Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch PART NUMBER DESCRIPTION CCR-38S Commercial Normally Open Multi-throw, DC-18GHz CR-38S Elite Normally Open Multi-throw, DC-22GHz The CCR-38S/CR-38S is a broadband, multi-throw, electromechanical coaxial switch designed to switch a microwave signal from a common input to any of 3, 4, 5, or 6 outputs. The characteristic impedance is 50 Ohms. The switches are small using the popular connector spacing on a 1.062” dia. circle. Each position has an individual actuator mechanism allowing random position selection. This also gives the minimum switching time. With the normally open actuator, all paths are open when the switch is de-energized. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS Operating Temperature Commercial Model, CCR-38S Elite Model, CR-38S Form Factor –40°C to 65°C –55°C to 85°C Multi-Throw, break before make Vibration (MIL-STD-202 Method 214, Condition D, non-operating) 10 g’s RMS Frequency Range CCR-38S CR-38S DC–18 GHz DC-22 GHz Shock (MIL-STD-202 Method 213, Condition D, non-operating) 500 g’s Characteristic Impedance 50 Ohms Standard Actuator Life Actuator Life w/ Additional Features 5,000,000 cycles 1,000,000 cycles Connector Type SMA Humidity (Moisture Seal) Available Weight 6 oz. (170.1g) (max.) Operate Time 15 ms (max.) Release Time 15 ms (max.) Actuation Voltage Available 12 Actuation Current, max. @ ambient 400 205 170 140 mA 15 24 28 V PERFORMANCE CHARACTERISTICS Frequency DC–4 GHz 4–8 GHz 8–12 GHz 12–16 GHz 16-20 GHz 20-22 GHz Insertion Loss, dB, max. 0.1 0.2 0.2 0.3 0.3 0.4 Isolation, dB, min. 80 80 80 80 75 70 1.05:1 1.1:1 1.2:1 1.2:1 1.2:1 1.2:1 VSWR , max. PART NUMBERING SYSTEM CCR-38 S 1 6 C - T ** Series Options Connectors Actuator Type Actuator Voltage Number of Positions CONNECTOR ACTUATOR VOLTAGE NUMBER OF POSITIONS ACTUATOR TYPE OPTIONS S: SMA FEMALE 1: 28 VDC NORMALLY OPEN 3: SP3T 0: NO INDICATOR CONTACTS T: TTL DRIVERS WITH DIODES 2: 15 VDC NORMALLY OPEN 4: SP4T C: INDICATOR CONTACTS D: COIL TRANSIENT SUPPRESSION DIODES 3: 12 VDC NORMALLY OPEN 5: SP5T S: D-SUB CONNECTOR* 4: 24 VDC NORMALLY OPEN 6: SP6T TD: DECODERS AND TTL DRIVERS WITH DIODES **SEE PARTS LIST ON PAGE 12-13 For additional options, please contact factory. © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com M: MOISTURE SEAL * D-Sub Connector may be 9 or 15 pin depending on number of throws. (See Connector Pinout page) CCR-38S/CR-38S Page 1 CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch SCHEMATICS AND MECHANICAL OUTLINE Analog Indicators TTL SP3T SP4T SP5T H = 1.75 STD & Indicator Model H = 2.00 D-Sub Model H = 2.25 Indicator with D-Sub Model H = 2.50 TTL, TTL with Indicators & TTL with D-Sub Model SP6T “-S OPTION” 9-PIN D-SUB OR 15-PIN D-MICRO CONNECTOR (EXAMPLE: CCR-38S/CR-38S Page 2 CCR-38S160-S) SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch