ALM85 Series AC-DC Power Supplies 85 Watts • Medical & IT Safety Approvals • Energy Efficiency Level VI & EU CoC Tier 2 Compliant • 4th Edition Medical EMC • IP32 Environmental Rating • Class I and Class II Versions • <0.15 W Standby Power • 0 °C to 60 °C Operation • Low Earth Leakage Current • 3 Year Warranty Dimensions: The ALM85 series of medical external power supplies is fully approved to international medical & IT safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest environmental legislation. The unit has a fully sealed enclosure complying with IP32 and a smooth surface finish making it easier to wipe down in a clinical setting. ALM85: 5.315 x 2.441 x 1.457” (135.0 x 62.0 x 37.0 mm) Models & Ratings Output Power Output Voltage Output Current 12.0 V 15.0 V 19.0 V 24.0 V 80 W 85 W 6.67 5.33 4.47 3.54 Total Regulation A A A A Model Number(1,2) ALM85US12 ALM85US15 ALM85US19 ALM85US24 ±5% Notes 1. For class II versions, add suffix 'C2-8' to the end of the part number e.g. ALM85US24C2-8. 2. For optional input connector retention clip add suffix ‘-A’ to the model number, e.g. ALM85US24-A (not available for C2 versions) Mechanical Details AC Input IEC 320-C14 -A Versions 5.31 (135.0) 1.58 (40.2) 35.43 ±0.79 (900.0 ±20.0) 1.5 (38.4) AC Input IEC 320-C14 Standard Version 1.46 (37.0) 2.44 (62.0) 1.46 (37.0) 12 &K15 V Versions KPPX-4P (Non-Locking) ø0.685 (17.4) 1.95 ±0.039 (50.0 ±10.0) 0.17 (4.4) AC Input IEC 320-C8 C2-8 Versions 0.37 ±0.012 (9.5 ±0.3) Pin 1 2 3 4 Connection +Vout +Vout RTN RTN 0.039 (1.0) 1.89 (48.0) 19 & 24 V Versions 4.76 (121.0) Return (-) 3.04 (77.2) 1.46 (37.0) Output (+) 1.58 (40.2) Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 0.78 lbs (355 g) approx. 3. For European mains lead order part EU-MAINS-IEC for C14 versions, or EU-MAINS-8 for C8 versions. 4. For UK mains lead order part UK-MAINS-IEC for C14 versions, or UK-MAINS-8 for C8 versions. 1 5. For US mains lead order part US-MAINS-IEC for C14 versions, or US-MAINS-8 for C8 versions. 6. Output connector: 12 V & 15 V: 4 pin power din with pin 1 & 2 - posiitive and pin 3 & 4 - return, equivalent to KPPX-4P (non-locking). 19 V & 24 V: DC barrel jack; 5.5 outer diameter, 2.5 mm inner diameter with centre positive. www.xppower.com ALM85 Series AC-DC Power Supplies Input Characteristic Minimum Input Voltage 80 Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current No Load Input Power Input Protection 47 Typical Units Notes & Conditions 264 VAC Derate linearly from 100% load at 90 VAC to 80% load at 80 VAC. 300 VAC/5 s maximum 63 Hz A A Maximum 1.7/0.9 60/120 250 0.15 T3.15A/250 VAC internal fuse in both line & neutral Measured at 115/230 VAC 115/230 VAC, cold start at 25 °C EN61000-3-2 Class A 264 VAC, 60 Hz µA W Output Characteristic Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Total Regulation Min. 12 Typ. Max. 24 ±2 Units VDC % 2 150 ±0.5 ±5 s ms ms % % 4 % Ripple and Noise 1.5 % pk-pk Overshoot Overload Protection Overvoltage Protection Short Circuit Protection Thermal Protection Temperature Coefficient Patient Leakage Current 10 175 150 % % % 95 %/°C µA 264 VAC, 60 Hz Maximum +60 Units °C Notes & Conditions Derate from 100% load at 40 °C to 60% load at 60 °C 10/20 Transient Response 115 Trip and restart (hiccup), auto resetting Measured internally, auto resetting 0.02 Notes & Conditions See Models and Ratings table At 50% load No minimum load required Full load and 115/230 VAC Maximum deviation, recovering to less than 1% within 500 µs for 25% step load 