nominal input -40 to + 85 -55 to + 125 Maximum Units 100 KHz o C o C o C 100 Free Air Convection 95 % RH Plastic(UL94-V0) 1000VDC 2.1 g 6000VDC 3.8 Single, Dual, Dual Separated 1000VDC 0.70 x 0.70 x 0.24 inches 17.78 x 17.78 x 6.00 mm Single 6000VDC 0.94 x 0.79 x 0.32 inches 23.86 x 18.50 x 8.00mm >1,000, 000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC) o 1.5mm from case for 10 seconds 260 C Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 051e R12.Q CE (for 6000VDC isolation models) EN 60601-1-1; EN 60601-1-2 Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2L-NZ 2 Watt | DC-DC Converter Pin Out Specifications 1000VDC Pin Single 1 2 5 6 7 8 9 10 12 13 14 6000VDC Dual Separated Dual -Vin + Vin NC - Vout +Vout NC NC NC NC NC NC - Vin + Vin -Vout Common +Vout NC NC -Vout NC NC NC - Vin + Vin -V1out +V1out NC NC +V2out -V2out NC NC NC NOTE: On dual output models Pin 5 and Pin 10 are connected internally together. Either Pin 5 or Pin 10, or both can be used as the -Vout NC: not connected Pin Single 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 - V in No Pin No Pin No Pin No Pin No Pin NC NC +V out -V out No Pin No Pin No Pin No Pin No Pin +V in Dimensions 1000VDC Side View 17.78 (0.70) Front View A 2.75 (0.11) 6.00 5.75 (0.24) (0.23) 0.25 (0.01) A 2.54 (0.10) 1.27 (0.05) Top View 0.25 (0.01) 17.78 (0.70) 1.00 2.00 (0.04) (0.08) 14 13 12 2.54 (0.10) 5.00º angle 10 9 8 1.30 ±0.13 (0.05 ±0.005) MAX 17.78 12.70 (0.70) (0.50) 1 www.aimtec.com F 051e R12.Q 2 3 5 6 7 Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2L-NZ 2 Watt | DC-DC Converter Dimensions 6000VDC Side View 23.86 (0.94) Front View 8.00 7.50 (0.32) (0.30) A 3.04 (0.12) 13.10 (0.52) 2.54 (0.10) 1.00 (0.04) 16 18.50 (0.73) 2.00 (0.08) Top View A 10 9 0.50 (0.01) 18.50 13.70 (0.73) (0.54) 1 7 5.00º angle 1.35 ± 0.13 (0.05 ± 0.005) MAX 8 15.24 (0.60) Tolerance Envelope Graph +10% Typical Load Line +5% +2.5% Output Voltage -2.5% 10% www.aimtec.com F 051e R12.Q -7.5% 50% Output Current(%) 100% Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2L-NZ 2 Watt | DC-DC Converter Recommended Filter Circuit L Single Output L +Vout + Vin + Vin L Dual Output L +Vout + + Cin + DC DC Cin + Cout DC DC + L - Vin - Vin Cout Common Cout - Vin -Vout L Dual Separated Output L +V1output + Vin + Cout -V1 output Cin + DC DC L +V2 output + Cout -V2 output - Vin If it is required to decrease the input/output ripple an “LC” filter network can be installed on the input and output of the converter (see above). It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC converter switching frequency to avoid mutual interference. The capacitance of the outputfilter capacitor must not exceed the values in the Table below to avoid startup problems and ensure safe and reliable operation. It’s not recommended to connect any external capacitor in the application field whenoutput loading is less than 0.5 watt. External Capacitor Tables Input Capacitor (Cin) Vin (VDC) Cin (uF) 5 12 24 4.7 2.2 1 Output Capacitor (Cout) Single Vout (VDC) 5 9 12 15 Cout (uF) Dual Vout (Vdc) Cout (uF) Dual Separated Vout (Vdc) Cout (uF) 10 4.7 2.2 1 ±5 ±9 ±12 ±15 4.7 2.2 1 0.47 5/5 9/9 12/12 15/15 4.7 2.2 1 0.47 Overload Protection The output circuit of these products has no protection against overload. It is recommended to install external overload protection in the form of a self-recovery fuse or a circuit breaker in series at the converter’s input. To achieve a high degree of output voltage regulation, over-voltage, and over-current protection it is suggested to use the AM2LV-NZ series as an alternative. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.Q Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only