TDK NLC453232T-1R2K-PF Inductors for decoupling circuits wound ferrite Datasheet

I
N
D
U
C
T
O
R
S
January 2015
Inductors for Decoupling Circuits
Wound Ferrite
NLC Series
NLC453232 Type
NLC453232
4532 [1812 inch]*
* Dimensions Code JIS[EIA]
(2/10)
I
N
D
U
C
T
O
R
S
REMINDERS FOR USING THESE PRODUCTS
Before using these products, be sure to request the delivery specifications.
SAFETY REMINDERS
Please pay sufficient attention to the warnings for safe designing when using these products.
REMINDERS
The storage period is less than 6 months. Be sure to follow the storage conditions (Temperature: 5 to 40°C, Humidity: 10 to 75% RH or
less).
If the storage period elapses, the soldering of the terminal electrodes may deteriorate.
Do not use or store in locations where there are conditions such as gas corrosion (salt, acid, alkali, etc.).
Before soldering, be sure to preheat components.
The preheating temperature should be set so that the temperature difference between the solder temperature and chip temperature
does not exceed 150°C.
Soldering corrections after mounting should be within the range of the conditions determined in the specifications.
If overheated, a short circuit, performance deterioration, or lifespan shortening may occur.
When embedding a printed circuit board where a chip is mounted to a set, be sure that residual stress is not given to the chip due to
the overall distortion of the printed circuit board and partial distortion such as at screw tightening portions.
Self heating (temperature increase) occurs when the power is turned ON, so the tolerance should be sufficient for the set thermal
design.
Carefully lay out the coil for the circuit board design of the non-magnetic shield type.
A malfunction may occur due to magnetic interference.
Use a wrist band to discharge static electricity in your body through the grounding wire.
Do not expose the products to magnets or magnetic fields.
Do not use for a purpose outside of the contents regulated in the delivery specifications.
The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications
equipment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement
equipment, industrial robots) under a normal operation and use condition.
The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or
quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to
society, person or property.
If you intend to use the products in the applications listed below or if you have special requirements exceeding the range or conditions
set forth in the each catalog, please contact us.
(1) Aerospace/Aviation equipment
(2) Transportation equipment (cars, electric trains, ships, etc.)
(3) Medical equipment
(4) Power-generation control equipment
(5) Atomic energy-related equipment
(6) Seabed equipment
(7) Transportation control equipment
(8) Public information-processing equipment
(9) Military equipment
(10) Electric heating apparatus, burning equipment
(11) Disaster prevention/crime prevention equipment
(12) Safety equipment
(13) Other applications that are not considered general-purpose
applications
When designing your equipment even for general-purpose applications, you are kindly requested to take into consideration securing
protection circuit/device or providing backup circuits in your equipment.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm
(3/10)
I
N
D
U
C
T
O
R
S
Inductors for Decoupling Circuits
Product compatible with RoHS directive
Compatible with lead-free solders
Wound Ferrite
Overview of NLC453232 Type
FEATURES
Resin mold type wound inductor for decoupling circuits.
E-12 Series, wide lineup compatible with K (±10%) tolerance allows for various usages.
APPLICATION
Smart meters, AV equipment, xDSL, electronic devices for communications infrastructure such as mobile base stations, industrial
equipment, other
PART NUMBER CONSTRUCTION
NLC
Series name
453232
L×W×H Dimensions
(mm)
453232
4.5×3.2×3.2
T
-
Packaging style
T
Taping
1R0
K
Inductance
(μH)
1R0
1
100
10
101
100
Inductance
tolerance
K
±10%
-
PF
Lead-free
compatible
OPERATING TEMPERATURE RANGE, PACKAGE QUANTITY, PRODUCT WEIGHT
Temperature range
Type
NLC453232
Operating
temperature
(°C)
–40 to +105
Package quantity
Individual weight
(pieces/reel)
500
(mg)
180
Storage
temperature
(°C)
–40 to +105
Operating temperature range includes self-temperature rise.
The Storage temperature range is for after the circuit board is mounted.
RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://product.tdk.com/en/environment/rohs/
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm
(4/10)
I
N
D
U
C
T
O
R
S
NLC453232 Type
RECOMMENDED REFLOW PROFILE
Preheating
Soldering
Natural
cooling
Peak
T: Temperature
T4
T3
T2
T3
t3
T1
t1
t2
t: Time
Preheating
Temp.
T1
T2
150°C
180°C
Time
t1
90 to 120s
Soldering
Temp.
Time
T3
t2
230°C
40s
Peak
Temp.
T4
255°C
Time
t3
10s max.
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm
(5/10)
I
N
D
U
C
T
O
R
S
NLC453232 Type
SHAPE & DIMENSIONS
120
2.6±0.1
3.2±0.2
R0.2
C0.5
0.5
(0.6)
(3.3)
(0.6)
3.2±0.2
4.5±0.3
Dimensions in mm
2.8
RECOMMENDED LAND PATTERN
1.5
3
1.5
Dimensions in mm
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm
(6/10)
I
N
D
U
C
T
O
R
S
NLC453232 Type
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS SPECIFICATION TABLE
L
(μH)
1
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
Tolerance
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
Q
L, Q measuring
frequency
DC resistance
Rated current
min.
