IQD CFPV-115 Vcxo specification Datasheet

VCXO Specification
CFPV-115
ISSUE 4; June 2016
Description
Standard 3.2 x 2.5mm Voltage Controlled Crystal Oscillator
(VCXO)
Ceramic package with a seam sealed metal lid, hermetically
sealed
Frequency Parameters
Frequency
Frequency Stability
6.0MHz to 54.0MHz
±25.00ppm to ±100.00ppm
Electrical Parameters
Supply Voltage
Start Up Time: 10ms max
3.3V ±5%
Frequency Adjustment
Pulling
±80ppm min
Control Voltage
1.65V ±1.65V
Outline (mm)
Input Impedence
1MΩ min
Linearity: ±10% max, positive slope
Modulation Bandwidth: 20kHz min
Operating Temperature Ranges
-10 to 70°C
-40 to 85°C
Output Details
Output Compatability
Drive Capability
HCMOS
15pF max
Noise Parameters
Phase Noise (typical @ 21.25MHz)
-60dBc/Hz @ 10Hz
-90dBc/Hz @ 100Hz
-125dBc/Hz @ 1kHz
-145dBc/Hz @ 10kHz
-150dBc/Hz @ 100kHz
Environmental Parameters
Storage Temperature Range: -40 to 85°C
Shock: MIL-STD-202F, Method 213B: 1000G, 0.5ms, 1/2 sine
wave
Vibration: MIL-STD-202F, Method 204D, Test Condition D:
20G (10Hz-2000Hz), 4hrs in 3 mutually perpendicular planes
(total 12hrs)
Ordering Information
Frequency*
Model*
Output
Frequency Stability (over operating temperature range)*
Operating Temperature Range*
Supply Voltage
Pullability
(*minimum required)
Example
10.0MHz CFPV-115
HCMOS ±50ppm –40 to 85C 3.3V ±80ppm min
Sales Office Contact Details:
UK: +44 (0)1460 270200
France: 0800 901 383
Germany: 0800 1808 443
USA: +1.760.318.2824
Printed on 31 Aug 16 11:18 using Model Data Sheet V1.2550
Email: [email protected]
Web: www.iqdfrequencyproducts.com
Page 1 of 2
VCXO Specification
CFPV-115
Compliance
RoHS Status (2011/65/EU)
REACh Status
MSL Rating (JDEC-STD-033):
Compliant
Compliant
Not Applicable
Packaging Details
Pack Style: Reel
Pack Size: 1,000
Tape & reel in accordance with EIA-481-D
Pack Style: Cutt
Pack Size: 1
In tape, cut from a reel
Test Circuit
Wave Form
Electrical Specification - maximum limiting values 3.3V ±5%
Frequency
Min
6.0MHz
30.000001MHz
Frequency
Max
30.0MHz
54.0MHz
Temperature
Range
Stability
(Min)
Current
Draw
Rise and Fall
Time
Duty Cycle
°C
ppm
mA
ns
%
-10 to 70
±25.0
15
5
40/60%
-40 to 85
±25.0
15
5
40/60%
-10 to 70
±25.0
25
5
40/60%
-40 to 85
±25.0
25
5
40/60%
This document was correct at the time of printing; please contact your local sales office for the latest version.
Click to view latest version on our website.
Sales Office Contact Details:
UK: +44 (0)1460 270200
France: 0800 901 383
Germany: 0800 1808 443
USA: +1.760.318.2824
Printed on 31 Aug 16 11:18 using Model Data Sheet V1.2550
Email: [email protected]
Web: www.iqdfrequencyproducts.com
Page 2 of 2