Through Hole Lamp Product Data Sheet LTL42NKRKNN Spec No.: DS20-2001-042 Effective Date: 05/20/2015 Revision: C LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien 1 Road, Chung Ho, New Taipei City 23585, Taiwan, R.O.C. Tel: 886-2-2222-6181 Fax: 886-2-2221-1948 / 886-2-2221-0660 http://www.liteon.com/opto Through Hole Lamp LTL42NKRKNN Through Hole Lamp LTL42NKRKNN Rev Description By Date Above data for PD and Customer tracking only - NPPR Receive and Upload on OPNC MH Lee 10/23/2002 A P7~P10 ADD PRECAUTION MH Lee 07/31/2003 B P5: CHANGE THE BAG LABLE(BARCODE LABEL) MH Lee 08/15/2003 C Update DS Jeromy 05/18/2015 1/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4 Through Hole Lamp LTL42NKRKNN 1. Description Through hole LEDs are offered in a variety of packages such as 3mm, 4mm, 5mm, rectangular, and cylinder which are suitable for all applications requiring status indication. Several intensity and viewing angle choices are available in each color for design flexibility. 1. 1. Features Lead free & RoHS Compliant High luminous intensity output. Low power consumption. High efficiency. Versatile mounting on P.C. Board or panel. I.C. Compatible/low current requirement. AlInGaP Super Red Lamp & Water Clear Lens. 1.2. Applications Communication Computer Consumer Home appliance Industrial 2. Outline Dimensions Notes : 1. 2. 3. 4. 5. All dimensions are in millimeters (inches). Tolerance is ±0.25mm (.010") unless otherwise noted. Protruded resin under flange is 1.0mm (.04") max. Lead spacing is measured where the leads emerge from the package. Specifications are subject to change without notice. 2/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4 Through Hole Lamp LTL42NKRKNN 3. Absolute Maximum Ratings at TA=25°C Parameter Maximum Rating Unit 75 mW (1/10 Duty Cycle, 0.1ms Pulse Width) 90 mA DC Forward Current 30 mA Derating Linear From 50°C 0.4 mA/°C Power Dissipation Peak Forward Current Operating Temperature Range -40°C to + 100°C Storage Temperature Range -55°C to + 100°C Lead Soldering Temperature [2.0mm(.0787") From Body] 260°C for 5 Seconds Max. 4. Electrical / Optical Characteristics at TA=25°C Parameter Symbol Min. Typ. IV 110 180 Max. Unit Test Condition IF = 20mA Luminous Intensity mcd Note 1 Viewing Angle Peak Emission Wavelength 2θ1/2 56 deg λP 639 nm Note 2 (Fig.6) Measurement @Peak (Fig.1) Dominant Wavelength λd 631 nm Spectral Line Half-Width Δλ 20 nm Forward Voltage VF 2.0 Reverse Current IR Note 4 2.4 V IF = 20mA 100 μA VR = 5V,Note 6 NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE eye-response curve. 2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity. 3. Iv classification code is marked on each packing bag. 4. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color of the device. 5. Iv guarantee must be included with ±15% testing tolerance. 6. Reverse voltage (VR) condition is applied for IR test only. The device is not designed for reverse operation. 3/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4 Through Hole Lamp LTL42NKRKNN 5. Typical Electrical / Optical Characteristics Curves (25°C Ambient Temperature Unless Otherwise Noted) 4/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4 Through Hole Lamp LTL42NKRKNN 6. Packing Spec. 1000, 500 or 200,100 pcs per packing bag 10 packing bags per Inner carton Total 10,000 pcs per Inner carton 8 inner cartons per outer carton Total 80,000 pcs per outer carton In every shipping lot, only the last pack will be non-full packing 5/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4 Through Hole Lamp LTL42NKRKNN 7. Bin Table Specification Luminous Intensity Unit : mcd @20mA Bin Code Min. Max. F 110 140 G 140 180 H 180 240 J 240 310 K 310 400 L 400 520 Note: Tolerance of each bin limit is ±15% Dominant Wavelength Unit : nm @20mA Bin Code Min Max H29 621.0 625.0 H30 625.0 629.0 H31 629.0 633.0 H32 633.0 637.0 H33 637.0 642.0 Note: Tolerance of each bin limit is ±1nm 6/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4 Through Hole Lamp LTL42NKRKNN 8. CAUTIONS 8.1. Application This LED lamp is good for application of indoor and outdoor sign, also ordinary electronic equipment. 8.2. Storage The storage ambient for the LEDs should not exceed 30°C temperature or 70% relative humidity. It is recommended that LEDs out of their original packaging are used within three months. For extended storage out of their original packaging, it is recommended that the LEDs be stored in a sealed container with appropriate desiccant or in desiccators with nitrogen ambient. 8.3. Cleaning Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LEDs if necessary. 8.4. Lead Forming & Assembly During lead forming, the leads should be bent at a point at least 3mm from the base of LED lens. Do not use the base of the lead frame as a fulcrum during forming. Lead forming must be done before soldering, at normal temperature. During assembly on PCB, use minimum clinch force possible to avoid excessive mechanical stress. 