CONNECTOR PINOUT FOR NORMALLY OPEN SP3T MULTI-THROW SWITCHES EXAMPLE CR-38S130-S CR-38S13C-S INDICATOR CR-38S130-TS YES CR-38S13C-TS CR-38S130-TDS YES TTL YES YES CR-38S13C-TDS YES DECODERS & TTL YES YES 9-PIN 9-PIN 9-PIN 9-PIN 9-PIN 9-PIN 1 PORT 1 PORT 1 PORT 1 PORT 1 LOGIC 1 LOGIC 1 2 PORT 2 PORT 2 PORT 2 PORT 2 LOGIC 2 LOGIC 2 3 PORT 3 PORT 3 PORT 3 PORT 3 PIN NO. 4 E INDICATOR E INDICATOR 5 F INDICATOR F INDICATOR F INDICATOR 6 G INDICATOR G INDICATOR G INDICATOR 7 COMMON COMMON COMMON 8 VSW 9 D INDICATOR (COM) E INDICATOR COMMON COMMON VSW VSW D INDICATOR (COM) COMMON VSW D INDICATOR (COM) CONNECTOR PINOUT FOR NORMALLY OPEN SP4T MULTI-THROW SWITCHES EXAMPLE CR-38S140-S CR-38S14C-S CR-38S140-TS YES INDICATOR TTL CR-38S14C-TS CR-38S140-TDS YES YES YES CR-38S14C-TDS YES DECODERS & TTL YES YES 9-PIN 15-PIN 9-PIN 15-PIN 9-PIN 15-PIN 1 PORT 1 PORT 1 TTL 1 TTL 1 LOGIC 1 LOGIC 1 2 PORT 2 PORT 2 TTL 2 TTL 2 LOGIC 2 LOGIC 2 3 PORT 3 PORT 3 TTL 3 TTL 3 LOGIC 3 LOGIC 3 4 PORT 4 PORT 4 TTL 4 TTL 4 COMMON COMMON COMMON COMMON COMMON COMMON VSW VSW VSW PIN NO. 5 6 7 8 VSW 9 D INDICATOR (COM) D INDICATOR (COM) D INDICATOR (COM) 10 E INDICATOR E INDICATOR E INDICATOR 11 F INDICATOR F INDICATOR F INDICATOR 12 G INDICATOR G INDICATOR G INDICATOR N/A N/A 13 H INDICATOR N/A H INDICATOR H INDICATOR 14 15 1 6 15-PIN D-MICRO CONNECTOR 9-PIN D-SUB CONNECTOR © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-38S/CR-38S Page 3 CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch CONNECTOR PINOUT FOR NORMALLY OPEN SP5T MULTI-THROW SWITCHES EXAMPLE CR-38S150-S CR-38S15C-S CR-38S150-TS YES INDICATOR TTL CR-38S15C-TS CR-38S150-TDS YES YES YES CR-38S15C-TDS YES DECODERS & TTL YES YES 9-PIN 15-PIN 9-PIN 15-PIN 9-PIN 15-PIN 1 PORT 1 PORT 1 TTL 1 TTL 1 LOGIC 1 LOGIC 1 2 PORT 2 PORT 2 TTL 2 TTL 2 LOGIC 2 LOGIC 2 3 PORT 3 PORT 3 TTL 3 TTL 3 LOGIC 3 LOGIC 3 4 PORT 4 PORT 4 TTL 4 TTL 4 5 PORT 5 PORT 5 TTL 5 TTL 5 COMMON COMMON COMMON COMMON COMMON COMMON VSW VSW VSW PIN NO. 6 7 8 VSW 9 D INDICATOR (COM) D INDICATOR (COM) D INDICATOR (COM) 10 E INDICATOR E INDICATOR E INDICATOR 11 F INDICATOR F INDICATOR F INDICATOR 12 G INDICATOR G INDICATOR G INDICATOR N/A N/A N/A 13 H INDICATOR H INDICATOR H INDICATOR 14 K INDICATOR K INDICATOR K INDICATOR 15 CONNECTOR PINOUT FOR NORMALLY OPEN SP6T MULTI-THROW SWITCHES EXAMPLE CR-38S160-S CR-38S16C-S CR-38S160-TS YES INDICATOR TTL CR-38S16C-TS CR-38S160-TDS YES YES YES DECODERS & TTL CR-38S16C-TDS YES YES YES 9-PIN 15-PIN 9-PIN 15-PIN 9-PIN 15-PIN 1 PORT 1 PORT 1 TTL 1 TTL 1 LOGIC 1 LOGIC 1 2 PORT 2 PORT 2 TTL 2 TTL 2 LOGIC 2 LOGIC 2 3 PORT 3 PORT 3 TTL 3 TTL 3 LOGIC 3 LOGIC 3 4 PORT 4 PORT 4 TTL 4 TTL 4 5 PORT 5 PORT 5 TTL 5 TTL 5 6 PORT 6 PORT 6 TTL 6 TTL 6 7 COMMON COMMON COMMON COMMON COMMON COMMON VSW VSW VSW PIN NO. 8 VSW 9 D INDICATOR (COM) D INDICATOR (COM) D INDICATOR (COM) 10 