ETC2 BXRC-27E10K0-D-7 Bridgelux vero se 29 array sery Datasheet

Bridgelux Vero SE 29 Array Series
®
®
Product Data Sheet DS123
1
Vero SE
Introduction
Vero® SE is a revolutionary light source system that integrates Bridgelux’s seventh generation COB technology with poke-in
connectivity enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower manufacturing
cost, simplify luminaire design, improve light quality and increase design flexibility.
Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current
range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays
into fixtures and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam
control and precision lighting with 2 and 3 SDCM color control standards for clean and consistent uniform lighting.
Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched
LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor
Series color points are available on Vero® SE Series, Vero® Series, V Series™ and H Series™.
Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color
tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums.
Décor Series Ultra is designed as a replacement for halogen lamps
Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and
restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series
Food products are a must have for any butcher counter or bakery.
Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment
industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these
industries.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Features
• Poke-in connectivity
• Efficacy of 155 lm/W typical
• Lumen output performance ranges from 5,368 to
37,173 lumens
Benefits
• Poke-in connectivity enables solderless, connector
free installation
• Broad application coverage for interior and exterior
lighting
• Broad range of CCT options from 1750K to 6500K
• Flexibility for application driven lighting design
requirements
• CRI options: minimum 65, 70, 80, and 90
• High quality, true color reproduction
• Color control: 2 and 3 SDCM for 2700K-4000K CCT
• Uniform consistent white light
• Reliable operation at up to 2X nominal drive current
• Flexibility in design optimization
• Radial die pattern and improved lumen density
• Enhanced ease of use and assembly
• Top side part number markings
• No exposed solder pads or electrical connections
• Ability to configure multiple arrays in series and
parallel reduces customer driver cost
• Vf bin code backside marking
• Improved inventory management and quality control
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
8
Electrical Characteristics
16
Eye Safety
17
Absolute Maximum Ratings
18
Performance Curves
19
Typical Radiation Pattern
23
Typical Color Spectrum
24
Mechanical Dimensions
25
Color Binning Information
26
Packaging and Labeling
27
Design Resources
29
Precautions
29
Disclaimers
29
About Bridgelux
30
1
Product Feature Map
Vero SE 29 is the largest form factor in the product family
of next generation solid state light sources. In addition to
delivering the performance and light quality required for
many lighting applications, Vero SE incorporates several
features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero SE Series family of products.
2D Bar code provides full
manufacturing traceability