8.5. Soldering When soldering, leave a minimum of 2mm clearance from the base of the lens to the soldering point. Dipping the lens into the solder must be avoided. Do not apply any external stress to the lead frame during soldering while the LED is at high temperature. Recommended soldering conditions: Soldering iron Temperature Soldering time Position 350°C Max. 3 seconds Max. (one time only) No closer than 2mm from the base of the epoxy bulb Wave soldering Pre-heat Pre-heat time Solder wave Soldering time Dipping Position 100°C Max. 60 seconds Max. 260°C Max. 5 seconds Max. No lower than 2mm from the base of the epoxy bulb Note: Excessive soldering temperature and/or time might result in deformation of the LED lens or catastrophic failure of the LED. IR reflow is not suitable process for through hole type LED lamp product. 8.6. Drive Method An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs connected in parallel in an application, it is recommended that a current limiting resistor be incorporated in the drive circuit, in series with each LED as shown in Circuit A below. Circuit model (A) LED Circuit model (B) LED (A) Recommended circuit (B) The brightness of each LED might appear different due to the differences in the I-V characteristics of those LEDs. 7/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4 Through Hole Lamp LTL42NKRKNN 8.7. ESD (Electrostatic Discharge) Static Electricity or power surge will damage the LED. Suggestions to prevent ESD damage: Use a conductive wrist band or anti- electrostatic glove when handling these LEDs All devices, equipment, and machinery must be properly grounded Work tables, storage racks, etc. should be properly grounded Use ion blower to neutralize the static charge which might have built up on surface of the LEDs plastic lens as a result of friction between LEDs during storage and handing Suggested checking list: Training and Certification 8.7.1.1. Everyone working in a static-safe area is ESD-certified? 8.7.1.2. Training records kept and re-certification dates monitored? Static-Safe Workstation & Work Areas 8.7.2.1. Static-safe workstation or work-areas have ESD signs? 8.7.2.2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V? 8.7.2.3. All ionizer activated, positioned towards the units? 8.7.2.4. Each work surface mats grounding is good? Personnel Grounding 8.7.3.1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or conductive shoes with conductive flooring? 8.7.3.2. If conductive footwear used, conductive flooring also present where operator stand or walk? 8.7.3.3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*? 8.7.3.4. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs? 8.7.3.5. All wrist strap or heel strap checkers calibration up to date? Note: *50V for Blue LED. Device Handling 8.7.4.1. Every ESDS items identified by EIA-471 labels on item or packaging? 8.7.4.2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe workstation? 8.7.4.3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items? 8.7.4.4. All flexible conductive and dissipative package materials inspected before reuse or recycle? Others 8.7.5.1. Audit result reported to entity ESD control coordinator? 8.7.5.2. Corrective action from previous audits completed? 8.7.5.3. Are audit records complete and on file? 8/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4 Through Hole Lamp LTL42NKRKNN 9. Reliability Test Classification Endurance Test Item Test Condition Sample Size Reference Standard Operation Life Ta = Under room temperature IF = per datasheet maximum drive current Test Time= 1000hrs 22 PCS (CL=90%; LTPD=10%) High Temperature High Humidity storage Ta = 60°C RH = 90% Test Time= 240hrs 22 PCS (CL=90%; LTPD=10%) High Temperature Storage Ta= 105 ± 5°C Test Time= 1000hrs 22 PCS (CL=90%; LTPD=10%) MIL-STD-750D:1031 (1995) MIL-STD-883G:1008 (2006) JEITA ED-4701:200 201 (2001) Low Temperature Storage Ta= -55 ± 5°C Test Time= 1000hrs 22 PCS (CL=90%; LTPD=10%) JEITA ED-4701:200 202 (2001) Temperature Cycling 100°C ~ 25°C ~ -40°C ~ 25°C 22 PCS 30mins 5mins 30mins 5mins (CL=90%; LTPD=10%) 30 Cycles MIL-STD-750D:1051 (1995) MIL-STD-883G:1010 (2006) JEITA ED-4701:100 105 (2001) JESD22-A104C (2005) Thermal Shock 100 ± 5°C ~ -30°C ± 5°C 15mins 15mins 30 Cycles (<20 secs transfer) 22 PCS (CL=90%; LTPD=10%) MIL-STD-750D:1056 (1995) MIL-STD-883G:1011 (2006) MIL-STD-202G:107G (2002) JESD22-A106B (2004) Solder Resistance T.sol = 260 ± 5°C Dwell Time= 10±1 seconds 3mm from the base of the epoxy bulb 11 PCS (CL=90%; LTPD=18.9%) MIL-STD-750D:2031(1995) JEITA ED-4701: 300 302 (2001) Solderability T. sol = 245 ± 5°C 11 PCS Dwell Time= 5 ± 0.5 seconds (CL=90%; (Lead Free Solder, Coverage ≧95% of LTPD=18.9%) the dipped surface) MIL-STD-750D:1026 (1995) MIL-STD-883G:1005 (2006) MIL-STD-202G:103B (2002) JEITA ED-4701:100 103 (2001) Test Environmental Test Soldering Iron T. sol = 350 ± 5°C Dwell Time= 3.5 ± 0.5 seconds 11 PCS (CL=90%; LTPD=18.9%) MIL-STD-750D:2026 (1995) MIL-STD-883G:2003 (2006) MIL-STD-202G:208H (2002) IPC/EIA J-STD-002 (2004) MIL-STD-202G:208H (2002) JEITA ED-4701:300 302 (2001) 10. Others The appearance and specifications of the product may be modified for improvement, without prior notice. 9/9 Part No. : LTL42NKRKNN BNS-OD-FC002/A4