FILTER2 & FILTER2T ANTI-INTERFERENCE FILTER FEATURES RoHS PRODUCT PROGRAM ● Small Footprint ● Industry Standard Pinout ● UL94-V0 Package ● Low price ● No Heatsink Required Part Number Inductance value (µH) Rated current (A)(max) DCR(Ω) Weight (g) FILTER2 2200*2 0.6 0.25 1.8 FILTER2T 660*2 1.2 0.10 1.2 COMMON SPECIFICATIONS Item Test Conditions Min. Storage humidity 95 -25 105 Storage temperature -55 125 Lead temperature The series applies to analog circuits which Max. Operating temperature APPLICATIONS are more sensitive to noise, and other Typ. FILTER2(1.5mm from case for 10 seconds) 300 FILTER2T(1.5mm from case for 10 seconds) 260 Units % Note: All specifications measured at TA=25°C, humidity<75% unless otherwise specified. occasions. If added a Filter2/Filter2T input to the module, the output noise can be reduced INTERNAL SCHEMATIC substantially. MORNSUN Science & Technology Co.,Ltd. Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China. Tel: 86-20-38601850 Fax:86-20-38601272 APPLICATION CIRCUIT +Vin Http://www.mornsun-power.com DC/DC CONVERTER -Vin OUTLINE DIMENSIONS (Unit: mm) RECOMMENDED FOOTPRINT MECHANICAL DIMMENSIONS FI LTER2T FI LTER2 5 .0 8 [0 .2 00 ] 2 1 2 3 (Front View) 1 2 3 4 4.10 [0.161] Φ1.00[0.039] 10.20 [0.402] (Top View) 4 11.50 [0.453] 1 Note: grid 2.54*2.54mm. TUBE OUTLINE DIMENSIONS 3 9.60 [0.378] 7.62 [0.300] 2. 54 [ 0. 10 0] (Side View) 12 .5 0 [ 0. 49 2 ] 7.50 [0.295] 9 .4 0 [ 0. 37 0 ] 0 .2 5 [0 .0 10 ] 0.50 [0.020] 1.25 [0.492] (Front View) ( Bottom View ) 12.40 [0.488] 2.54 [0.100] 0.30 [0.012] 5.90 [0.232 ] 8 .7 0 [0 .3 43 ] 16.90[0.665] 4 4.90[0.193] Note: Unit: mm[inch] General tolerance ±0.50mm[±0.020inch] L=530mm[20.866 inch] Packaging quantity:43pcs L=220mm[8.661inch] Packaging quantity:17 pcs Short tube inner packaging dimensions: L*W*H=255*170*80mm; Short tube outer packaging dimensions (with six inner packaging boxes): L*W*H=375*280*270mm; Long tube inner packaging dimensions: L*W*H=580*200*100mm; Long tube outer packaging dimensions(with two inner packaging boxes) : L*W*H=600*215*220mm; Long tube outer packaging dimensions(with three inner packaging boxes) : L*W*H=600*215*325mm. The copyright and authority for the interpretation of the products are reserved by MORNSUN Specifications subject to change without notice. FILTER2 & FILTER2T A/2-2012 Page 1 of 1 °C