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
20
20
20
20
20
20
20
(MHz)
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
0.796
0.796
0.796
0.796
0.796
0.796
0.796
(ȍ )max.
0.11
0.12
0.15
0.16
0.18
0.2
0.22
0.24
0.27
0.3
0.35
0.4
0.5
0.6
0.7
0.8
0.9
1.2
1.4
1.6
1.9
2.2
2.6
3.5
4
4.5
6.5
7.5
9
11
13
(mA)max.
1050
1000
950
900
850
800
750
700
650
650
600
600
550
500
450
400
370
330
300
280
260
240
220
200
180
160
140
120
120
100
90
Part No.
NLC453232T-1R0K-PF
NLC453232T-1R2K-PF
NLC453232T-1R5K-PF
NLC453232T-1R8K-PF
NLC453232T-2R2K-PF
NLC453232T-2R7K-PF
NLC453232T-3R3K-PF
NLC453232T-3R9K-PF
NLC453232T-4R7K-PF
NLC453232T-5R6K-PF
NLC453232T-6R8K-PF
NLC453232T-8R2K-PF
NLC453232T-100K-PF
NLC453232T-120K-PF
NLC453232T-150K-PF
NLC453232T-180K-PF
NLC453232T-220K-PF
NLC453232T-270K-PF
NLC453232T-330K-PF
NLC453232T-390K-PF
NLC453232T-470K-PF
NLC453232T-560K-PF
NLC453232T-680K-PF
NLC453232T-820K-PF
NLC453232T-101K-PF
NLC453232T-121K-PF
NLC453232T-151K-PF
NLC453232T-181K-PF
NLC453232T-221K-PF
NLC453232T-271K-PF
NLC453232T-331K-PF
Rated current: smaller value of either Idc1 or Idc2.
Idc1: When based on the inductance change rate (10% below the initial L value)
Idc2: When based on the temperature increase (Temperature increase of 20°C by self heating)
○ Measurement equipment
Measurement item
Product No.
L, Q
4194A+16085A+16093B
DC resistance
VP-2941A
* Equivalent measurement equipment may be used.
Manufacturer
Agilent Technologies
Panasonic
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm
(7/10)
I
N
D
U
C
T
O
R
S
NLC453232 Type
ELECTRICAL CHARACTERISTICS
L FREQUENCY CHARACTERISTICS GRAPH
10000
331K
1000
271K
221K
181K
151K
121K
101K
820K
680K
560K
100
470K
390K
Inductance(μH)
330K
270K
220K
180K
150K
120K
10
100K
8R2K
6R8K
5R6K
4R7K
3R9K
3R3K
1
2R7K
2R2K
1R8K
1R5K
1R2K
1R0K
0.1
0.01
0.1
1
10
100
Frequency(MHz)
○ Measurement equipment
Product No.
Manufacturer
4294A
Agilent Technologies
* Equivalent measurement equipment may be used.
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm
(8/10)
I
N
D
U
C
T
O
R
S
NLC453232 Type
ELECTRICAL CHARACTERISTICS
INDUCTANCE VS. DC BIAS CHARACTERISTICS GRAPH
1000
331K
271K
221K
181K
151K
121K
100
101K
820K
680K
560K
470K
390K
330K
270K
Inductance(μH)
220K
180K
150K
120K
10
100K
8R2K
6R8K
5R6K
4R7K
3R9K
3R3K
2R7K
2R2K
1R8K
1R5K
1R2K
1
0.1
0.01
1R0K
0.1
1
10
DC current(A)
○ Measurement equipment
Product No.
Manufacturer
4285A+42841A+42842C
Agilent Technologies
* Equivalent measurement equipment may be used.
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm
(9/10)
I
N
D
U
C
T
O
R
S
NLC453232 Type
ELECTRICAL CHARACTERISTICS
IMPEDANCE FREQUENCY CHARACTERISTICS GRAPH
1000000
331K
100000
271K
221K
150K
121K
101K
560K
470K
330K
270K
220K
181K
151K
4R7K
5R6K
820K
10000
680K
8R2K
100K
3R9K 3R3K
390K
180K
Impedance(Ω)
1000
1R0K
1R2K
100
1R5K
1R8K
2R2K
2R7K
120K
6R8K
10
1
0.1
0.1
1
10
100
Frequency(MHz)
○ Measurement equipment
Product No.
Manufacturer
4294A
Agilent Technologies
* Equivalent measurement equipment may be used.
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm
(10/10)
I
N
D
U
C
T
O
R
S
NLC453232 Type
PACKAGING STYLE
REEL DIMENSIONS
2.0±0.5
E
Type
NLC453232
A
ø180
W1
13
W2
17
N
ø60
E
0.5
N
* These values are typical values.
(1.0)
ø13.0±0.5
W1
ø21.0±0.8
W2
A
Dimensions in mm
TAPE DIMENSIONS
P2
P0
K
P1
A
Type
NLC453232
A
3.6
B
4.9
øD0
1.5+0.1/-0
B
W
F
E
øD0
t
Dimensions in mm
E
F
P0
P1
P2
W
1.75±0.1 5.50±0.05 4.00±0.10 8.00±0.10 2.00±0.05 12.0±0.30
K
3.2
t
0.4
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20150105 / inductor_commercial_decoupling_nlc453232_en.fm