Polarity indication marks simplify
manufacturing operator instructions
Wire release mechanisms x4
Tc Measurement point
Optic mounting holes
Radial die configuration improves lumen
density and beam control
Mounting holes
Top side part number marking improves
inventory management and outgoing
quality control
Test ports for probing
Dual poke-in connectivity
Product Nomenclature
The part number designation for Bridgelux Vero SE LED arrays is explained as follows:
1 2 3 4
–
56
7
8 9 10 11
–
12
– 13 14
– 15 16
BXRC – 30 E 10K 0 – C – 7 3 – SE
Product Family
Nominal CCT
17 = 1,750K
20 = 2,000K
25 = 2,500K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
56 = 5,600K
57 = 5,700K
65 = 6,500K
Special Edition
CCT Bin Options
Gen. 7
Array Configuration
CRI
B = 65 CRI min.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
A = Class A
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
Flux Indicator
10Kx = 10,000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal
Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E10K0-B-74-SE
1750
80
1800
8033
7230
52.0
93.6
86
BXRC-17E10K0-C-74-SE
1750
80
1710
10175
9157
69.4
118.7
86
BXRC-17E10K0-D-74-SE
1750
80
2100
6768
6092
37.6
79.0
86
145
BXRC-20B10K1-C-73-SE
2000
65
1710
17155
15440
69.4
118.7
BXRC-20B10K1-D-73-SE
2000
65
2100
11411
10270
37.6
79.0
145
BXRC-25E10K0-B-74-SE
2500
80
1800
12983
11685
52.0
93.6
139
139
BXRC-25E10K0-C-74-SE
2500
80
1710
16446
14801
69.4
118.7
BXRC-25E10K0-D-74-SE
2500
80
2100
10940
9845
37.6
79.0
139
BXRC-27E10K0-B-7x-SE
2700
80
1800
13899
12509
52.0
93.6
148
BXRC-27E10K0-C-7x-SE
2700
80
1710
17605
15844
69.4
118.7
148
BXRC-27E10K0-D-7x-SE
2700
80
2100
11711
10540
37.6
79.0
148
BXRC-27G10K0-B-7x-SE
2700
90
1800
11582
10424
52.0
93.6
124
BXRC-27G10K0-C-7x-SE
2700
90
1710
14671
13204
69.4
118.7
124
BXRC-27G10K0-D-7x-SE
2700
90
2100
9759
8783
37.6
79.0
124
BXRC-27H10K0-D-74-SE
2700
97
2100
8510
7659
37.6
79.0
108
BXRC-30E10K0-B-7x-SE10
3000
80
1800
14478
13030
52.0
93.6
155
BXRC-30E10K0-C-7x-SE10
3000
80
1710
18339
16505
69.4
118.7
155
BXRC-30E10K0-D-7x-SE
3000
80
2100
12565
10979
37.6
79.0
159
BXRC-30G10K0-B-7x-SE
3000
90
1800
12017
10815
52.0
93.6
128
BXRC-30G10K0-C-7x-SE
3000
90
1710
15221
13699
69.4
118.7
128
BXRC-30G10K0-D-7x-SE
3000
90
2100
10125
9112
37.6
79.0
128
BXRC-30H10K0-D-7X-SE
3000
97
2100
9062
8156
37.6
79.0
115
BXRC-30A10K1-B-73-SE8,9
3000
93
1800
11209
10088
52.0
93.6
120
BXRC-30A10K1-C-73-SE8,9
3000
93
1710
14197
12778
69.4
118.7
120
8,9
BXRC-30A10K1-D-73-SE
3000
93
2100
9444
8500
37.6
79.0
120
BXRC-35E10K0-B-7x-SE10
3500
80
1800
14912
13421
52.0
93.6
159
BXRC-35E10K0-C-7x-SE10
3500
80
1710
18889
16999
69.4
118.7
159
BXRC-35E10K0-D-7x-SE10
3500
80
2100
12565
11309
37.6
79.0
159
BXRC-35G10K0-B-7x-SE
3500
90
1800
12451
11206
52.0
93.6
133
BXRC-35G10K0-C-7x-SE
3500
90
1710
15771
14194
69.4
118.7
133
BXRC-35G10K0-D-7x-SE
3500
90
2100
10491
9442
37.6
79.0
133
BXRC-35A10K1-B-73-SE8,9
3500
93
1800
12050
10845
52.0
93.6
129
BXRC-35A10K1-C-73-SE8,9
3500
93
1710
15263
13737
69.4
118.7
129
BXRC-35A10K1-D-73-SE8,9
3500
93
2100
10153
9137
37.6
79.0
129
10
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums
for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI
Nominal
Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
2
