DIODES B370_10

 B370 - B3100
Green
3.0A HIGH VOLTAGE SCHOTTKY BARRIER RECTIFIER
Features
Mechanical Data
•
•
•
•
•
•
•
•
Guard Ring Die Construction for Transient Protection
Low Power Loss, High Efficiency
Surge Overload Rating to 100A Peak
For Use in Low Voltage, High Frequency Inverters, Free
Wheeling, and Polarity Protection Application
Lead Free Finish/RoHS Compliant (Note 1)
Green Molding Compound (No Halogen and Antimony)
(Note 2)
•
•
•
•
Case: SMC
Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
Moisture Sensitivity: Level 1 per J-STD-020
Terminals: Lead Free Plating (Matte Tin Finish). Solderable per
MIL-STD-202, Method 208
Polarity: Cathode Band or Cathode Notch
Weight: 0.21 grams (approximate)
Bottom View
Top View
Ordering Information (Note 3)
Part Number*
B3x0-13-F
Case
SMC
Packaging
3000/Tape & Reel
* x = Device type, e.g. B380-13-F (SMC package).
Notes:
1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes.
2. Product manufactured with Data Code 0924 (week 24, 2009) and newer are built with Green Molding Compound.
3. For packaging details, go to our website at http://www.diodes.com.
Marking Information
YWW
B3x0
B370 - B3100
Document number: DS30020 Rev. 13 - 2
B3x0 = Product type marking code, ex: B380 (SMC package)
= Manufacturers’ code marking
YWW = Date code marking
Y = Last digit of year (ex: 2 for 2002)
WW = Week code (01 to 53)
Note: B3100 marking code is B3100
1 of 4
www.diodes.com
September 2010
© Diodes Incorporated
B370 - B3100
Maximum Ratings @TA = 25°C unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.
Characteristic
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
Symbol
VRRM
VRWM
VR
VR(RMS)
IO
RMS Reverse Voltage
Average Rectified Output Current @ TT = 90°C
Non-Repetitive Peak Forward Surge Current 8.3ms
single half sine-wave superimposed on rated load
B370
B380
B390
B3100
Unit
70
80
90
100
V
49
56
63
70
3.0
V
A
100
A
IFSM
Thermal Characteristics
Characteristic
Typical Thermal Resistance Junction to Terminal
Operating Temperature Range
Storage Temperature Range
Electrical Characteristics
Symbol
RθJT
TJ
TSTG
Unit
°C/W
°C
°C
@TA = 25°C unless otherwise specified
Characteristic
Symbol
Forward Voltage Drop
VF
Leakage Current (Note 4)
IR
Total Capacitance
CT
Min
-
Typ
-
-
-
Max
0.79
0.69
-
-
0.5
20
100
Unit
V
mA
pF
Test Condition
IF = 3.0A, TA = 25°C
IF = 3.0A, TA = 100°C
@ Rated VR, TA = 25°C
@ Rated VR, TA = 100°C
VR = 4V, f = 1MHz
4. Short duration pulse test used to minimize self-heating effect.
1,000
10
CT, TOTAL CAPACITANCE (pF)
IF, INSTANTANEOUS FORWARD CURRENT (A)
Notes:
Value
10
-55 to +125
-55 to +150
1.0
0.1
100
TJ = 25°C
IF Pulse Width = 300µs
10
0.01
0
0.2
0.4
0.6
0.8
1.0
VF, INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 1 Typical Forward Characteristics
B370 - B3100
Document number: DS30020 Rev. 13 - 2
2 of 4
www.diodes.com
0.1
1
10
100
VR, DC REVERSE VOLTAGE (V)
Fig. 2 Total Capacitance vs. Reverse Voltage
September 2010
© Diodes Incorporated
B370 - B3100
IFSM, PEAK FORWARD SURGE CURRENT (A)
IF(AV), AVERAGE FORWARD CURRENT (A)
3.0
2.5
2.0
1.5
1.0
0.5
100
80
60
40
20
0
0
25
1
10
100
NUMBER OF CYCLES AT 60 Hz
Fig. 4 Max Non-Repetitive Peak Forward Surge Current
50
75
100
125
150
TT, TERMINAL TEMPERATURE (°C)
Fig. 3 Forward Current Derating Curve
Package Outline Dimensions
B
A
SMC
Dim
Min
Max
A
5.59
6.22
B
6.60
7.11
C
2.75
3.18
D
0.15
0.31
E
7.75
8.13
G
0.10
0.20
H
0.76
1.52
J
2.00
2.50
All Dimensions in mm
C
D
J
H
G
E
Suggested Pad Layout
Dimensions Value (in mm)
B370 - B3100
Document number: DS30020 Rev. 13 - 2
3 of 4
www.diodes.com
Z
9.3
G
4.4
X
3.3
Y
2.5
C
6.8
September 2010
© Diodes Incorporated
B370 - B3100
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
(AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes
without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the
application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or
trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated
website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel.
Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and
hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or
indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings
noted herein may also be covered by one or more United States, international or foreign trademarks.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express
written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user.
B.
A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any
use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related
information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its
representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2010, Diodes Incorporated
www.diodes.com
B370 - B3100
Document number: DS30020 Rev. 13 - 2
4 of 4
www.diodes.com
September 2010
© Diodes Incorporated