M P T- 6 5 65W Triple Output Medical Type series Features : Universal AC input / Full range Low leakage current 0.3mA Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty SPECIFICATION MODEL OUTPUT MPT-65A CH2 CH3 CH1 CH2 CH3 CH1 CH2 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 5.5A 2.5A 0.5A 5.5A 2.5A 0.5A 5.5A 2A 0.5A CURRENT RANGE 0.4 ~ 7A 0.2 ~ 3.2A 0 ~ 0.7A 0.4 ~ 7A 0.2 ~ 3.2A 0 ~ 0.7A 0.4 ~ 7A 0.2 ~ 2.6A 0 ~ 0.7A RATED POWER 60W OUTPUT POWER (max.) 72W with 18CFM min. Forced air convection 180mVp-p 100mVp-p 60mVp-p 60mVp-p 65W 160mVp-p 100mVp-p 60mVp-p CH1:4.5 ~ 5.5V 4.0% +10,-7% 5.0% 4.0% +10,-7% 5.0% 4.0% +10,-7% 5.0% LINE REGULATION 1.0% 2.0% 1.0% 1.0% 2.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 3.0% 4.0% 1.0% 3.0% 4.0% 1.0% 3.0% 4.0% 1.0% 800ms, 20ms/230VAC HOLD UP TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 440Hz EFFICIENCY(Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.6A/115VAC 800ms, 20ms/115VAC at full load 12ms/115VAC at full load 127 ~ 370VDC 74% COLD START 20A/115VAC <0.3mA / 264VAC OVERLOAD 73 ~ 95W rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMC EMISSION EMC IMMUNITY 74% 1A/230VAC LEAKAGE CURRENT OVER VOLTAGE NOTE 120mVp-p CH3 VOLTAGE TOLERANCE Note.3 PROTECTION OTHERS 63.5W RIPPLE & NOISE (max.) Note.2 60mVp-p SETUP, RISE TIME (Note 4) MPT-65C CH1 VOLTAGE ADJ. RANGE INPUT MPT-65B OUTPUT NUMBER 40A/230VAC 5.75 ~ 6.75VDC on CH1 Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +55 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3 MTBF Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2, medical level, criteria A 275.1Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING 127*76*42mm (L*W*H) 0.27Kg; 54pcs/16.8Kg/1.35CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Mounting holes M1 and M2 should be grounded for EMI purposes. 6. Heat Sink HS1,HS2 can not be shorted. File Name:MPT-65-SPEC 2011-12-15 M P T- 6 5 65W Triple Output Medical Type Mechanical Specification series Unit:mm 127 5.6 115.8 5.6 FG HS1 M1 M2 64.8 76 CN2 FS1 1 2 3 4 5 6 AC FUSE T2A/250V 1 HS2 2 CN1 FS2 AC FUSE T2A/250V SVR1 4- LED 3. 2 max. 42 8 DC Output Connector (CN2) : Molex 5273-06 or equivalent AC Input Connector (CN1) : Molex 5277-02 or equivalent Pin No. 1 2 Assignment AC/N AC/L Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Pin No. 1 2,3 4,5 6 HS1,HS2 can not be shorted Assignment +V +5V COM -V Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING FG Derating Curve +V RECTIFIERS & FILTER +5V RECTIFIERS & FILTER COM -V DETECTION CIRCUIT PWM CONTROL O.L.P. fosc : 45KHz RECTIFIERS & FILTER O.V.P. Static Characteristics 100 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:MPT-65-SPEC 2011-12-15