MCC MP406W 40 amp single phase bridge rectifier 50 to 1000 volt Datasheet

MCC
MP4005W
TM
Micro Commercial Components
omponents
20736 Marilla Street Chatsworth
!"#
$ % !"#
Features
•
•
•
•
THRU
MP4010W
40 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
Mounting Hole For #8 Screw
Plastic Case with Metal Bottom
Any Mounting Position
Surge Rating Of 400 Amps
Maximum Ratings
•
•
MP-50W
Operating Temperature: -50°C to +150°C
Storage Temperature: -50°C to +150°C
MCC
Catalog
Number
Device
Marking
Maximum
Recurrent
Peak Reverse
Voltage
MP4005W MP4005W
50V
MP401W MP401W
100V
MP402W MP402W
200V
MP404W MP404W
400V
MP406W MP406W
600V
MP408W MP408W
800V
MP4010W MP4010W
1000V
B
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
C
E
D
IG
AC
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element
IF(AV)
40.0A
TJ = 55°C
IFSM
400A
8.3ms, half sine
+
D
A
H
AC
-
I
A
VF
1.2V
IFM = 20A per
element;
TJ = 25°C*
Maximum DC
Reverse Current At
IR
10µA
TJ = 25°C
Rated DC Blocking
1.0mA TJ = 100°C
Voltage
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
DIMENSIONS
DIM
A
B
C
D
E
G
H
i
INCHES
MIN
1.118
.432
.769
.673
.038
.193
.429
.169
MAX
1.130
.442
--.752
.042
--.468
.236
MM
MIN
28.40
10.97
19.53
17.10
.97
4.90
10.90
4.30
MAX
28.70
11.23
--19.10
1.07
--11.90
6.00
NOTE
4PL/TYP
∅
www.mccsemi.com
Revision: 5
2004/06/21
MCC
MP4005W thru MP4010W
Figure 1
Typical Forward Characteristics
Micro Commercial Components
Figure 2
Typical Reverse Characteristics
100
10
60
6
40
4
20
2
.6
6
.4
4
.2
2
25°C
µAmps .1
1
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.00
4
.04
.002
.02
.01
TJ=25°C
1
10
Amps
TM
.001
20
.2
.4
.6
.8
1.0
1.2
40
60
80
100
120
140
1.4
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
60
600
50
500
40
400
300
30
Amps
Amps
200
20
100
10
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
25
50
75
100
0
150
1
2
4
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
8 10
20
40
00
60 80 100
Cycles
175
°C
6
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
Revision: 5
2004/06/21