Qualtek FDA2-17251QBKT3F-L 172x150x51mm ac axial fan Datasheet

AC AXIAL FAN
172x150x51mm
FDA2-17251 Series
Features:
Motor: External Rotor Capacitor-Run Induction Motor
Motor Protection: Thermal Protected
Bearing Type: Two Ball
Connection: UL 1015 AWG 22, 300mm Wire Leads or Terminal
Frame Material: Aluminum Alloy
Impeller Material: Plastic UL94V-0, or Steel
Operating Temp:
Two Ball: -20°C~70°C
Life Expectancy:
Two Ball: 50,000 Hours
Two Ball: 100,000 Hours (-L)
Fan-S Division
Volt.
Model No.
Freq.
Current
Power
(A)
(W)
Rated
Speed
Maximum
AirFlow
Maximum Static
Pressure
(InAq)
(mmAq)
Noise
Level
Weight
(CMM)
(CFM)
(dB/A)
(g)
115
50/60
0.22/0.24 24.0/27.0
2800/3300 6.51/7.78
230/275
0.649/0.768 16.5/19.5
54.0/60.0
890
FDA2-17251QBK * 3F # 230
FDA2-17251NBH * ** F # 115
50/60
0.11/0.12 24.0/27.0
2800/3300 6.51/7.78
230/275
0.649/0.768 16.5/19.5
54.0/60.0
890
50/60
0.25/0.21 27.0/25.0
2700/3100 5.95/7.08
210/250
0.551/0.610 14.0/15.5
53.0/59.0
940
(VAC)
FDA2-17251NBK * 3F
#
(Hz)
(rpm)
#
50/60 0.11/0.12 26.0/27.0
53.0/59.0 940
210/250 0.551/0.610 14.0/15.5
2700/3100 5.95/7.08
FDA2-17251QBH * ** F 230
* Indicates “W” (Wire Leads) or “T” (Terminal)
Noise is measured at the distance of one (1) meter from the axis of intake.
** Indicates “3” (Metal Frame, Plastic Impeller) or “4” (Metal Frame and Impeller)
# Indicates “-L” (100,000 Hours Life Expectancy) or Leave Blank (50,000 Hours Life Expectancy)
Fan Performance Curve
20
12
55.5˚
8
4
151 ± 1
STATIC PRESSURE (mmAq)
K
16
Ø4.3 ± 0.2
0
0
50
100
150
200
250
M4xP0.7
FLOWRATE (CFM)
Fan Performance Curve
20
H
STATIC PRESSURE (mmAq)
R otation direction
Air flow
H
K
16
3
12
51.0 ± 0.5
162 ± 0.3
172 ± 0.5
8
4
0
0
50
100
150
200
FLOWRATE (CFM)
ISO-9001 Company
250
300
Qualtek
Electronics Corporation