Features
•
•
•
•
High Surge Capability
Low Forward Voltage Drop
High Current Capability
Super Fast Switching Speed For High Efficiency
1 Amp Super Fast
Recovery Rectifier
50 to 1000 Volts
Maximum Ratings
•
•
Operating Temperature: -50°C to +150°C
Storage Temperature: -50°C to +150°C
MCC
Part Number
MUR105
MUR110
MUR115
MUR120
MUR140
MUR160
MUR180
MUR1100
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
150V
200V
400V
600V
800V
1000V
Maximum
RMS Voltage
35V
70V
105V
140V
280V
420V
560V
700V
DO-41
Maximum DC
Blocking
Voltage
50V
100V
150V
200V
400V
600V
800V
1000V
D
Electrical Characteristics @ 25° C Unless Otherwise Specified
Average Forward
IF(AV)
1A
TA = 55°C
Current
Peak Forward Surge
IFSM
35A
8.3ms, half sine
Current
Maximum
Instantaneous
Forward Voltage
IFM = 1.0A;
VF
.975V
MUR105-115
1.35V
MUR120-160
TA = 25°C
1.75V
MUR180-1100
Maximum DC
IR
Reverse Current At
5µA
TA = 25°C
Rated DC Blocking
50µA
TA = 150°C
Voltage
Maximum Reverse
Recovery Time
MUR105-120
Trr
45ns
IF=0.5A, IR=1.0A,
MUR140-160
60ns
Irr=0.25A
MUR180-1100
75ns
Measured at
Typical Junction
20pF
CJ
1.0MHz, VR=4.0V
Capacitance
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
A
Cathode
Mark
B
D
C
DIMENSIONS
DIM
A
B
C
D
INCHES
MIN
.166
.080
.028
1.000
MAX
.205
.107
.034
---
www.mccsemi.com
MM
MIN
4.10
2.00
.70
25.40
MAX
5.20
2.70
.90
---
NOTE
MCC
MUR105 thru MUR1100
Figure 1
Typical Forward Characteristics
20
Figure 2
Forward Derating Curve
10
1.5
6
4
1.25
2
25°C
Amps
1.0
1
.6
.75
MUR180-1100
.4
Amps
MUR105-115
.5
.2
MUR120-160
.25
.1
.06
0
.04
25
50
75
100
125
175
.5
.7
.9
1.1
1.3
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
1.5
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
100
60
40
20
pF
150
°C
.02
.01
Single Phase, Half Wave
60Hz Resistive or Inductive Load
TJ=25°C
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100 200
400
Junction Capacitance - pF versus
Reverse Voltage - Volts
www.mccsemi.com
1000
MCC
MUR105 thru MUR110
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
100
60
60
40
20
50
TA =150 °C
40
10
30
6
Amps
4
20
10
2 TA=100 °C
0
µAmps 1
1
4
2
6 8 10 20
40
60 80 100
.6
Cycles
.4
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
.2
.1 TA =25°C
.06
.04
.02
.01
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
50Ω
10Ω
trr
+0.5A
0
Pulse
Generator
Note 2
25Vdc
1Ω
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive