AMEPR25D-24100AZ up to 1A | AC-DC LED Driver FEATURES: AC-DC Constant Current LED Driver Input Range 90-264VAC/47-440Hz Active PFC with TRIAC Dimmable② Operating Temperature -20 to 80°C Total Harmonic Distortion < 20% IP67 Case High Efficiency up to 83% SCP, Over Load Protection Leading or Trailing Edge Triac Models Single Output Model AMEPR25D-24100AZ Max Output Power (W)① Output Voltage Range (V) No Load Output Voltage (V max.) Output Current (A) Input Voltage (VAC/Hz) 24 9-24 35 1 90-264/ 47-440 Input Voltage (VDC) 130-370 Efficiency (%) 115 230 VAC VAC 80 83 Exceeding the maximum output power will permanently damage the converter. Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Conditions Typical 115VAC 230VAC 115VAC 230VAC 260 150 8 13 0.25 0.9 0.9 Leakage current Power factor External fuse Start-up time Maximum 115VAC 230VAC Recommended slow blow type 1 100 Units mA mA A A mA A ms Output Specifications Parameters Current accuracy Line regulation Load regulation Ripple & Noise * Hold-up time Maximum Capacitive load Conditions Typical Maximum ±15 ±20 ±15 2 16 (LL-HL) 0-100% load 47 * Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. Units % % % V p-p ms µF Isolation Specifications Parameters Tested I/O voltage Isolation resistance www.aimtec.com F 052.1e R3.A Conditions Typical 60sec/10mA >1000 Tel: +1 514 620 2722 1 of 4 Maximum Units 3000 VAC MΩ Toll free: + 1 888 9 AIMTEC (924 6832) North America only AMEPR25D-24100AZ up to 1A | AC-DC LED Driver General Specifications Parameters Conditions Switching frequency Over load protection Over voltage protection Short circuit protection Operating temperature Storage temperature Maximum case temperature Temperature coefficient Cooling Humidity Case material Wires Weight Dimensions (L X H X W) MTBF Typical Maximum 60 ≧110 ≧110 Auto recovery Refer to model application -40 to +95 With derating over 55 °C Units KHz % % oC oC oC % / oC 100 ±0.02 Free air convection Non condensing 20~95 Plastic UL1015 Input 18AWG*10CM/ Output 20 AWG * 10CM 150 133 x 33 x 30mm (5.24 x 1.30 x 1.18inches) >400,000 hrs (MIL-HDBK-217F at t=+25°C) % RH g Environment Approval Test Shock Vibration Parameters Conditions Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Half sine wave 5gn 30ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards cULus, CE, CFF EN61347-1, EN61347-2-13, IEC62384, UL8750, UL60950-1, EN55015, EN55024 Radiated and Conducted Emission FCC Part 15 Subpart B, Class B, ANSI C63.4 :2003 EMI - Conducted and radiated emission EN55022 Harmonic Current Emissions IEC/EN 61000-3-2, (EN60555-2) Voltage Fluctuations and Flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 2 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power Frequency Magnetic Field Immunity IEC 61000-4-8 Level 2 Voltage Dips, Short Interruptions Immunity IEC 61000-4-11 Wire Specifications Wire Input Output Parameters Color ACN ACL +V Output -V Output Blue Brown Red Black www.aimtec.com F 052.1e R3.A Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only AMEPR25D-24100AZ up to 1A | AC-DC LED Driver Dimensions £X 1.00 (£ X 0.04) ¡ Ó ¡ Ó Derating Free Air Convection 100 55 ºC 80 Safe Operating Area 60 50 40 25 20 0 -40 -20 0 20 40 55 60 70 80 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.A Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only AMEPR25D-24100AZ up to 1A | AC-DC LED Driver Triac Dimming Feature NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 6. The Dimming performance is based on typical value of input. www.aimtec.com F 052.1e R3.A Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only