COMMANDER CLASS - CHASSIS MOUNT WITH LEAD WIRES POWER TRANSFORMER 1. Standard 6” Lead Length 2. 3. Electrical Specifications A. Maximum Power: 12VA B. Input Voltage and Frequency: 115V, 115/230V or 230V 50/60Hz C. Voltage Regulation: 18% TYP @ full load to no load D. Temperature Rise: 30C TYP E. Insulation Resistance: < 1 MEG ohm F. Hi-Pot: 2500Vrms 1 minute @ Pri to Sec 2500Vrms 1 minute @ Pri to Core 1500Vrms 1 minute @ Sec to Core Marking: Ensign Corp, part number (see table), date code Safety: UL/cUL 5085-2 Recognized (File E47299) UL 1446 Recognized Insulation System (File E95662) Part Number Primary Schematics Single Input (Specify 115V or 120V Single Input (Specify 230V or 240V) Single Input (277V) Tapped Input WHT=COM BLK=120 VIO=277V Dual Input (Specify 115/230V or 120/240V) 115V 115/230V 230V Secondary L012-1-510X L012-2-510X L012-3-510X 10VCT @ 1.2A L012-1-512X L012-2-512X L012-3-512X 12.6VCT @ 1.0A L012-1-516X L012-2-516X L012-3-516X 16VCT @ 800mA L012-1-520X L012-2-520X L012-3-520X 20VCT @ 600mA L012-1-524X L012-2-524X L012-3-524X 24VCT @ 500mA L012-1-528X L012-2-528X L012-3-528X 28VCT @ 420mA L012-1-536X L012-2-536X L012-3-536X 36VCT @ 350mA L012-1-548X L012-2-548X L012-3-548X 48VCT @ 250mA L012-1-556X L012-2-556X L012-3-556X 56VCT @ 220mA L012-1-620X L012-2-620X L012-3-620X 120VCT @ 100mA Secondary Schematics POWER TRANSFORMER COMMANDER CLASS CONTENTS OF THIS DRAWING ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE Single Output Center-Tapped Output Dual Output Ensign Corporation L012-1-XXXX L012-2-XXXX L012-3-XXXX Dim: Inches Sheet 1 of 1 201 ENSIGN RD., BELLEVUE, IA 52031 PROPRIETARY NOTICE: THIS DRAWING PRINT OR DOCUMENT AND SUBJECT MATTER DISCLOSED HEREIN ARE PROPRIETARY ITEMS TO WHICH ENSIGN RETAINS THE EXCLUSIVE RIGHT OF DISSEMINATION, MANUFACTURE AND SALE. THIS DRAWING, PRINT OR DOCUMENT IS SUBMITTED IN CONFIDENCE FOR CONSIDERATION BY THE RECIPIENT ALONE UNLESS PERMISSION FOR FURTHER DISCLOSURE IS EXPRESSLY GRANTED IN WRITING