CLR130, CLR131, and CLR132 are exact
replacements for obsolete part numbers
CLR2169, CLR2170 and CLR2180.
0.210 (5.33)
0.190 (4.83)
0.190 (4.83)
0.176 (4.47)
April, 2002
0.500 (12.7) min
0.215 (5.46)
0.205 (5.21)
COLLECTOR
0.158 (4.01)
0.136 (3.45)
BASE
EMITTER
0.100 (2.54) dia
0.025 (0.64)
max
0.060 (1.52)
max
0.147 (3.73)
0.137 (3.48)
0.019 (0.48)
0.016 (0.41)
ALL DIMENSIONS ARE IN INCHES (MILLIMETERS)
Case 17
features
absolute maximum ratings (TA = 25°C unless otherwise stated)
storage temperature ....................................................................... -65°C to +150°C
• high sensitivity
operating temperature ................................................................... -65°C to +125°C
• ± 20° acceptance angle
lead soldering temperature(1) ......................................................................... 260°C
• custom aspheric lensed TO-18
collector-emitter voltage..................................................................................... 15V
• transistor base is bonded
continuous
collector current ............................................................................ 50mA
• usable throughout visible and near
continuous power dissipation(2) .................................................................... 250mW
infrared spectrum
• RoHS compliant
notes:
1. 0.06” (1.5mm) from the header for 5 seconds maximum
description
2. Derate linearly 2.0mW/°C from 25°C free air temperature to TA = +125°C.
The CLR130-CLR132 series are
NPN silicon photodarlingtons
mounted in TO-18 packages.
Photodarlingtons allow high
sensitivity at low irradiance levels. A
custom double convex glass-to-metal
sealed aspheric lens provides a
narrow acceptance angle for
excellent on-axis coupling. These
devices are mechanically
and spectrally matched to the
CLE130-CLE133 series IREDs. For
additional information, call Clairex.
electrical characteristics (TA = 25°C unless otherwise noted)
symbol
parameter
IL
Light current
ICEO
V(BR)CEO
min
typ
max
units
Collector dark current
0.5
2.0
4.0
-
-
100
mA
mA
mA
nA
Collector-emitter breakdown
(1)
CLR130
CLR131
CLR132
test conditions
VCE=5V, Ee=0.06mW/cm2
VCE=10V, Ee=0
15
-
-
V
IC=100µA
tr
Output time
-
100
-
µs
VCE=5V, RL=100Ω.
tf
Output fall time
-
150
-
µs
VCE=5V, RL=100Ω.
Total angle at half sensitivity points
-
40
-
deg.
θHP
note: 1. Radiation source for all light current testing is a 940nm IRED.