Gamewell-FCI FC-5C Five zone control communicator Datasheet

FC-5C
FIVE ZONE PANEL
Conventional Fire Alarm Control
Description
The FC-5C Fire Alarm Control panel is a proven, versatile,
modular control with integral communicator and remotesite Upload/Download capability. It meets the requirements of NFPA Standard 72 for Central Station, Protected
Premises, and Remote (DACT) Supervising Station Fire
Alarm Systems. It is Listed to UL Standard 864, inherently
power limited and meets all UL transient immunity requirements.
The integral communicator includes a wide range of selectable transmission formats to communicate to virtually
all central stations. Other features of the communicator
are: A line-active indicator for each of two phone lines,
“Kiss-Off’ signal LED, dual ”low telephone voltage detect"
circuitry, programmable event codes per format and selectable/deselectable transmission of 62 events. In addition, five zones may be configured to five channels as a
slave communicator with auto-resettable channels for use
with UL Listed control panels.
Multiple security techniques allow uploading or downloading within one minute without affecting normal fire panel
functions. Key system information that can be uploaded
are: Current System Status, History, Walk Test Files and
System Programming.
An integral voltmeter allows voltage measurements for
Zone, AC line, NAC 1, NAC2, resettable power and battery.
The control is housed in a red steel enclosure with back
lighted panels displaying the status of vital functions. The
surface mounted enclosure, (trim ring optional) with its
slim appearance (3-inch depth) is designed to blend with
any environment. Space is available for two (2) B-7R batteries.
The many features of the FC-5C control provide a cost
effective approach to systems design, and allow a great
degree of flexibility in one enclosure. Many of these features include Class B, Style B, (with one Class A, Style D)
initiating circuits and two (2) Class B, Style Y or Class A,
Style Z notification appliance circuits, expandable from 1.5
to 2.5 amps each. Fully programmable via integral keypad, the notification appliance circuits may be programmed Silenceable, Non-silenceable, Auto-silence
(program 5 to 30 minutes) and Silence Inhibit (60 seconds).
FC-5C
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Inherently power-limited.
Integral digital communicator.
Selectable transmission formats.
Fire drill function.
Integral voltmeter.
Fully programmable via integral keypad.
Auto-reset supervisory operation.
Temporal pattern output per ANSI S3.41.
Single person walk test.
Alarm verification.
Real-time clock/calendar.
32-Event History with time and date stamp.
Zone disable feature via software.
Plug-in modules.
Serial annunciator output (optional).
Printer interface for on or off-line printing (optional).
Contact-by-zone module (optional).
Surface mount technology.
Periodic trouble reminder via software.
Operating temperature relative humidity.
Door back box trim ring.
An ISO 9000-2000 Company
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: 203-484-7161 - Fax: 203-484-7118
©2006
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
Gamewell-FCI. All rights reserved.
www.gamewell-fci.com
9020-0458 Rev. G page 1 of 2
Description (Continued)
Ordering Information
Also programmable are Alarm Presignal Timer, Alarm
Verification Timer and Optional Trouble Reminder.
Part Number
Description
700-01190
Supervision of vital components, plug-in modules,
functional switches and standby batteries is provided. In addition, an optional serial annunciator
driver allows remote alarm annunciation.
700-01191
FC-5C
(Five zone control communicator)
FC-5C PCB
Five Zone Module, replacement board
FC-5TR
Trim Ring
PRT-24
Printer interface module - provides
RS-232 printer output.
Includes cable, DB9F and DB25
adapter.
ADM-24
Annunciator driver module
RZA-5
Remote zone annunciator, 5 zones
(requires one (1) ADM-24)
Mounts on single gang box.
RM-5F
Five-relay module (contact-by-zone)
CAC-5F
Class “A” initiating circuit converter
module
SK-5C
Software kit (upload/download utility)
XRM-FC5
120 VAC, I 00 VA transformer, expands NAC total power from 3.0 to
5.0 amperes.
MCBL-7
DACT phone cord, 7 feet long
(2 required)
700-01215
700-01192
Specifications
Operating temperature: 32° - 120° F (0° - 49° C)
Relative humidity:
85 % (non-condensing)
Dimensions:
Door
15 7/32" H x 14 7/32" W
(38.7 x 36.1 cm)
Backbox
15" H x 14 1/2" W x 3" D
(38.1 cm x 36.8 cm x 7.6 cm)
Trim Ring
18 1/8" H x 17 5/8" W
(46.0 cm x 44.8 cm)
700-01193
700-01194
700-01195
700-01196
UL Listed Receivers compatible with FC-10C:
•
•
•
•
Ademoco 685
Silent Knight 9000
ITI-CS-4000
FBI CP220FB
•
•
•
•
Osborne Hoffman Models 1 / 2
Radionics 6000/6500
Sescoa 3000R
Sur-guard MLR-2
700-01197
700-01221
600-90000
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
www.gamewell-fci.com
9020-0458 Rev. G page 2 of 2
Similar pages