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-40E10K0-B-7x-SE10
4000
80
1800
15057
13551
52.0
93.6
161
BXRC-40E10K0-C-7x-SE10
4000
80
1710
19072
17165
69.4
118.7
161
BXRC-40E10K0-D-7x-SE10
4000
80
2100
12687
11418
37.6
79.0
161
BXRC-40G10K0-B-7x-SE
4000
90
1800
12885
11597
52.0
93.6
138
BXRC-40G10K0-C-7x-SE
4000
90
1710
16321
14689
69.4
118.7
138
BXRC-40G10K0-D-7x-SE
4000
90
2100
10857
9772
37.6
79.0
138
BXRC-40A10K1-B-73-SE8,9
4000
93
1800
12890
11601
52.0
93.6
138
BXRC-40A10K1-C-73-SE8,9
4000
93
1710
16327
14694
69.4
118.7
138
BXRC-40A10K1-D-73-SE8,9
4000
93
2100
10861
9775
37.6
79.0
138
BXRC-50C10K1-B-7x-SE10
5000
70
1800
16505
14855
52.0
93.6
176
BXRC-50C10K1-C-7x-SE10
5000
70
1710
20906
18816
69.4
118.7
176
BXRC-50C10K1-D-7x-SE10
5000
70
2100
13907
12516
37.6
79.0
176
BXRC-50E10K1-B-7x-SE10
5000
80
1800
15515
13963
52.0
93.6
166
BXRC-50E10K1-C-7x-SE10
5000
80
1710
19652
17687
69.4
118.7
166
BXRC-50E10K1-D-7x-SE10
5000
80
2100
13072
11766
37.6
79.0
166
BXRC-50G10K1-B-7x-SE
5000
90
1800
13204
11883
52.0
93.6
141
BXRC-50G10K1-C-7x-SE
5000
90
1710
16725
15052
69.4
118.7
141
BXRC-50G10K1-D-7x-SE
5000
90
2100
11125
10013
37.6
79.0
141
BXRC-56G10K0-B-74-SE
5600
90
1800
13824
12442
52.0
93.6
148
BXRC-56G10K0-C-74-SE
5600
90
1710
17510
15760
69.4
118.7
148
BXRC-56G10Kx-D-74-SE
5600
90
2100
11648
10483
37.6
79.0
148
BXRC-56H10K0-D-74-SE
5600
97
2100
10638
9574
37.6
79.0
135
BXRC-57C10K1-B-7x-SE10
5700
70
1800
15926
14333
52.0
93.6
170
BXRC-57C10K1-C-7x-SE10
5700
70
1710
20172
18155
69.4
118.7
170
10
BXRC-57C10K1-D-7x-SE
5700
70
2100
13419
12077
37.6
79.0
170
BXRC-57E10K1-B-7x-SE10
5700
80
1800
15781
14202
52.0
93.6
169
BXRC-57E10K1-C-7x-SE10
5700
80
1710
19989
17990
69.4
118.7
168
BXRC-57E10K1-D-7x-SE10
5700
80
2100
13297
11967
37.6
79.0
168
BXRC-65C10K1-B-7x-SE10
6500
70
1800
16215
14593
52.0
93.6
173
BXRC-65C10K1-C-7x-SE10
6500
70
1710
20539
18486
69.4
118.7
173
BXRC-65C10K1-D-7x-SE10
6500
70
2100
13663
12296
37.6
79.0
173
10
BXRC-65E10K1-B-7x-SE
6500
80
1800
16070
14464
52.0
93.6
172
BXRC-65E10K1-C-7x-SE10
6500
80
1710
20356
18320
69.4
118.7
172
BXRC-65E10K1-D-7x-SE10
6500
80
2100
13541
12186
37.6
79.0
171
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all
other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is
93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
4
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A10K1-B-73-SE
3000
80
93
1800
10424
9382
50.9
91.6
114
BXRC-30A10K1-C-73-SE
3000
80
93
1710
13204
11884
67.9
116.1
114
BXRC-30A10K1-D-73-SE
3000
80
93
2100
8783
7905
36.8
77.3
114
BXRC-35A10K1-B-73-SE
3500
80
93
1800
11206
10086
50.9
91.6
122
BXRC-35A10K1-C-73-SE
3500
80
93
1710
14194
12775
67.9
116.1
122
BXRC-35A10K1-D-73-SE
3500
80
93
2100
9442
8498
36.8
77.3
122
BXRC-40A10K1-B-73-SE
4000
80
93
1800
11987
10789
50.9
91.6
131
BXRC-40A10K1-C-73-SE
4000
80
93
1710
15184
13666
67.9
116.1
131
BXRC-40A10K1-D-73-SE
4000
80
93
2100
10101
9090
36.8
77.3
131
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
5
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal
CCT1 (K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E10K0-B-74-SE
1750
80
1800
7230
6507
50.7
91.2
79
BXRC-17E10K0-C-74-SE
1750
80
1710
9157
8241
68.1
116.4
79
BXRC-17E10K0-D-74-SE
1750
80
2100
6091
5483
36.6
76.8
79
BXRC-20B10K1-C-73-SE
2000
65
1710
