XP Power ISA0305 Dc-dc converter Datasheet

ISA Series
DC-DC Converter
1 Watt
xxx Series
• Dual Output
• SMD Package
• Industry Standard Pinout
• Operating Temperature 40 °C to +105 °C
• 1500 VDC Isolation, 3000 VDC Option
• 3 Year Warranty
Dimensions:
ISA:
0.600 x 0.440 x 0.285” (15.24 x 11.20 x 7.25 mm)
Models & Ratings
Input Voltage
Output Voltage
±5
±12
±15
±5
±9
±12
±15
±24
±5
±9
±12
±15
±24
±15
±5
±9
±12
±15
±24
2.97-3.63 V
4.5-5.5 V
10.8-13.2 V
13.5-16.5 V
21.6-26.4 V
Input Current(2)
No Load
Full Load
Output Current
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
±100
±42
±33
±100
±56
±42
±33
±21
±100
±56
±42
±33
±21
±33
±100
±56
±42
±33
±21
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
25
25
25
20
20
20
20
20
15
15
15
15
15
12
10
10
10
10
10
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
389
389
389
250
250
247
247
247
104
104
103
103
103
83
52
52
51
51
51
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
Maximum
Capacitive Load
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
Efficiency(3)
Model Number
78%
78%
78%
80%
80%
81%
81%
81%
80%
80%
81%
81%
81%
81%
80%
80%
81%
82%
82%
ISA0305(1)
ISA0312(1)
ISA0315
ISA0505(1)
ISA0509(1)
ISA0512(1)
ISA0515(1)
ISA0524(1)
ISA1205(1)
ISA1209(1)
ISA1212(1)
ISA1215(1)
ISA1224(1)
ISA1515(1)
ISA2405(1)
ISA2409(1)
ISA2412(1)
ISA2415(1)
ISA2424(1)
Notes
1. For optional 3000 VDC isolation add suffix ‘-H’ to end of part number e.g.
ISA1224-H.
2. Input currents measured at nominal input voltage.
3. Typical value at full load.
Mechanical Details
Recommended Footprint
Top View grid: 0.1 x 0.1 in (2.54 x 2.54 mm)
Top View
0.276
(7.00)
0.285
(7.25)
0.327
(8.30)
0.441
(11.20)
0.600 (15.24)
1
0.100 0.010
(2.54) (0.25)
0.400
(10.16)
7
10
Side View
0.039
(1.00)
2
4 5
0.400
(10.16)
0.480
(12.20)
A
A
0.035
(0.88)
1
0.010
(0.25)
5 .00 º
www.xppower.com
PIN CONNECTIONS
Pin
Function
1
GND
2
+Vin
4
0V
5
-Vout
7
+Vout
10
No Connection
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.004 lbs (1.8 g) typical.
3. Pin diameter: 0.02 ±0.002 (0.5 ±0.005)
4. Pin pitch and length tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
ISA Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Minimum
Maximum
Units
Notes & Conditions
2.97
Typical
3.63
VDC
3.3 V nominal
4.50
5.50
VDC
5 V nominal
10.80
13.20
VDC
12 V nominal
13.50
16.50
VDC
15 V nominal
21.60
26.40
VDC
Input Current
Input Reflected Ripple
15
Input Surge
Input Filter
24 V nominal
See Models and Ratings table
5
9
mA pk-pk
VDC for 15 ms
VDC for 15 ms
Through 12 µH inductor and 47 µF capacitor
3.3 V models
5 V models
18
VDC for 15 ms
12 V models
21
VDC for 15 ms
15 V models
30
VDC for 15 ms
24 V models
Maximum
Units
±24
VDC
±2
%
Dual output models
%
At 100% load
Capacitor
Output
Characteristic
Minimum
Output Voltage
±5
Typical
Output Voltage Balance
Initial Set Accuracy
Minimum Load
±3.0
10
See Models and Ratings table
%
Line Regulation
±1.2
Load Regulation
Cross Regulation
Start Up Delay
Notes & Conditions
%
%
See graph
±5.0
%
Dual output models when one load is varied between 25% and
100% and the other is fixed at 100% load
60
mV pk-pk
2
ms
Ripple and Noise
Transient Response
3
% deviation
20 MHz bandwidth, measured using 0.1 µF capacitor
Recovery to within 1% in 500 µs for a 25% load change (5%
max. deviation for 3.3 & 5 V models)
Continuous, with auto recovery, except 1 s max for
24 input V models
Short Circuit Protection
Maximum Capacitive Load
Temperature Coefficient
0.02
%/˚C
Maximum
General
Characteristic
Units
Notes & Conditions
Efficiency
Minimum
Typical
See Models and Ratings table
Isolation: Input to Output
VDC
For optional high isolation versions, 3000 VDC input to
output add suffix -H to model number
1500
Switching Frequency
50
Isolation Resistance
109
Isolation Capacitance
kHz
Input to output
13
pF
Win3
kHrs
MIL-HDBK-217F, +25 °C GB
20
Power Density
Mean Time Between Failure
300
3500
Weight
0.004 (1.8)
Ω
Input to output, tested at 500 VDC
lb (g)
Environmental
Characteristic
Minimum
Operating Temperature
-40
Storage Temperature
-55
Typical
Maximum
Units
+105
°C
+125
°C
Case Temperature
+105
°C
Operating Humidity
95
% RH
Cooling
Notes & Conditions
Derate from 100% load at +100 °C to 80% load at 105 °C
Non-condensing
Natural convection
www.xppower.com
2
ISA Series
DC-DC Converter
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55022
Class B
Notes & Conditions
See Application Note for Class B filter
Radiated
EN55022
Class B
See Application Note for Class B filter
Phenomenon
Standard
Test Level
Criteria
ESD Immunity
EN61000-4-2
3
B
EMC: Immunity
Notes & Conditions
Radiated Immunity
EN61000-4-3
3 V/m
A
EFT/Burst
EN61000-4-4
2
B
External input capacitor required, 330 µF/100 V
Surge
EN61000-4-5
2
B
External input capacitor required, 330 µF/100 V
Conducted Immunity
EN61000-4-6
3 V rms
A
Magnetic Fields
EN61000-4-8
1 A/m
A
Load Regulation
Output Voltage Accuracy (%)
110
105
Typical Lo
ad Curve
+2.5%
100
-2.5%
-7.5%
0
50
70
100
Load (%)
For all other models
Application Note
EMI Filter for Class B Emissions
6.8 µH
+ Vout
+ Vin
C
ISA
4.7 µF, 50 V
0V
C
-Vin
3
-Vout
www.xppower.com
Output Voltage
C1
±5
4.70 µF
±9
2.20 µF
±12
1.00 µF
±15
1.00 µF
±24
0.47 µF
01Dec14
Similar pages