This document was generated on 06/07/2010 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: Description: 1120160020 Active BradCommunications™ SST™ CommDTM software update driver license for PROFIBUS Scanner Documents: Drawing (PDF) RoHS Certificate of Compliance (PDF) General Product Family Series Approvals Communication Speed Mounting Style Product Name Protocol Type Network Interface 112016 N/A N/A N/A SST™ Profibus* DP PLC Module EU RoHS China RoHS ELV and RoHS Compliant REACH SVHC Not Reviewed Halogen-Free Status Not Reviewed Need more information on product environmental compliance? Email [email protected] For a multiple part number RoHS Certificate of Compliance, click here Please visit the Contact Us section for any non-product compliance questions. Physical Channels Interface Network Connection Type Packaging Type Processor Temperature Range - Operating 0 Profibus* N/A Carton Freescale MCF5772 0°C to +60°C Search Parts in this Series 112016Series Electrical Current - Maximum Input EMC Supply Voltage 5.5W EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2 N/A Material Info Old Part Number SST-PB3-CLX-DTS Reference - Drawing Numbers Sales Drawing E-112016-0020 This document was generated on 06/07/2010 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION The BradCommunications™ SST Profibus communication module connects your Rockwell ControlLogix® controller to PROFIBUS DP network. 30 Oct. 09 DW200588 Features • Enhanced design! For the Rockwell ControlLogix® Controller 100% backward compatible with previous generation (SST-PFB-CLX) Up to 2 times faster Easier to change module’s configuration with PLC in RUN mode Runs without ladder code Module can “Set Slave” address Dynamically add/remove Profibus slaves from scan list • Remote Configuration and diagnostic through RSLinx ® • Profibus modules can be used in Local or Remote (through CIP networks) Racks • Certified PROFIBUS CommDTM driver for FDT Frame engineering tools • Provides user-defined data space up to 1984 Bytes Input and 1968 Bytes Output • Supports all PROFIBUS baud rates including 45.45 kbps • Manages DP-V1 Services • Simultaneous operation of PROFIBUS DP Master and Slave • Multiple SST-PB3-CLX-RLL modules can be used in one CLX rack Protocols • PROFIBUS DP-V0 Master Class 1&2 • PROFIBUS DP-V1 Master Class 1&2 • PROFIBUS DP-V0 Slave Typical Applications • Chemical or pharmaceutical • PROFIBUS® DP Master/Slave Overview The BradCommunications™ SST™ Profibus® module connects your Rockwell ControlLogix® controller to Profibus as a master or slave to scan or emulate PROFIBUS DP I/O. With the new user-defined data space of 1984 Bytes Input and 1968 Bytes Output, the BradCommunications™ SST™ Profibus module provides a cost efficient solution to connect the ControlLogix CPU with large PROFIBUS networks. Remote Link Library The Remote Link Library software provides added functionality to the BradCommunications SST Profibus module by allowing you to remotely monitor or download changes to your Profibus configuration. This is done by routing data from the BradCommunications SST Profibus DP Master Configuration software through ® Rockwell Automation ’s RSLinx software via Ethernet to the Allen-Bradley ControlLogix backplane. The Profibus Scanner can be used on a Local Rack or on a Remote Rack through CIP networks like EtherNet/IP or ControlNet CommDTM Driver for FDT Tools By purchasing SST-PB3-CLX-DTM part number, you will get the driver license to use the certified CommDTM driver conforms to FDT v1.2 specifications. It is the ™ ideal solution for connecting FDT engineering tools such as PACTware or FieldCare™ to PROFIBUS. It allows the linking with Device DTMs for the configuration and diagnostics with DP-V1 devices including Profibus PA field instruments. application running PROFIBUS PA Machine builder application with high-speed control requirements - Fieldcare Screenshot - - Pactware Screenshot - PROFIBUS® DP Scanner Diagnostic & Software Tools Network Specifications Configuration Software • Supports downloading and uploading configuration files through Serial or Ethernet port • Browse your DP network for slave devices you want to include in your DP Master configuration using the DPView component Scanner Software • • Maintains slave status, diagnostic status information on all slaves, network diagnostic counters, and DP Master diagnostic counters Maintains network and I/O module status information including: • Active Slave Station Bit table • Configured Slave Station Bit table • Network diagnostic counters • DP Master diagnostic counters • • • Protocol Cable • • • • • • • • • Connector • LAN Controller Slaves Supported I/O per Slave I/O Mapping (for ControlLogix) Data Rate Hardware Specifications ® ® Bus Interface Allen-Bradley ControlLogix 5000 Processor Freescale MCF5272 • • • Memory Diagnostic • • PROFIBUS DP-V0 Master, class 1&2 PROFIBUS DP-V1 Master, class 1&2 PROFIBUS DP-V0 Slave (up to 122 words of input data and 122 words of output data as slave) Siemens ASPC2 Maximum of 125 Maximum of 244 bytes in/out Maximum 1984 bytes input data Maximum 1968 bytes output data 250 words status All Profibus data rates up to 12 Mbps Belden 3079A ® Brad Harrison 85-0001 PVR2 conductor with shield, UL-listed DB9 female connector 8MB of local MCF5272 RAM 512 KB of onboard shared memory 512 KB of sectored flash memory for storage of program and configuration data Built-in 4 character display 3 LEDs indicate: 1. Health of the Profibus network (COMM) 2. Communication status with Profibus slaves (SYS) 3. that initialization is complete and the module is ok (OK) Built-in 4 character display Diagnostics COMM, SYS and OK LEDs provide immediate notification of network and system errors Backplane Current Consumption 850 mA @ 5V or 1.75 mA @ 24V Operating Temperature 0ºC (32ºF) up to +60ºC (140ºF) Other PROFIBUS Products Storage Temperature -40ºC (-40F) up to +85ºC (185F) • PROFIBUS modules for Allen-Bradley® SLC™ 500 RoHS Compliant Yes MTBF 81.2 years • PROFIBUS USB Adapter supporting CommDTM / FDT Version 1.2 • PROFIBUS network interface cards (PCIe, PCI, C-PCI, PC/104, ISA, VME) inclusive DLL, OPC, ActiveX… • Full metal PROFIBUS connector ® • • IDC-technique provides quick and error-free connection Optional diagnostic LED reduces downtime Ordering Information Part Number SST-PB3-CLX-RLL SAP Description BradCommunications™ SST™ PROFIBUS Scanner 1120160018 for Allen-Bradley ControlLogix, includes Remote Link Library BradCommunications™ SST™ PROFIBUS Scanner SST-PB3-CLX-DTM 1120160019 for Allen-Bradley ControlLogix, includes Remote Link Library and CommDTM driver license SST-PB3-CLX-DTS 1120160020 BradCommunications™ SST™ CommDTM update driver license for PROFIBUS Scanner To contact us: www.woodhead.com North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136 Europe: France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 – United: Kingdom +44 1495 356300 Asia: Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717 Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950 BradCommunications and SST are trademarks of Molex Incorporated. © 2008 Molex