15440
13896
68.1
116.4
133
BXRC-20B10K1-D-73-SE
2000
65
2100
10270
9243
36.6
76.8
134
128
BXRC-25E10K0-B-74-SE
2500
80
1800
11685
10516
50.7
91.2
BXRC-25E10K0-C-74-SE
2500
80
1710
14801
13321
68.1
116.4
127
BXRC-25E10K0-D-74-SE
2500
80
2100
9846
8861
36.6
76.8
128
BXRC-27E10K0-B-7x-SE
2700
80
1800
12509
11258
50.7
91.2
137
BXRC-27E10K0-C-7x-SE
2700
80
1710
15845
14260
68.1
116.4
136
BXRC-27E10K0-D-7x-SE
2700
80
2100
10540
9486
36.6
76.8
137
114
BXRC-27G10K0-B-7x-SE
2700
90
1800
10424
9381
50.7
91.2
BXRC-27G10K0-C-7x-SE
2700
90
1710
13204
11884
68.1
116.4
113
BXRC-27G10K0-D-7x-SE
2700
90
2100
8783
7905
36.6
76.8
114
BXRC-27H10K0-D-74-SE
2700
97
2100
7659
6893
7404
76.8
100
BXRC-30E10K0-B-7x-SE
3000
80
1800
13030
11727
50.7
91.2
143
BXRC-30E10K0-C-7x-SE
3000
80
1710
16505
14854
68.1
116.4
142
BXRC-30E10K0-D-7x-SE
3000
80
2100
11309
9882
36.6
76.8
147
BXRC-30G10K0-B-7x-SE
3000
90
1800
10815
9733
50.7
91.2
119
BXRC-30G10K0-C-7x-SE
3000
90
1710
13699
12329
68.1
116.4
118
BXRC-30G10K0-D-7x-SE
3000
90
2100
9113
8201
36.6
76.8
119
BXRC-30H10K0-D-7X-SE
3000
97
2100
8156
7340
36.6
76.8
106
BXRC-30A10K1-B-73-SE7,8
3000
93
1800
10088
9079
50.7
91.2
111
BXRC-30A10K1-C-73-SE7,8
3000
93
1710
12778
11500
68.1
116.4
110
BXRC-30A10K1-D-73-SE7,8
3000
93
2100
8500
7650
36.6
76.8
111
BXRC-35E10K0-B-7x-SE
3500
80
1800
13421
12079
50.7
91.2
147
BXRC-35E10K0-C-7x-SE
3500
80
1710
17000
15299
68.1
116.4
146
BXRC-35E10K0-D-7x-SE
3500
80
2100
11308
10178
36.6
76.8
147
BXRC-35G10K0-B-7x-SE
3500
90
1800
11206
10085
50.7
91.2
123
BXRC-35G10K0-C-7x-SE
3500
90
1710
14194
12775
68.1
116.4
122
BXRC-35G10K0-D-7x-SE
3500
90
2100
9442
8498
36.6
76.8
123
BXRC-35A10K1-B-73-SE7,8
3500
93
1800
10845
9760
50.7
91.2
119
BXRC-35A10K1-C-73-SE7,8
3500
93
1710
13736
12363
68.1
116.4
118
BXRC-35A10K1-D-73-SE7,8
3500
93
2100
9137
8223
36.6
76.8
119
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2.All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums
for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal
CCT1 (K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
149
BXRC-40E10K0-B-7x-SE
4000
80
1800
13551
12196
50.7
91.2
BXRC-40E10K0-C-7x-SE
4000
80
1710
17165
15448
68.1
116.4
147
BXRC-40E10K0-D-7x-SE
4000
80
2100
11418
10277
36.6
76.8
149
BXRC-40G10K0-B-7x-SE
4000
90
1800
11597
10437
50.7
91.2
127
BXRC-40G10K0-C-7x-SE
4000
90
1710
14689
13220
68.1
116.4
126
BXRC-40G10K0-D-7x-SE
4000
90
2100
9771
8794
36.6
76.8
127
BXRC-40A10K1-B-73-SE7,8
4000
93
1800
11601
10441
50.7
91.2
127
7,8
BXRC-40A10K1-C-73-SE
4000
93
1710
14694
13225
68.1
116.4
126
BXRC-40A10K1-D-73-SE7,8
4000
93
2100
9775
8797
36.6
76.8
127
BXRC-50C10K1-B-7x-SE
5000
70
1800
14854
13369
50.7
91.2
163
BXRC-50C10K1-C-7x-SE
5000
70
1710
18815
16934
68.1
116.4
162
BXRC-50C10K1-D-7x-SE
5000
70
2100
12516
11264
36.6
76.8
163
BXRC-50E10K1-B-7x-SE
5000
80
1800
13963
12567
50.7
91.2
153
BXRC-50E10K1-C-7x-SE
5000
80
1710
17686
15918
68.1
116.4
152
BXRC-50E10K1-D-7x-SE
5000
80
2100
11765
10589
36.6
76.8
153
BXRC-50G10K1-B-7x-SE
5000
90
1800
11883
10695
50.7
91.2
130
BXRC-50G10K1-C-7x-SE
5000
90
1710
15052
13547
68.1
116.4
129
BXRC-50G10K1-D-7x-SE
5000
90
2100
10013
9012
36.6
76.8
130
BXRC-56G10K0-B-74-SE
5600
90
1800
12442
11198
50.7
91.2
136
BXRC-56G10K0-C-74-SE
5600
90
1710
15759
14184
68.1
116.4
135
