POWER AIF Series 600 Watts Data Sheet Total Power: 600 Watts (12 V @ 50 A) Input Voltage: 300 V # of Outputs: Single SPECIAL FEATURES 600 W continuous power at 100 °C baseplate temperature 108 W/in3 (6.6 W/cm3) High efficiency - up to 90% Low output ripple and noise Positive and Negative enable function Excellent transient response OVP, OCP, V Adj control with ALPTM analog mode linear control, or through I2C bus with digital mode control Paralleable with accurate current sharing EU Directive 2002/95/EC compliant for RoHS Two year warranty SAFETY UL cUL TUV CE 60950 Recognized 60950 Recognized EN60950 Licensed CE Mark Electrical Specifications Input Input range 250 - 420 VDC Input surge 450 V / 100 ms Efficiency 90% @ 5.0 V (Typical) Output Load Regulation 0.2% typical down to no load Line Regulation 0.2% typical Noise / Ripple 100 mV typical (below 5 V); 2% typical (5 V and above) Remote sense Up to 0.5 V Output voltage adjust range +/-20% for 5V and above; +10%/-50% for below 5 V Transient Response 5% max for 3.3 V and above, 150 mV for 1.8V , deviation with 25% to 75% full load 250 μS (max) recovery Current Share Accuracy 3% typical Overvoltage Protection 115% Vo (nominal) Current Limit 115% Io maximum Control Voltage Adjust 80 to 120% Vo linear programming for 12 V, 15 V, 24 V, 48 V 50% to 110% for 1.8 V - 5.0 V Enable TTL compatible (positive & negative enable options) Current Limit Adjust 20 to 100% Io linear programming or digital mode control Clock Input (external sync) 3.3 to 5.5 Vp-p @ 800 KHz ±10% Clock Output (internal clock) 4.5 Vp-p typical@ 800 KHz ±5% Power Good Identification High (Vo) = power good Temperature Monitor Output 10 mV/°K (2.73 = 0°C) Current Monitor Output 0 to 1 mA (1 mA = 100% Io rated) Over Voltage Protection Adjust 110 to 150% Vo linear programming by voltage or resistor, or digital mode control Notes: Nominal values apply with sense pins connected and other control pin unconnected. ALP: Astec Linear Programming AIF Series Data Sheet Environmental Specifications Operating temperature -20 °C to +100 °C (case temperature) Start up temperature -40 °C to +100 °C (case temperature) Storage temperature -40 °C to +125 °C Overtemperature protection 110 °C max Ordering Information Input Voltage Output Voltage Efficiency Model Number 300 V 1.8 V @ 120 A 80% (Typ) AIF120Y300 300 V 3.3 V @ 120 A 87% (Typ) AIF120F300 300 V 5.0 V @ 80 A 90% (Typ) AIF80A300 300 V 12 V @ 50 A 90% (Typ) AIF50B300 300 V 15 V @ 40 A 90% (Typ) AIF40C300 300 V 24 V @ 25 A 90% (Typ) AIF25H300 1. For Negative enable, add suffix “-N”. 2. For Non-thread hole, add suffix “-NT”. 3. For RoHS 6, add suffix “-L”. Default is RoHS 5. Pin Assignments Input (AC) Output (DC) Control Pins 31. Positive 21. Positive 1. +Sense 32. Negative 22. Positive 2. Temp Mon 23. Positive 3. C Mon 24. Positive 4. C Share 25. Negative 5. Clk Out 26. Negative 6. Clk In 27. Negative 7. PG/ID 28. Negative 8. C Lim Adj 9. OVP Adj 10. V Adj 11. Enable 12. -Sense AIF Series Data Sheet Mechanical Drawings WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong +852 2176 3333 While every precaution has been taken to ensure accuracy and completeness in this literature, Artesyn Embedded Technologies assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. © 2015 Artesyn Embedded Technologies, Inc. www.artesyn.com For more information: www.artesyn.com/power For support: [email protected] AIF Series-DS 24Mar2015