CUI CFM-A225-43 Dc axial fan Datasheet

For more information, please visit the product page.
date
08/15/2016
page
1 of 6
SERIES: CFM-120 │ DESCRIPTION: DC AXIAL FAN
FEATURES
•
•
•
•
120 x 120 mm frame
high fan speed for greater air flow
two ball bearing construction
auto restart protection standard on all models
MODEL
input
voltage
input
current
input
power
rated
speed
airflow1
static
pressure2
noise
rated
(Vdc)
range
(Vdc)
typ
(A)
max
(A)
max
(W)
typ
(RPM)
(CFM)
(mm H2O)
max
(dBA)
CFM-A225-13
12
6~13.8
0.59
0.79
9.48
4,100
126.89
12.52
53.5
CFM-A225-23
24
16~27.6
0.31
0.39
9.36
4,100
126.89
12.52
53.5
CFM-A225-43
48
30~55.2
0.17
0.23
11.04
4,100
126.89
12.52
53.5
CFM-A238-13
12
6~13.8
1.40
1.75
21
4,600
200.9
19.80
61.5
CFM-A238-23
24
16~27.6
0.77
0.88
21.12
4,600
200.9
19.80
61.5
CFM-A238-43
48
30~55.2
0.36
0.48
23.04
4,600
200.9
19.80
61.5
Notes:
1. At 0 mm H20 static pressure.
2. At 0 CFM airflow.
PART NUMBER KEY
CFM-A2 XX - X 3 - XX - CXX
Base Number
Depth
25 = 25 mm
38 = 38 mm
Reserved for Custom
Configurations
Input Voltage
1 = 12 Vdc
2 = 24 Vdc
4 = 48 Vdc
cui.com
Fan Protection
10 = auto restart protection
11 = auto restart protection / rotation detector
20 = auto restart protection / tachometer signal
22 = auto restart protection / tachometer signal /
PWM control signal
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-120 │ DESCRIPTION: DC AXIAL FAN
date 08/15/2016 │ page 2 of 6
INPUT
parameter
conditions/description
operating input voltage
12 Vdc input models
24 Vdc input models
48 Vdc input models
min
typ
max
units
6
16
30
12
24
48
13.8
27.6
55.2
Vdc
Vdc
Vdc
current
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
0.59
0.31
0.17
1.40
0.77
0.36
0.79
0.39
0.23
1.75
0.88
0.48
A
A
A
A
A
A
power
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
7.08
7.44
8.16
16.80
18.48
17.28
9.48
9.36
11.04
21
21.12
23.04
W
W
W
W
W
W
starting voltage
at 25°C
12 Vdc input models
24 Vdc input models
48 Vdc input models
6
12
24
Vdc
Vdc
Vdc
PERFORMANCE
parameter
conditions/description
min
typ
max
units
rated speed
at 25°C, after 10 minutes
CFM-A225 models
CFM-A238 models
3,690
4,140
4,100
4,600
4,510
5,060
RPM
RPM
air flow
at 0 mm H2O, see performance curves
CFM-A225 models
CFM-A238 models
static pressure
at 0 CFM, see performance curves
CFM-A225 models
CFM-A238 models
noise
at 1 m
CFM-A225 models
CFM-A238 models
126.89
200.9
CFM
CFM
12.52
19.80
mm H2O
mm H2O
51.5
59.5
53.5
61.5
dBA
dBA
min
typ
max
units
min
typ
max
units
PROTECTIONS / SIGNALS1
parameter
conditions/description
auto restart protection
available on all models
rotation detector
available on “11” models
tachometer signal
available on “20” and “22” models
PWM control signal
available on “22” models
Notes:
1. See application notes for details.
SAFETY & COMPLIANCE
parameter
conditions/description
insulation resistance of frame
at 500 Vdc between frame and positive terminal
dielectric strength
at 500 Vac, 60 Hz, 1 minute between frame and
positive terminal
safety approvals
UL/cUL 507, TUV (EN 60950-1)
EMI/EMC
EN 55022:2010+AC:2011 Class B, EN 61000-32:2014, EN 61000-3-3:2013, EN 55024:2010
life expectancy
at 45°C, 15~65% RH
RoHS
2011/65/EU
10
MΩ
5
70,000
cui.com
mA
hours
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-120 │ DESCRIPTION: DC AXIAL FAN
date 08/15/2016 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
max
units
-10
typ
70
°C
-40
70
°C
operating humidity
non-condensing
5
90
%
storage humidity
non-condensing
5
95
%
PERFORMANCE CURVES
0.50
0.40
CFM-A238
(mm H2O)
(Inch H2O)
CFM-A225
14.00
0.98
12.00
.
.
10.00
0.30
0.20
.
8.00
6.00
10.
4.00
0.10
0.00
.
2.00
0.00
0.00
0.00
50.00
100.00
150.00 (CFM)
0.
0.
(CMM)
0.00
0.74
1.49
2.23
2.98
3.72
0.00
cui.com
.
100.
.
.
.
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-120 │ DESCRIPTION: DC AXIAL FAN
date 08/15/2016 │ page 4 of 6
MECHANICAL
parameter
conditions/description
motor
4 pole DC brushless
min
bearing system
ball bearing
direction of rotation
counter-clockwise viewed from front of fan blade
dimensions
CFM-A225 models 120 x 120 x 25.4
CFM-A238 models 120 x 120 x 38
material
PBT (UL94V-0)
weight
CFM-A225-13
CFM-A225-23
CFM-A225-43
CFM-A238-13
CFM-A238-23
CFM-A238-43
units: mm [inch]
CFM-A225
wire: UL 1007, 24 AWG
WIRE CONNECTIONS
Function
Red
+Vin
Black
-Vin
Yellow
FG Signal
White
RD Signal
Blue
PWM
ōŢţŦŭ
CFM-A238
wire: UL 1007, 24 AWG
WIRE CONNECTIONS
Wire Color
Function
Red
+Vin
Black
-Vin
Yellow
FG Signal
White
RD Signal
Blue
PWM
ōŢţŦŭ
cui.com
max
units
mm
mm
190.0
189.8
190.6
297.0
283.7
283.2
MECHANICAL DRAWING
Wire Color
typ
g
g
g
g
g
g
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-120 │ DESCRIPTION: DC AXIAL FAN
date 08/15/2016 │ page 5 of 6
APPLICATION NOTES
Auto Restart Protection/Current Limit Protection
When the fan motor is locked, the device will cut off the drive current within two to six seconds and restart automatically
after a few seconds. If the lock situation is continued, the device will work on a repeated cycle of cut-off and restart until
the lock is released. (See Figure 1 below).
Figure 1 Current Limit Protection
Lock Sensor/Rotation Detector
Lock Sensor is used to detect if the fan motor is operating or stopped. Alarm High: the output will be logical low when fan
is operating and be logical high when fan motor is locked. (See Figures 2~3 below).
Figure 3 RD Signal Output Circuit:
Open Collector
Figure 2 Alarm High
Output Waveform
Ic=5mA max
Pulse Sensor/Tachometer Signal/FG
Pulse Sensor is for detecting the rotational speed of the fan motor. At locked rotor condition, the signal stops cycling and
the output is fixed at VoH or VoL (See Figures 4~5 below).
Figure 4 Output Waveform
Figure 5 FG Signal Output Circuit:
Open Collector
Ic=10mA max
PMW Control Signal
A speed control lead can be provided that will accept a PWM signal from the customer circuit to vary the speed of the fan.
The change in speed is linear by changing the Duty-Cycle of the PWM. Open collector type and pull-up voltage is changed
by maximum operating voltage and sink current by consuming current. (See Figure 6 below).
Figure 6 Duty Cycle
Vs=4~5 V
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-120 │ DESCRIPTION: DC AXIAL FAN
date 08/15/2016 │ page 6 of 6
REVISION HISTORY
rev.
1.0
description
date
initial release
08/15/2016
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
Similar pages