BXRC-56G10Kx-D-74-SE
5600
90
2100
10483
9434
36.6
76.8
137
BXRC-56H10K0-D-74-SE
5600
97
2100
9574
8617
36.6
76.8
125
BXRC-57C10K1-B-7x-SE
5700
70
1800
14333
12900
50.7
91.2
157
BXRC-57C10K1-C-7x-SE
5700
70
1710
18155
16340
68.1
116.4
156
BXRC-57C10K1-D-7x-SE
5700
70
2100
12077
10869
36.6
76.8
157
BXRC-57E10K1-B-7x-SE
5700
80
1800
14203
12782
50.7
91.2
156
BXRC-57E10K1-C-7x-SE
5700
80
1710
17990
16191
68.1
116.4
155
BXRC-57E10K1-D-7x-SE
5700
80
2100
11967
10770
36.6
76.8
156
BXRC-65C10K1-B-7x-SE
6500
70
1800
14594
13134
50.7
91.2
160
BXRC-65C10K1-C-7x-SE
6500
70
1710
18485
16637
68.1
116.4
159
BXRC-65C10K1-D-7x-SE
6500
70
2100
12297
11067
36.6
76.8
160
159
BXRC-65E10K1-B-7x-SE
6500
80
1800
14463
13017
50.7
91.2
BXRC-65E10K1-C-7x-SE
6500
80
1710
18320
16488
68.1
116.4
157
BXRC-65E10K1-D-7x-SE
6500
80
2100
12187
10968
36.6
76.8
159
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums
for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
7
Performance at Commonly Used Drive Currents
Vero SE LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-17E10K0-B-74-SE
80
BXRC-17E10K0-C-74-SE
80
BXRC-17E10K0-D-74-SE
80
BXRC-20B10K1-C-73-SE
65
BXRC-20B10K1-D-73-SE
65
BXRC-25E10K0-B-74-SE
80
BXRC-25E10K0-C-74-SE
80
BXRC-25E10K0-D-74-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
4170
5491
8033
11579
14820
5780
7346
10175
14434
18091
3723
4791
6768
9635
12144
9745
12386
17155
24336
30503
6277
8078
11411
16245
20475
6740
8875
12983
18715
23954
9342
11874
16446
23330
29242
6017
7744
10940
15574
19629
3807
4991
7230
10327
13058
5500
6776
9157
12414
15202
3627
4459
6091
8119
9917
9273
11425
15440
20931
25631
6116
7518
10270
13688
16719
6152
8067
11685
16691
21105
8890
10953
14801
20066
24572
5863
7207
9846
13123
16029
93
91
86
79
74
102
96
86
78
71
100
95
86
77
70
172
161
145
132
120
169
160
145
131
118
151
147
139
128
119
165
155
139
126
115
162
153
139
125
113
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27E10K0-B-7x-SE
80
BXRC-27E10K0-C-7x-SE
80
BXRC-27E10K0-D-7x-SE
80
BXRC-27G10K0-B-7x-SE
90
BXRC-27G10K0-C-7x-SE
90
BXRC-27G10K0-D-7x-SE
90
BXRC-27H10K0-D-74-SE
97
BXRC-30E10K0-B-7x-SE
80
BXRC-30E10K0-C-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
7215
9500
13899
20035
25642
10001
12711
17605
24975
31304
6442
8290
11711
16672
21013
6013
7917
11582
16696
21369
8334
10593
14671
20812
26086
5368
6908
9759
13894
17511
4681
6024
8510
12115
15269
7516
9896
14478
20870
26711
10418
13241
18339
26016
32608
6586
8636
12509
17867
22593
9517
11725
15845
21480
26304
6276
7715
10540
14048
17159
5488
7197
10424
14890
18827
7931
9771
13204
17900
21920
5230
6429
8783
11707
14299
4561
5606
7659
10208
12469
6861
8996
13030
18612
23534
9913
12214
16505
22375
27400
162
157
148
137
128
177
166
148
135
123
173
164
148
134
122
135
131
124
114
106
147
138
124
113
102
144
136
124
112
101
126
119
108
97
88
168
163
155
143
133
184
173
155
141
128
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
9
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30E10K0-D-7x-SE
80
BXRC-30G10K0-B-7x-SE
90
BXRC-30G10K0-C-7x-SE
90
BXRC-30G10K0-D-7x-SE
90
BXRC-30H10K0-D-7x-SE
97
BXRC-30A10K1-B-73-SE
93
BXRC-30A10K1-C-73-SE
93
BXRC-30A10K1-D-73-SE
93
BXRC-35E10K0-B-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
6912
8895
12565
17889
22546