E INDICATOR E INDICATOR E INDICATOR 11 F INDICATOR F INDICATOR F INDICATOR 12 G INDICATOR G INDICATOR G INDICATOR N/A N/A N/A 13 H INDICATOR H INDICATOR H INDICATOR 14 K INDICATOR K INDICATOR K INDICATOR 15 L INDICATOR L INDICATOR L INDICATOR CCR-38S/CR-38S Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch TRUTH TABLE Normally Open CCR-38SX3C-T Logic Input 1 2 RF Path 3 J1 J2 Indicator Switches J3 E F G 1 0 0 On Off Off C 0 0 0 1 0 Off On Off 0 C 0 0 0 1 Off Off On 0 0 C TRUTH TABLE Normally Open CCR-38SX3C-TD Logic Input 1 RF Path 2 J1 J2 Indicator Switches J3 E F G 0 0 On Off Off C 0 0 1 0 Off On Off 0 C 0 0 1 Off Off On 0 0 C 1 1 Off Off Off 0 0 0 TRUTH TABLE Normally Open CCR-38SX4C-T Logic Input RF Path Indicator Switches 1 2 3 4 J1 J2 J3 J4 E F G H 1 0 0 0 On Off Off Off C 0 0 0 0 1 0 0 Off On Off Off 0 C 0 0 0 0 1 0 Off Off On Off 0 0 C 0 0 0 0 1 Off Off Off On 0 0 0 C TRUTH TABLE Normally Open CCR-38SX4C-TD Logic Input RF Path Indicator Switches 1 2 3 J1 J2 J3 J4 E F G H 0 0 0 On Off Off Off C 0 0 0 1 0 0 Off On Off Off 0 C 0 0 0 1 0 Off Off On Off 0 0 C 0 1 1 0 Off Off Off On 0 0 0 C 1 1 1 Off Off Off Off 0 0 0 0 © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-38S/CR-38S Page 5 CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch TRUTH TABLE Normally Open CCR-38SX5C-T Logic Input RF Path Indicator Switches 1 2 3 4 5 J1 J2 J3 J4 J5 E F G H K 1 0 0 0 0 On Off Off Off Off C 0 0 0 0 0 1 0 0 0 Off On Off Off Off 0 C 0 0 0 0 0 1 0 0 Off Off On Off Off 0 0 C 0 0 0 0 0 1 0 Off Off Off On Off 0 0 0 C 0 0 0 0 0 1 Off Off Off Off On 0 0 0 0 C TRUTH TABLE Normally Open CCR-38SX5C-TD Logic Input RF Path Indicator Switches 1 2 3 J1 J2 J3 J4 J5 E F G H K 0 0 0 On Off Off Off Off C 0 0 0 0 1 0 0 Off On Off Off Off 0 C 0 0 0 0 1 0 Off Off On Off Off 0 0 C 0 0 1 1 0 Off Off Off On Off 0 0 0 C 0 0 0 1 Off Off Off Off On 0 0 0 0 C 1 1 1 Off Off Off Off Off 0 0 0 0 0 TRUTH TABLE Normally Open CCR-38SX6C-T Logic Input RF Path 1 2 3 4 5 6 1 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 Off 0 0 0 1 0 0 Off 0 0 0 0 1 0 Off 0 0 0 0 0 1 Off J3 J4 Indicator Switches J1 J2 J5 J6 E F G H K L 0 On Off Off Off 0 Off On Off Off Off Off Off Off C 0 0 0 0 0 0 C 0 0 0 0 Off On Off Off Off Off Off On Off Off 0 0 C 0 0 0 0 0 0 C 0 0 Off Off Off On Off 0 0 Off Off Off Off On 0 0 0 0 C 0 0 0 0 C TRUTH TABLE Normally Open CCR-38SX6C-TD Logic Input RF Path Indicator Switches 1 2 3 J1 J2 J3 J4 J5 J6 E F G H K L 0 0 0 On Off Off Off Off Off C 0 0 0 0 0 1 0 0 Off On Off Off Off Off 0 C 0 0 0 0 0 1 0 Off Off On Off Off Off 0 0 C 0 0 0 1 1 0 Off Off Off On Off Off 0 0 0 C 0 0 0 0 1 Off Off Off Off On Off 0 0 0 0 C 0 1 0 1 Off Off Off Off Off On 0 0 0 0 0 C 1 1 1 Off Off Off Off Off Off 0 0 0 0 0 0 CCR-38S/CR-38S Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES Insertion Loss ( 4-8 GHz ) 0 0 -0.1 -0.1 Insertion Loss (dB) Insertion Loss (dB) Insertion Loss ( DC-4 GHz ) -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1 -1 0 1 2 3 4 4 5 Frequency (GHz) Insertion Loss ( 8-12 GHz ) 7 8 15 16 Insertion Loss ( 12-16 GHz ) 0 0 -0.1 -0.1 -0.2 -0.2 Insertion Loss (dB) Insertion Loss (dB) 6 Frequency (GHz) -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1 -1 8 9 10 11 12 12 13 Frequency (GHz) 14 Frequency (GHz) Insertion Loss ( 16-20 GHz ) Insertion Loss ( 20-22 GHz ) 0 0 -0.1 -0.2 -0.2 -0.3 Insertion Loss (dB) Insertion Loss(dB) -0.1 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1 16 17 18 Frequency (GHz) 19 20 -1 20 20.5 21 21.5 22 Frequency (GHz) 18GHZ+ ELITE MODEL ONLY RF NOTES © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-38S/CR-38S Page 7 CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES Isolation ( 4-8 GHz ) 0 0 -20 -20 -40 -40 Isolation (dB) Isolation (dB) Isolation ( DC-4 GHz ) -60 -80 -100 -120 -60 -80 -100 -120 -140 -140 0 1 2 3 4 4 5 6 Frequency (GHz) Isolation ( 8-12 GHz ) 8 15 16 Isolation ( 12-16 GHz ) 0 0 -20 -20 -40 -40 Isolation (dB) Isolation (dB) 7 Frequency (GHz) -60 -80 -100 -120 -60 -80 -100 -120 -140 -140 8 9 10 11 12 12 13 14 Frequency (GHz) Frequency (GHz) Isolation ( 16-20 GHz ) Isolation ( 20-22 GHz ) 0 0 -20 -40 Isolation (dB) Isolation (dB) -20 -60 -80 -100 -40 -60 -80 -100 -120 -120 -140 16 17 18 19 Frequency (GHz) 20 -140 20 20.5 21 21.5 22 Frequency (GHz) 18GHZ+ ELITE MODEL ONLY RF NOTES CCR-38S/CR-38S Page 8 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES VSWR ( 4-8 GHz ) 2 2 1.9 1.9 1.8 1.8 1.7 1.7 1.6 1.6 VSWR VSWR VSWR ( DC-4 GHz ) 1.5 1.4 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.1 1 1 0 1 2 3 4 4 5 Frequency (GHz) VSWR ( 8-12 GHz ) 7 8 15 16 VSWR ( 12-16 GHz ) 2 2 1.9 1.9 1.8 1.8 1.7 1.7 1.6 1.6 VSWR VSWR 6 Frequency (GHz) 1.5 1.4 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.1 1 1 8 9 10 11 12 12 13 Frequency (GHz) 14 Frequency (GHz) VSWR ( 16-20 GHz ) VSWR ( 20-22 GHz ) 2 2 1.9 1.9 1.8 1.7 1.7 1.6 1.6 VSWR VSWR 1.8 1.5 1.4 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.1 1 16 17 18 Frequency (GHz) 19 20 1 20 20.5 21 21.5 22 Frequency (GHz) 18GHZ+ ELITE MODEL ONLY RF NOTES © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-38S/CR-38S Page 9 CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch TYPICAL POWER PERFORMANCE CURVE Power Handling vs. Frequency 3000 2000 Power (W) 1000 800 600 400 STAN DAR DS 300 MA 200 SW ITC HES 100 80 60 40 30 20 10 .1 .2 .3 .4 .6 .8 1 2 4 6 8 10 18 Frequency GHz Estimates based on the following reference conditions: • Ambient temperature of 40°C or less • Sea level operation • Load VSWR of 1.20:1 maximum • No high-power (hot) switching Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions. CCR-38S/CR-38S Page 10 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch GLOSSARY Actuator An