ETC1 A2475 Zero voltage and random turn-on switching Datasheet

Series 1
10-90Amp • 120, 240 Vac • AC Output
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• 600V Blocking Capability
• Internal Snubber
• 110 & 125A Models
Available
A1210
D1210
A1225
D1225
A1240
D1240
A2410
D2410
A2425
D2425
A2450
D2450
A2475
D2475
A2490
D2490
24-140
24-140
24-140
24-280
24-280
24-280
24-280
24-280
Max. Load Current ➂ [Arms]
10
25
40
10
25
50
75
90
Min. Load Current, [mArms]
40
40
40
40
40
40
40
40
Transient Overvoltage [Vpk]
400
400
400
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
120
250
625
120
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.48
1.02
0.63
1.48
1.02
0.63
0.31
0.28
60
260
1620
60
260
1620
4150
6000
8
8
8
10
10
10
10
10
500
500
500
500
500
500
500
500
0.5
0.5
MODEL NUMBERS
AC CONTROL
D C C ONTROL
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross, random turnon (phase controllable) and normally
closed (Form B) versions with either
AC or DC input (coil) control.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Thermal Resistance Junction to Case (RθJC) [˚C/W]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-On Time
➃
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec(AC Control)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
0.5
0.5
0.5
0.5
0.5
DC CONTROL
AC CONTROL
AC CONTROL
Control Voltage Range
3-32 Vdc
90-280 Vrms (60Hz)
18-36 Vrms
Max. Reverse Voltage
-32 Vdc
---
---
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
18 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
4.0 Vrms
1500 Ohms
60K Ohms
9.0K Ohms
3.4mA @ 5 Vdc, 20mA @ 28Vdc
2mA @ 120 Vrms, 4mA @ 240 Vrms
3mA @ 24 Vrms
(E SUFFIX)
Nominal Input Impedance
Typical Input Current
©1998 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25ºC unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
FastFax Document No. 151
SERIES1.032698, PAGE 1 OF 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
Series 1
10-90Amp • 120, 240 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
AVAILABLE OPTIONS
-B
Normally Closed (Form B)
Example: D2450-B, A2450-B
4D
E
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
400 Hz Operation
10-50 Amp Models Only
Zero Cross Switching Only
Example: 4D2450
1
1.87
(47.5)
24 Vac Input (18-36 Vac)
Example: A2450E
-10
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: D2450-10
F
Faston Terminals (Up to 50A Models)
.250 x .032 Faston Terminals
Example: D1225F
Screws and Saddle Clamps Furnished, Unmounted
+
2.30
(58.4)
1.70
(43.2)
3
INPUT
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
OUTPUT
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
2
1.87
(47.5)
2.30
(58.4)
1.70
(43.2)
4
BASE PLATE
.125 (3.2)
FastFax Document No.151
SERIES1.032698, PAGE 2 OF 3
2
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
1
UL
E116949
CSA LR81689
VDE 10143 UG (Not Applicable: -B and 4D)
OUTPUT
SOLID-STATE RELAY
4
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
APPROVALS
8-32 TERMINAL
(2 PLACES )
--
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays.
Request Crydom’s Heat Sink specification sheet for all the details.
1.10
(27.9)
.45
(11.4)
INPUT
1.00
(25.4)
1.80
(45.7)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
Series 1
10-90Amp • 120, 240 Vac • AC Output
CURRENT DERATING CURVES
10A
25A
12
30
110
5ºC/W
8
NO HEATSINK
115
4
120
25
100
3ºC/W
2ºC/W
20
15
110
10
NO HEATSINK
5
0
6
8
10
50A
40
60
80
5
.5ºC/W
80
1ºC/W
110
40
20
40
60
80
Power Dissipation
100
Base Plate Temp [ºC]
.3ºC/W
.5ºC/W
60
80
90
.2ºC/W
.4ºC/W
80
100
1ºC/W
110
40
120
120
0
Max Ambient Temp. [ºC]
40
90A
120
NO HEATSINK
0
50
20
Max Ambient Temp. [ºC]
120
95
Power Dissipation
110
20
40
25
.5ºC/W
Base Plate Temp [ºC]
100
2ºC/W
30
20
90
40
20
15
75A
1.5ºC/W
Load Current [Arms]
10
Load Current [Arms]
120
1ºC/W
Power Dissipation
20
Max Ambient Temp. [ºC]
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [ºC]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [ºC]
©1998 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.151
SERIES1.032698, PAGE 3 OF 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
Base Plate Temp [ºC]
4
Load Current [Arms]
10
120
0
2
60
Base Plate Temp [ºC]
1ºC/W
Power Dissipation
9ºC/W
95
3ºC/W
Base Plate Temp [ºC]
Power Dissipation
7ºC/W
Similar pages