6238
8214
12017
17322
22170
8647
10990
15221
21593
27065
5569
7168
10125
14415
18167
4985
6415
9062
12901
16260
5819
7662
11209
16157
20680
8065
10251
14197
20141
25245
5195
6686
9444
13445
16946
7741
10193
14912
21496
27512
6734
8278
11309
15073
18411
5694
7466
10815
15448
19533
8228
10137
13699
18572
22742
5427
6670
9113
12146
14835
4857
5970
8156
10870
13278
5312
6965
10088
14409
18220
7675
9456
12778
17323
21212
5062
6222
8500
11329
13838
7066
9266
13421
19170
24240
186
176
159
144
130
140
136
128
119
110
153
143
128
117
106
150
142
128
116
105
134
127
115
104
94
130
127
120
111
103
143
134
120
109
99
140
132
120
108
98
173
168
159
147
137
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-35E10K0-C-7x-SE
80
BXRC-35E10K0-D-7x-SE
80
BXRC-35G10K0-B-7x-SE
90
BXRC-35G10K0-C-7x-SE
90
BXRC-35G10K0-D-7x-SE
90
BXRC-35A10K1-B-73-SE
93
BXRC-35A10K1-C-73-SE
93
BXRC-35A10K1-D-73-SE
93
BXRC-40E10K0-B-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
10730
13638
18889
26796
33586
6911
8895
12565
17888
22545
6464
8511
12451
17948
22971
8959
11387
15771
22373
28043
5771
7427
10491
14936
18824
6255
8237
12050
17370
22231
8670
11020
15263
21652
27139
5584
7187
10153
14454
18217
7816
10292
15057
21704
27779
10211
12580
17000
23047
28222
6734
8278
11308
15072
18410
5900
7736
11206
16006
20239
8525
10504
14194
19243
23564
5623
6912
9442
12585
15372
5710
7487
10845
15490
19587
8251
10165
13736
18622
22804
5441
6689
9137
12178
14876
7135
9356
13551
19356
24476
190
178
159
145
132
186
176
159
144
130
145
141
133
123
114
158
148
133
121
110
155
147
133
120
109
140
136
129
119
111
153
144
129
117
107
150
142
129
116
105
175
170
161
149
138
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40E10K0-C-7x-SE
80
BXRC-40E10K0-D-7x-SE
80
BXRC-40G10K0-B-7x-SE
90
BXRC-40G10K0-C-7x-SE
90
BXRC-40G10K0-D-7x-SE
90
BXRC-40A10K1-B-73-SE
93
BXRC-40A10K1-C-73-SE
93
BXRC-40A10K1-D-73-SE
93
BXRC-50C10K1-B-74-SE
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
10834
13770
19072
27056
33912
6978
8981
12687
18062
22764
6689
8808
12885
18574
23773
9272
11784
16321
23154
29021
5972
7686
10857
15457
19481
6691
8811
12890
18580
23781
9275
11788
16327
23162
29031
5974
7688
10861
15462
19487
8568
11282
16505
23791
30450
10310
12702
17165
23270
28496
6800
8358
11418
15219
18589
6106
8006
11597
16565
20945
8823
10870
14689
19914
24386
5819
7153
9771
13024
15908
6108
8009
11601
16570
20953
8826
10874
14694
19921
24394
5821
7155
9775
13028
15913
7821
10255
14854
21218
26829
191
180
161
146
133
188
177
161
145
132
150
145
138
127
118
164
154
138
125
114
160
152
138
124
113
150
145
138
127
118
164
154
138
125
114
161
152
138
124
113
192
186
176
163
151
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50C10K1-C-74-SE
70
BXRC-50C10K1-D-74-SE
70
BXRC-50E10K1-B-74-SE
80
BXRC-50E10K1-C-74-SE
80
BXRC-50E10K1-D-74-SE
80
BXRC-50G10K1-B-74-SE
90
BXRC-50G10K1-C-74-SE
90
BXRC-50G10K1-D-74-SE
90
BXRC-56G10K0-B-74-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
11876
15094
20906
29658
37173
7649
9845
13907
19798
24953
8054
10605
15515
22364
28623
11163
14189
19652
27878
34943
7190
9254
13072
18610
23456
6854
9025
13204
19033
24360
9501
12076
16725
23726
29738
6120
7876
11125
15839
19962
7177
9449
13824
19928
25505
11301
13924
18815
25508
31236
7453
9162
12516
16682