actuator is the electromechanical mechanism that transfers the RF contacts from one position to another upon DC command. Arc Suppression Diode A diode is connected in parallel with the coil. This diode limits the “reverse EMF spike” generated when the coil deenergizes to 0.7 volts. The diode cathode is connected to the positive side of the coil and the anode is connected to the negative side. Date Code All switches are marked with either a unique serial number or a date code. Date codes are in accordance with MILSTD-1285 Paragraph 5.2.5 and consist of four digits. The first two digits define the year and the last two digits define the week of the year (YYWW). Thus, 1032 identifies switches that passed through final inspection during the 32nd week of 2010. Indicator Indicators tell the system which position the switch is in. Other names for indicators are telemetry contacts or tellback circuit. Indicators are usually a set of internally mounted DC contacts linked to the actuator. They can be wired to digital input lines, status lights, or interlocks. Unless otherwise specified, the maximum indicator contact rating is 30 Vdc, 50 mA, or 1.5 Watts into a resistive load. Isolation Isolation is the measure of the power level at the output connector of an unconnected RF channel as referenced to the power at the input connector. It is specified in dB below the input power level. Multi-Throw Switch A multi-throw switch is a switch with one input and three or more output ports. The CCR-38 can switch a microwave signal to any of 2,3,4,5 or 6 output from a single common input. Switching Time Switching time is the total interval beginning with the arrival of the leading edge of the command pulse at the switch DC input and ending with the completion of the switch transfer, including contact bounce. It consists of three parts: (1) inductive delay in the coil, (2) transfer time of the physical movement of the contacts, and (3) the bounce time of the RF contacts. TTL Switch Driver Option As a special option, switch drivers can be provided for both failsafe and latching switches, which are compatible with industry-standard low-power Schottky TTL circuits. TD-Option This option includes a decoder. The 3-bit parallel command is decoded to internally select the appropriate position. See the logic tables. The TD-Option increases the Vsw supply current demand by 50mA max at 28Vdc and +20°C. Performance Parameters vs Frequency Generally speaking, the RF performance of coaxial switches is frequency dependent. With increasing frequency, VSWR and insertion loss increase while isolation decreases. All data sheets specify these three parameters as “worst case” at the highest operating frequency. If the switch is to be used over a narrow frequency band, better performance can be achieved. Actuator Current vs Temperature The resistance of the