Delta DA02D1203A 1w dc/dc converter, smd-package Datasheet

SA01S Sries
1W DC/DC CONVERTER, SMD-Package
FEATURES
Š
Efficiency up to 82%
Š
SMD Package with Industry Standard Pinout
Š
Moisture sensitivity level (MSL) 3
Š
Operating Temperature Range –40° to +85°C
Š
Low ripple and noise
Š
Isolation Voltage 1000 VDC
Š
Lead free, RoHs Compliant
Š
>2 MHours MTBF
Š
3 Years Product Warranty
The SA01S series are miniature, SMD Package, isolated 1W DC/DC converters with 1,000VDC isolation. It offers short circuit
protection and allows a wide operating temperature range of –40°C to +85°C. These isolated DC/DC converters are the latest
offering from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc
Model List
Model
Number
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
3.3
5
9
12
15
3.3
5
9
12
15
3.3
5
9
12
15
SA01S0503A
SA01S0505A
5
SA01S0509A
(4.5 ~ 5.5)
SA01S0512A
SA01S0515A
SA01S1203A
SA01S1205A
12
SA01S1209A
(10.8 ~ 13.2)
SA01S1212A
SA01S1215A
SA01S2403A
SA01S2405A
24
SA01S2409A
(21.6 ~ 26.4)
SA01S2412A
SA01S2415A
Output Current
Input Current
Load
Max. capacitive
Regulation
Load
Max.
Min.
@Max. Load
@No Load
mA
300
200
110
84
67
300
200
110
84
67
300
200
110
84
67
mA
6
4
2
1.5
1
6
4
2
1.5
1
6
4
2
1.5
1
mA(typ.)
264
250
254
252
248
110
103
106
104
102
57
53
54
53
52
mA(typ.)
30
15
8
Efficiency
(typ.)
@Max. Load
% (max.)
10
10
10
8
7
8
8
8
5
5
8
8
8
5
5
uF
33
33
33
%
75
80
78
80
81
75
81
78
81
82
73
79
77
80
80
Input Characteristics
Parameter
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Model
Min.
Typ.
Max.
5V Input Models
4.5
5
5.5
12V Input Models
10.8
12
13.2
24V Input Models
21.6
24
26.4
5V Input Models
-0.7
---
9
12V Input Models
-0.7
---
18
24V Input Models
-0.7
---
30
---
---
0.3
Reverse Polarity Input Current
Input Filter
Internal Power Dissipation
DS_SA01S_03152012
All Models
Unit
VDC
A
Internal Capacitor
---
---
450
mW
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P1
Output Characteristics
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Temperature Coefficient
Short Circuit Protection
Conditions
For Vin Change of 1%
Io=20% to 100%
Min.
-------------
Over Line, Load & Temp.
Typ.
Max.
±1.0
±3.0
±1.2
±1.5
See Model Selection Guide
60
120
--150
--15
±0.01
±0.02
0.5 Second Max.
Unit
%
%
mV P-P
mV P-P
mV rms
%/℃
General Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1000
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
40
100
pF
50
100
140
KHz
2,000,000
---
---
Hours
I/O Isolation Voltage (rated)
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Moisture Sensitivity Level (MSL)
IPC/JEDEC J-STD-020D
Level 3
Recommended Input Fuse
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
24V Input Models
100mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
Max.
-40
+85
--+90
-50
+125
--95
Free-Air convection
--260
Unit
℃
℃
℃
% rel. H
℃
Output Power (%)
Output Power (%)
Power Derating Curve
(5V & 12Vin)
(24Vin)
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Ripple & Noise measurement bandwidth is 0-20MHz.
3
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not
damage these modules; however they may not meet all specifications listed.
4
All DC/DC converters should be externally fused at the front end for protection.
5
Specifications subject to change without notice.
DS_SA01S_03152012
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P2
Mechancial Drawing
5
1
2
3
4
2.54
[0.1]
7.62
[0.3]
7.62 [0.30]
1.7 [0.07]
0~
4
R
0.
5
6
11.2 [0.44]
7
8.0 [0.31]
8
Connecting Pin Patterns
0.3 [0.01]
Mechanical Dimensions (5V & 12V Input)
10.8 [0.43]
( Magnification of A )
6.8 [0.27]
12.7 [0.5]
7.1 0.5
[0.28 0.02]
2.54 [0.10]
S SEATING PLANE
A
7.0 [0.28]
0.3
[0.01]
0.60 [0.02]
0.15 S
9.2 [0.36]
2
3
4
0.25 [0.01]
1
R
2.54
[0.1]
Pin Connections
Pin
0~
4
5
0.
5
6
11.2 [0.44]
7
8.3 [0.33]
Mechanical Dimensions (24V Input)
8
1.0 [0.04]
( Magnification of A )
7.62
[0.1]
12.7 [0.5]
Function
1
-Vin
2
+Vin
3
NA
4
-Vout
5
+Vout
6
NA
7
NA
8
NA
0.60 [0.02]
8.05 0.5
[0.32 0.02]
0.25
[0.01]
7.8 [0.31]
NA : Not Available for Electrical Connection
S SEATING PLANE
A
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
7.4 [0.29]
9.0 [0.35]
0.15 S
X.XX±0.13 ( X.XXX±0.005)
►Pins ±0.05 (±0.002)
Physical Outline
Case Size (5V&12V Input)
Case Size (24V Input)
:
:
12.7x8.0x6.8mm (0.50x0.31x0.27 Inches)
12.7x8.3x7.8mm (0.50x0.33x0.31 Inches)
Case Material
:
Molding (flammability to UL 94V-0 rated)
Weight (5V&12V Input)
Weight (24V Input)
:
:
1.5g
1.8g
DS_SA01S_03152012
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P3
Part Numbering System
S
A
01
S
05
05
A
Form factor
Family series
Watt
Number of
Outputs
Input Voltage
Output Voltage
Option Code
D-DIP
P-SIP
S-SMD
A~Z
01:1W
02:2W
03:3W
04:4W
06:6W
03:3.3V
05: 5V
12:12V
24: 24V
48:48V
03:3.3V
05: 5V
12:12V
15: 15V
24: 24V
A - Std. Functions
S - Single
D- Dual
WARRANTY
Delta offers a three (3) years limited warranty. Complete warranty information is listed on our web site or is available upon request from
Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any
infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under
any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.
DS_SA01S_03152012
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P4