20 MHz bandwidth, measured with 20 MHz Bandwidth and 10 µF electrolytic in parallel with 0.1 µF ceramic capacitor. At turn on / turn off Recycle mains to reset Environmental Characteristic Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Vibration Minimum 0 Natural convection 5 -20 Typical 95 %RH +80 °C 5000 m IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes Non-condensing Derating Curve Output Power (%) 100% 80% 60% 40% 20% 0 20 Ambient Temperature (ºC) www.xppower.com 40 60 2 ALM85 Series AC-DC Power Supplies General Characteristic Minimum Efficiency Typical Maximum Notes & Conditions Units % 88 Switching Frequency Power Density Mean Time Between Failure Weight See Models and Ratings table and curves. 4000 VAC 2 x MOPP 1500 VAC 1 x MOPP (Class I versions only) 500 VAC Class I versions only 65 KHz kHz PWM 4.55 W/in3 Isolation: Input to Output Input to Ground Output to Ground >300 kHrs 0.78 (355) lb (g) MIL-HDBK-217F at 25 °C GB Efficiency Curves ALM85US12 100.00% Efficiency 90.00% 80.00% 115V 230V 70.00% 60.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Load ALM85US24 100.00% Efficiency 90.00% 80.00% 115V 230V 70.00% 6 60.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Load EMC: Emissions Phenomenon Emissions Harmonic Current Voltage Flicker Standard EN55022 EN61000-3-2 EN61000-3-3 Test Level Level B Class A www.xppower.com Notes & Conditions Conducted & Radiated 3 ALM85 Series AC-DC Power Supplies EMC: Immunity Phenomenon ESD Radiated EFT/Burst Surge Conducted Magnetic Fields Test Level 3 10 V/m 3 Installation Class 3 10 V 4 Dip: 30% 500 ms Dip: 60% 200 ms Dip: 80% 5000 ms Int: 100% 10 ms Int: 100% 20 ms Int: 100% 5000 ms Dip: 30% 25 AC Cycles Dip: 60% 5 AC Cycles Int: 100% 0.5 AC Cycles Int: 100% 1.0 AC Cycles Int: 100% 250 AC Cycles Standard EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 Dips and Interruptions EN60601-1-2 Criteria A A A A A A A/B A/B B A B B A A A A B Notes & Conditions ±15 kV air/±8 kV contact 80-2700 MHz. IEC60601-1-2 Ed.4 at other frequencies High Line/Low Line High Line/Low Line 230 VAC 100% load, 100 VAC 80% 230 VAC 100% load, 100 VAC 30% 230 VAC 100% load, 100 VAC 50% Safety Approvals Safety Agency Safety Standard UL Notes & Conditions UL60950-1 2nd Edition TUV EN60950-1 CB IEC60950-1 CE LVD UL ANSI/AAMI ES 60601-1 CSA CSA C22.2 No. 60601 TUV EN60601-1 CB IEC60601-1 Information Technology Medical Mechanical Details AC Input IEC 320-C14 -A Versions 5.31 (135.0) 1.58 (40.2) 35.43 ±0.79 (900.0 ±20.0) 1.5 (38.4) AC Input IEC 320-C14 Standard Version 1.46 (37.0) 2.44 (62.0) 1.46 (37.0) 12 & 15 V Versions KPPX-4P K (Non-Locking) ø0.685 (17.4) 1.95 ±0.039 (50.0 ±10.0) 0.17 (4.4) AC Input IEC 320-C8 C2-8 Versions 0.37 ±0.012 (9.5 ±0.3) Pin 1 2 3 4 Connection +Vout +Vout RTN RTN 0.039 (1.0) 1.89 (48.0) 19 & 24 V Versions 4.76 (121.0) 3.04 (77.2) Return (-) 1.46 (37.0) Output (+) 1.58 (40.2) Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 0.78 lbs (355 g) approx. 3. For European mains lead order part EU-MAINS-IEC for C14 versions, or EU-MAINS-8 for C8 versions. 4. For UK mains lead order part UK-MAINS-IEC for C14 versions, or UK-MAINS-8 for C8 versions. 5. For US mains lead order part US-MAINS-IEC for C14 versions, or US-MAINS-8 for C8 versions. 6. Output connector: 12 V & 15 V: 4 pin power din with pin 1 & 2 - posiitive and pin 3 & 4 - return, equivalent to KPPX-4P (non-locking). 19 V & 24 V: DC barrel jack; 5.5 outer diameter, 2.5 mm inner diameter with centre positive. www.xppower.com 29 Aug 17