actuator coil varies as a function of temperature. There is an inverse relationship between the operating temperature of the switch and the actuator drive current. For switches operating at 28 VDC, the approximate actuator drive current at temperature, T, can be calculated using the equation: IT = [1 + .00385 (T-20)] Where: IT = Actuator current at temperature, T IA = Room temperature actuator current – see data sheet T = Temperature of interest in °C Magnetic Sensitivity An electro-mechanical switch can be sensitive to ferrous materials and external magnetic fields. Neighboring ferrous materials should be permitted no closer than 0.5 inches and adjacent external magnetic fields should be limited to a flux density of less than 5 Gauss. SPECIAL FEATURE Switching High-Power or Highly Sensitive Signals Ensure the most linear response with the best galvanically matched contact system in the industry. Extremely low passive intermodulation is standard on all of our switches. Carrier Frequency 1 Carrier Frequency 2 PIM 3rd Order Frequency PIM 5th Order Frequency 870 MHz 893 MHz 847 MHz 824 MHz Multiple Positions © 2013 TELEDYNE RELAYS IA (800) 284-7007 • www.teledynecoax.com 3rd Order Intermodulation 5th Order Intermodulation –96 dBm –115 dBm –139 dBc –158 dBc CCR-38S/CR-38S Page 11 CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch NORMALLY OPEN CCR-38S/CR-38S PART NUMBER LIST PART NO. * PART NO. PART NO. PART NO. 1 CCR-38SX3C 43 CR-38SX30 85 CR-38SX4C 127 CCR-38SX50 2 CCR-38SX3C-D 44 CR-38SX30-D 86 CR-38SX4C-D 128 CCR-38SX50-D 3 CCR-38SX3C-DM 45 CR-38SX30-DM 87 CR-38SX4C-DM 129 CCR-38SX50-DM 4 CCR-38SX3C-M 46 CR-38SX30-M 88 CR-38SX4C-M 130 CCR-38SX50-M 5 CCR-38SX3C-MS 47 CR-38SX30-MS 89 CR-38SX4C-MS 131 CCR-38SX50-MS 6 CCR-38SX3C-S 48 CR-38SX30-S 90 CR-38SX4C-S 132 CCR-38SX50-S 7 CCR-38SX3C-T 49 CR-38SX30-T 91 CR-38SX4C-T 133 CCR-38SX50-T 8 CCR-38SX3C-TD 50 CR-38SX30-TD 92 CR-38SX4C-TD 134 CCR-38SX50-TD 9 CCR-38SX3C-TDM 51 CR-38SX30-TDM 93 CR-38SX4C-TDM 135 CCR-38SX50-TDM 10 CCR-38SX3C-TDMS 52 CR-38SX30-TDMS 94 CR-38SX4C-TDMS 136 CCR-38SX50-TDMS 11 CCR-38SX3C-TDS 53 CR-38SX30-TDS 95 CR-38SX4C-TDS 137 CCR-38SX50-TDS 12 CCR-38SX3C-TM 54 CR-38SX30-TM 96 CR-38SX4C-TM 138 CCR-38SX50-TM 13 CCR-38SX3C-TMS 55 CR-38SX30-TMS 97 CR-38SX4C-TMS 139 CCR-38SX50-TMS 14 CCR-38SX3C-TS 56 CR-38SX30-TS 98 CR-38SX4C-TS 140 CCR-38SX50-TS 15 CCR-38SX30 57 CCR-38SX4C 99 CR-38SX40 141 CR-38SX5C 16 CCR-38SX30-D 58 CCR-38SX4C-D 100 CR-38SX40-D 142 CR-38SX5C-D 17 CCR-38SX30-DM 59 CCR-38SX4C-DM 101 CR-38SX40-DM 143 CR-38SX5C-DM 18 CCR-38SX30-M 60 CCR-38SX4C-M 102 CR-38SX40-M 144 CR-38SX5C-M 19 CCR-38SX30-MS 61 CCR-38SX4C-MS 103 CR-38SX40-MS 145 CR-38SX5C-MS 20 CCR-38SX30-S 62 CCR-38SX4C-S 104 CR-38SX40-S 146 CR-38SX5C-S 21 CCR-38SX30-T 63 CCR-38SX4C-T 105 CR-38SX40-T 147 CR-38SX5C-T 22 CCR-38SX30-TD 64 CCR-38SX4C-TD 106 CR-38SX40-TD 148 