Présente / Presents: DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com JZC-36F NHG RELAYS JZC-36F Operation condition Insulation Resistance 1000M Dielectric Strength Between contacts Between contact and coil US R158859 Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass Features Heavy load, suitable for heavy power reverse. Small size, suitable for high-density mounting.. Suitable for remote control TV set, copy machine, sales machine and air conditioner etc. Item 6 of IEC255-5 Item 6 of IEC255-5 Item 8 of IEC255-5 Functional 200m/s2 11ms Survival 1000m/s2 11ms 10~55Hz amplitude 1.5mm 10N 235 2 3 0.5s -40~70 35%~85% (at 40 ) 12g Shock resistance Patent NO.:200420081938.2 24.5 10.5 25.0 Item 7 of IEC255-5 50Hz 1000V 50Hz 3000V 4000V Surge Voltage 10kV R C min (at 500VDC) IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca Qualification inspection: Perform the qualification test as specified in the table Ordering Information 4 5 6 1 Part number JZC-36F 2 Contact arrangement A:1A C:1C 3 Enclosure S:Sealed type Z:Dust cover 4 Contact current:10A 5 Coil rated voltage(V):DC:5,6,9,12,18,24,48 6 Coil power consumption:0.25:0.25W;0.53:0.53W Dimensions Contact Data Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operational Electrical Life Mechanical 1A (SPSTNO) 1C (SPDT(B-M)) AgSnO2 10A/250VAC,30VDC TV-5 330W 2500VA 30VDC 277VAC 100m 105 10 7 mm /inch 3.5 0.138 10.5max. 0.413max. 24.5max. 1max. 16.5 0.650 0.5 0.020 Contact Arrangement Contact Material AgCdO Contact Rating (resistive) UL & CUR 10A/250VAC,30VDC;TV-5 Max. Switching Current:10A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 2 0.079 0.8 0.031 Coil Parameter 7. 5 0.295 3 Safety approval Load DC12V 0.25 7. 5 0.295 2 10 25max. 0.984max. 1 S 4 0.3 0.157 0.012 JZC-36F C of IEC255-19-1 and minimum sample size 24. Safety approvals 0.5 0.020 0.5 0.020 Coil voltage VDC Coil resistance 10% Pick up voltage VDC (max) (75% of rated voltage ) Release voltage VDC (min) (5% of rated voltage) Coil power consumption W Rated Max 005-250 006-250 009-250 012-250 018-250 024-250 048-250 5 6 9 12 18 24 48 6.5 7.8 11.7 15.6 23.4 31.2 62.4 100 145 325 575 1300 2310 9210 3.75 4.50 6.75 9.00 13.5 18.0 36.0 0.25 0.30 0.45 0.60 0.90 1.2 2.4 0.25 005-530 006-530 009-530 012-530 018-530 024-530 048-530 5 6 9 12 18 24 48 6.5 7.8 11.7 15.6 23.4 31.2 62.4 47 68 155 270 620 1080 4400 3.75 4.50 6.75 9.00 13.5 18.0 36.0 0.25 0.30 0.45 0.60 0.90 1.2 2.4 0.53 Operate Time ms 1A 16.5 0.650 3.5 0.138 5- 1.3 0.051 3.5 0.138 1C Dimensions Dash numbers 4- 1.3 0.051 Mounting (Bottom view) Release Time ms 1A 1C Wiring diagram (Bottom view) 15 5 NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Reference Data 15 5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Tolerance: 0.1/ 0.004 Ningbo Forward Relay Corporation LTD. 66 JZC-36F JZC-36F Operation condition Insulation Resistance 1000M Dielectric Strength Between contacts Between contact and coil US R158859 Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass Features Heavy load, suitable for heavy power reverse. Small size, suitable for high-density mounting.. Suitable for remote control TV set, copy machine, sales machine and air conditioner etc. Item 6 of IEC255-5 Item 6 of IEC255-5 Item 8 of IEC255-5 Functional 200m/s2 11ms Survival 1000m/s2 11ms 10~55Hz amplitude 1.5mm 10N 235 2 3 0.5s -40~70 35%~85% (at 40 ) 12g Shock resistance Patent NO.:200420081938.2 24.5 10.5 25.0 Item 7 of IEC255-5 50Hz 1000V 50Hz 3000V 4000V Surge Voltage 10kV R C min (at 500VDC) IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca Qualification inspection: Perform the qualification test as specified in the table Ordering Information 4 5 6 1 Part number JZC-36F 2 Contact arrangement A:1A C:1C 3 Enclosure S:Sealed type Z:Dust cover 4 Contact current:10A 5 Coil rated voltage(V):DC:5,6,9,12,18,24,48 6 Coil power consumption:0.25:0.25W;0.53:0.53W Dimensions Contact Data Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operational Electrical Life Mechanical 1A (SPSTNO) 1C (SPDT(B-M)) AgSnO2 10A/250VAC,30VDC TV-5 330W 2500VA 30VDC 277VAC 100m 105 10 7 mm /inch 3.5 0.138 10.5max. 0.413max. 24.5max. 1max. 16.5 0.650 0.5 0.020 Contact Arrangement Contact Material AgCdO Contact Rating (resistive) UL & CUR 10A/250VAC,30VDC;TV-5 Max. Switching Current:10A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 2 0.079 0.8 0.031 Coil Parameter 7. 5 0.295 3 Safety approval Load DC12V 0.25 7. 5 0.295 2 10 25max. 0.984max. 1 S 4 0.3 0.157 0.012 JZC-36F C of IEC255-19-1 and minimum sample size 24. Safety approvals 0.5 0.020 0.5 0.020 Coil voltage VDC Coil resistance 10% Pick up voltage VDC (max) (75% of rated voltage ) Release voltage VDC (min) (5% of rated voltage) Coil power consumption W Rated Max 005-250 006-250 009-250 012-250 018-250 024-250 048-250 5 6 9 12 18 24 48 6.5 7.8 11.7 15.6 23.4 31.2 62.4 100 145 325 575 1300 2310 9210 3.75 4.50 6.75 9.00 13.5 18.0 36.0 0.25 0.30 0.45 0.60 0.90 1.2 2.4 0.25 005-530 006-530 009-530 012-530 018-530 024-530 048-530 5 6 9 12 18 24 48 6.5 7.8 11.7 15.6 23.4 31.2 62.4 47 68 155 270 620 1080 4400 3.75 4.50 6.75 9.00 13.5 18.0 36.0 0.25 0.30 0.45 0.60 0.90 1.2 2.4 0.53 Operate Time ms 1A 16.5 0.650 3.5 0.138 5- 1.3 0.051 3.5 0.138 1C Dimensions Dash numbers 4- 1.3 0.051 Mounting (Bottom view) Release Time ms 1A 1C Wiring diagram (Bottom view) 15 5 NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Reference Data 15 5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 65 Tolerance: 0.1/ 0.004 Ningbo Huaguan Relay Corporation LTD.