Littelfuse A501S002300101 Gas discharge tube - 5x5mm Datasheet

GAS DISCHARGE TUBE
5x5mm
No. A500/A501/A502
Specifications
2-electrode (5kA/5A)
Mini Series
Features
This product is not recommended
for new designs. Please refer to
Littelfuse series SL1002.
Non-radioactive
Lead Free
For limited space applications
Smallest 2-electrode Gas tube
Applications
Packaging
A500:
A501:
A502:
00=Bulk (1.000 pcs.)
01=Reel (1.000 pcs.)
02=Blister Tape (900 pcs.)
Materials
Housing:
Gas:
Leads:
Ceramic
non-radioactive
tin plated
Arc Voltage @ 1A
Telecommunication
Computer Equipment
Sensor Protection
TV Cable Modem
~ 15V
Transition Glow to Arc
@ ~ 0.8A
Standard
UL-497B
complies to ITU-T K.12 (formerly CCITT)
complies to DIN 57845/VDE 0845
Operating temperature
-40°C to +90°C
Approvals
Climatic Category
complies to IEC 60068-1
+40°C, 21 days, <93% humidity
WebLinks
Soldering characteristics
complies to IEC 60068-2-20 (A501)
UL-rec.
Further info see:
http://www.wickmanngroup.com/
download/orderinfo_surgearr.pdf
http://www.wickmanngroup.com/
download/crossref_surgearr.pdf
Soldering Heat Resistance
complies to IEC 60068-2-58
Marking
, Type, Nom. Voltage, Date
Unit Weight
ca. g
Characteristics
Type/
Order Code
DC
Tolerance Impulse
sparkover
sparkover
voltage
voltage
(1kV/µs)
typ.
A500 S0 0090 01 00
A501 S0 0090 01 01
A502 S0 0090 01 02
Glow
Voltage
Insulation
Resistance
(@100 Vdc or
@50Vdc for 90V)
Capacitance
(@1MHZ)
8/20µs
8/20µs
Nominal
Single
Impulse
Impulse
Discharge Discharge
Current
Current
(10 times)
(1 time)
AC
Nominal
Discharge
Current
(50Hz; 1s;
(10 times)
AC
Alternating
Discharge
Current
(50Hz;
9 cycles)
Approval
UL-rec.
90V
+/- 20%
< 550V
~ 60V
> 1GΩ
< 1.0 pF
5kA
10kA
5A
10A
•
A500 S0 0230 01 00
A501 S0 0230 01 01 230V
A502 S0 0230 01 02
+/- 20%
< 600V
~ 60V
> 1GΩ
< 1.0 pF
5kA
10kA
5A
10A
•
A500 S0 0350 01 00
A501 S0 0350 01 01 350V
A502 S0 0350 01 02
+/- 20%
< 800V
~ 60V
> 1GΩ
< 1.0 pF
5kA
10kA
5A
10A
•
A500 S0 0600 01 00
A501 S0 0600 01 01 600V
A502 S0 0600 01 02
+/- 20%
+/- 20%
+/- 20%
< 1.350V
~ 60V
> 1GΩ
< 1.0 pF
5kA
10kA
5A
10A
•
other values on request
Specifications are subject
to change without notice.
Order
Example
050915
Qty.
OrderNumber
WebSite
Europe Tel: +49 2302 662-107
www.wickmanngroup.com E-mail: [email protected]
Type
A500
Failsafe Option Sparkover Volt.
S0
0090
Americas Tel: +1 404 699-7820
E-mail: [email protected]
Tolerance
01
Asia Tel: +852 26 14-1108
E-mail: [email protected]
Packaging
00
China Tel: +86 21 6432 5146
E-mail: [email protected]
GAS DISCHARGE TUBE
Dimensions (mm) A500/A501/A502
A500
Nickel plated
A501
A502
Pad Layout
050915
WebSite
Europe Tel: +49 2302 662-107
www.wickmanngroup.com E-mail: [email protected]
Americas Tel: +1 404 699-7820
E-mail: [email protected]
Asia Tel: +852 26 14-1108
E-mail: [email protected]
China Tel: +86 21 6432 5146
E-mail: [email protected]