Coto B10-05 Rf relay Datasheet

B10 RF Relays
Ball Grid Array Relays
Coto’s Ball Grid Array (BGA) construction offers a breakthrough in
reed relay performance. This patented technology1 allows for shorter
RF paths in a controlled 50 Ω environment to minimize signal
attentuation. The designer is now able to switch or pass signals with
wider bandwidth and faster rise time than alternative technologies.
This is particularly important in Mixed Signal IC testers. BGA packaging allows relays to be integrated easily on boards designed for surface
mount processing.
Series Features
BGA Surface Mount
Ability to pass GHz signals
Rise time < 40ρSec
50Ω Characteristic Impedance
Low Capacitance
1
Patented Design
Applications
IC Testers
In-Line Relay Testers
Memory Testers
Mixed Signal Testers
High Bandpass Applications
Dimensions in Inches
(Millimeters)
Notes:
1
Protected by one or more of the following
US Patents: 6025768, 6052045, 6294971,
6683518, RE38381 and other foreign patents.
40
COTO TECHNOLOGY (USA) Tel: (401) 943-2686 / Fax (401) 942-0920
6
(Europe) Tel: +31-45-5439343 / Fax +31-45-5427216
B10 RF Relays
Test Parameters
Coil Resistance
Nominal Voltage
Must Operate Voltage
Must Release Voltage
Coil Resistance
Nominal Voltage
Must Operate Voltage
Must Release Voltage
Switching Voltage
Switching Current
Carry Current (Continuous)
Contact Rating (Resistive Load)
3
Life Expectancy Signal Switching
3
Resistive Load
Other Load Conditions3
Static Contact Resistance (initial)
Dynamic Contact Resistance (initial)
Insulation Res
All Isolated Pins
Capacitance
Across Contacts
Capacitance
Open Contact to Coil
Capacitance
Closed Contact to Coil
Across Contacts
Dielectric
Contact to Coil
Strength
Contact to Shield
Operate Time
(including bounce)
Release Time
(Si diode damped)
4
RF Insertion Loss
Signal Rise Time (10% - 90%)
1,2
Conditions
Min
49.5
3.3V Coil
0.4
135.0
5V Coil
B10
Typ
Max
Units
55.0
5.0
60.5
4.0
2.4
150.0
5.0
165.0
6.0
3.8
Ω
Volts DC
Volts DC
Volts DC
Ω
Volts DC
Volts DC
Volts DC
Volts
Amps
Amps
Watts
6
x 10 Ops
x 106 Ops
0.4
Max DC/Peak AC
Switch and Shield
Resistive Load
1VDC / 10mA
12VDC / 10mA
Consult Factory
0.05VDC / 10mA
0.5V / 50mA 100 Hz, 1.5 mSec
100VDC
Shield Guarding
Shield Guarding
Shield Guarding
100 µA
100 µA
100 µA
Nominal Voltage coil drive @ 30 Hz,
square wave
-3 dB roll-off frequency
Corrected for measurement
system response time
125
0.25
0.5
3.0
1000
1
10!10
0.125
0.150
Ω
Ω
Ω
pF
pF
pF
V (DC/Pk AC)
V (DC/Pk AC)
V (DC/Pk AC)
200
50
µSec
µSec
GHz
pSec
10 12
0.2
0.5
1
150
1500
1500
100
30
10.0
40
NOTES:
1
All parameters specified per EIA/NARM standards
for dry reed relays, # RS-421 and RS-436, if a
suitable parametric standard exists.
2
Unless otherwise noted, all parameters are specified
at 25°C and 40% RH.
3
Life expectancies based on characteristic life
(63.2% failure) calculated from the 2-parameter
Weibull distribution. Contact resistance >2.0Ω
defines end of life.
4
Frequency at which the difference between output
and input signal amplitude exceeds -3dB. (Direct
wired using 50Ω coaxial cable.)
ENVIRONMENTAL RATINGS:
Storage Temperature: -35°C to +100°C.
Operating Temperature: -20°C to +85°C.
Vibration: sinusoidal vibration with an amplitude of
10G over a 10Hz to 2000Hz frequency range shall
not cause a closed channel activated at the nominal
coil voltage to open, not an open channel to close.
Max Soldering Temperature: 226°C (438°F) max for
1 minute dwell time. Temperature measured at a
relay ball termination.
For Most Recent Data, Consult the Coto Technology Website: www.cotorelay.com
6
E-mail: [email protected]
41
Similar pages