CR-38SX5C-TD 23 CCR-38SX30-TDM 65 CCR-38SX4C-TDM 107 CR-38SX40-TDM 149 CR-38SX5C-TDM 24 CCR-38SX30-TDMS 66 CCR-38SX4C-TDMS 108 CR-38SX40-TDMS 150 CR-38SX5C-TDMS 25 CCR-38SX30-TDS 67 CCR-38SX4C-TDS 109 CR-38SX40-TDS 151 CR-38SX5C-TDS 26 CCR-38SX30-TM 68 CCR-38SX4C-TM 110 CR-38SX40-TM 152 CR-38SX5C-TM 27 CCR-38SX30-TMS 69 CCR-38SX4C-TMS 111 CR-38SX40-TMS 153 CR-38SX5C-TMS 28 CCR-38SX30-TS 70 CCR-38SX4C-TS 112 CR-38SX40-TS 154 CR-38SX5C-TS 29 CR-38SX3C 71 CCR-38SX40 113 CCR-38SX5C 155 CR-38SX50 30 CR-38SX3C-D 72 CCR-38SX40-D 114 CCR-38SX5C-D 156 CR-38SX50-D 31 CR-38SX3C-DM 73 CCR-38SX40-DM 115 CCR-38SX5C-DM 157 CR-38SX50-DM 32 CR-38SX3C-M 74 CCR-38SX40-M 116 CCR-38SX5C-M 158 CR-38SX50-M 33 CR-38SX3C-MS 75 CCR-38SX40-MS 117 CCR-38SX5C-MS 159 CR-38SX50-MS 34 CR-38SX3C-S 76 CCR-38SX40-S 118 CCR-38SX5C-S 160 CR-38SX50-S 35 CR-38SX3C-T 77 CCR-38SX40-T 119 CCR-38SX5C-T 161 CR-38SX50-T 36 CR-38SX3C-TD 78 CCR-38SX40-TD 120 CCR-38SX5C-TD 162 CR-38SX50-TD 37 CR-38SX3C-TDM 79 CCR-38SX40-TDM 121 CCR-38SX5C-TDM 163 CR-38SX50-TDM 38 CR-38SX3C-TDMS 80 CCR-38SX40-TDMS 122 CCR-38SX5C-TDMS 164 CR-38SX50-TDMS 39 CR-38SX3C-TDS 81 CCR-38SX40-TDS 123 CCR-38SX5C-TDS 165 CR-38SX50-TDS 40 CR-38SX3C-TM 82 CCR-38SX40-TM 124 CCR-38SX5C-TM 166 CR-38SX50-TM 41 CR-38SX3C-TMS 83 CCR-38SX40-TMS 125 CCR-38SX5C-TMS 167 CR-38SX50-TMS 42 CR-38SX3C-TS 84 CCR-38SX40-TS 126 CCR-38SX5C-TS 168 CR-38SX50-TS X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc) CCR-38S/CR-38S Page 12 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2013 TELEDYNE COAX SWITCHES CCR-38S\CR-38S\072013\Q3 Series CCR-38S/CR-38S COAX SWITCHES Multi-Throw DC–18 GHz/DC-22 GHz Normally Open Coaxial Switch NORMALLY OPEN CCR-38S/CR-38S PART NUMBER LIST PART NO. * PART NO. 169 CCR-38SX6C 211 CR-38SX60 170 CCR-38SX6C-D 212 CR-38SX60-D 171 CCR-38SX6C-DM 213 CR-38SX60-DM 172 CCR-38SX6C-M 214 CR-38SX60-M 173 CCR-38SX6C-MS 215 CR-38SX60-MS 174 CCR-38SX6C-S 216 CR-38SX60-S 175 CCR-38SX6C-T 217 CR-38SX60-T 176 CCR-38SX6C-TD 218 CR-38SX60-TD 177 CCR-38SX6C-TDM 219 CR-38SX60-TDM 178 CCR-38SX6C-TDMS 220 CR-38SX60-TDMS 179 CCR-38SX6C-TDS 221 CR-38SX60-TDS 180 CCR-38SX6C-TM 222 CR-38SX60-TM 181 CCR-38SX6C-TMS 223 CR-38SX60-TMS 182 CCR-38SX6C-TS 224 CR-38SX60-TS 183 CCR-38SX60 184 CCR-38SX60-D 185 CCR-38SX60-DM 186 CCR-38SX60-M 187 CCR-38SX60-MS 188 CCR-38SX60-S 189 CCR-38SX60-T 190 CCR-38SX60-TD 191 CCR-38SX60-TDM 192 CCR-38SX60-TDMS 193 CCR-38SX60-TDS 194 CCR-38SX60-TM 195 CCR-38SX60-TMS 196 CCR-38SX60-TS 197 CR-38SX6C 198 CR-38SX6C-D 199 CR-38SX6C-DM 200 CR-38SX6C-M 201 CR-38SX6C-MS 202 CR-38SX6C-S 203 CR-38SX6C-T 204 CR-38SX6C-TD 205 CR-38SX6C-TDM 206 CR-38SX6C-TDMS 207 CR-38SX6C-TDS 208 CR-38SX6C-TM 209 CR-38SX6C-TMS 210 CR-38SX6C-TS X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc) © 2013 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-38S/CR-38S Page 13 CCR-38S\CR-38S\072013\Q3