20376
7352
9640
13963
19945
25219
10623
13088
17686
23977
29362
7006
8612
11765
15681
19154
6257
8204
11883
16974
21463
9041
11139
15052
20406
24989
5963
7329
10013
13345
16301
6551
8590
12442
17772
22472
210
197
176
160
146
206
194
176
159
144
180
175
166
153
142
197
185
166
151
137
193
183
166
150
136
153
149
141
130
121
168
157
141
128
117
164
156
141
127
115
161
156
148
136
127
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-56G10K0-C-74-SE
80
BXRC-56G10Kx-D-74-SE
80
BXRC-56H10K0-D-74-SE
80
BXRC-57C10K1-B-74-SE
70
BXRC-57C10K1-C-74-SE
70
BXRC-57C10K1-D-74-SE
70
BXRC-57E10K1-B-74-SE
80
BXRC-57E10K1-C-74-SE
80
BXRC-57E10K1-D-74-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
9947
12643
17510
24840
31135
6407
8245
11648
16582
20900
5851
7531
10638
15145
19088
8267
10886
15926
22957
29382
11459
14565
20172
28617
35869
7381
9499
13419
19104
24077
8192
10787
15781
22748
29115
11355
14432
19989
28357
35543
7314
9413
13297
18930
23859
9465
11662
15759
21364
26162
6243
7674
10483
13972
17066
5701
7008
9574
12761
15587
7547
9895
14333
20473
25888
10905
13435
18155
24613
30140
7192
8840
12077
16097
19661
7478
9805
14203
20287
25652
10805
13313
17990
24389
29866
7126
8760
11967
15950
19483
176
165
148
134
122
172
163
148
133
121
157
149
135
122
110
185
180
170
157
146
203
190
170
155
141
198
188
170
154
139
183
178
169
156
145
201
188
168
153
140
197
186
168
152
138
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-65C10K1-B-74-SE
70
BXRC-65C10K1-C-74-SE
70
BXRC-65C10K1-D-74-SE
70
BXRC-65E10K1-B-74-SE
80
BXRC-65E10K1-C-7x-SE
80
BXRC-65E10K1-D-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
8418
11084
16215
23374
29916
11668
14830
20539
29137
36521
7515
9672
13663
19451
24515
8343
10985
16070
23165
29649
11564
14697
20356
28877
36195
7448
9586
13541
19277
24296
7684
10075
14594
20845
26358
11103
13679
18485
25060
30688
7323
9001
12297
16389
20019
7615
9985
14463
20659
26123
11004
13557
18320
24837
30414
7257
8921
12187
16243
19840
188
183
173
160
149
206
193
173
158
143
202
191
173
156
142
187
181
172
159
147
204
192
172
156
142
200
189
171
155
140
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx10Kx-B-7x-SE
BXRC-xxx10Kx-C-7x-SE
BXRC-xxx10Kx-D-7x-SE
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.06
46.1
57.5
-24.9
0.07
49.7
61.6
74.6
-33.2
0.04
61.5
76.8
74.4
80.0
-33.2
0.05
66.2
82.2
34.8
37.6
40.4
-17.4
0.06
33.4
41.6
38.1
41.2
44.3
-17.4
0.07
36.7
45.4
Minimum
Typical
Maximum
1800
48.1
52.0
55.9
-24.9
3600
51.7
55.8
60.0
1710
64.2
69.4
3420
68.8
2100
4200
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal
interface material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design
and selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The
working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product
application.
16
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx10Kx-B-7x-SE
BXRC-xxx10Kx-C-7x-SE
BXRC-xxx10Kx-D-7x-SE
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
1800
RG1
RG1
RG1
RG1
2700
RG1
RG1
RG2
RG2
3600
RG1
RG1
RG2
RG2
1710
RG1
RG1
RG1
RG2
2565
RG1
RG1
RG2
RG2
3420
RG1
RG2
RG2
RG2
2100
RG1
RG1
RG1
RG1
3150
RG1
RG1
RG1
RG2
4200
RG1
RG1
RG2
RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero SE Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC
62471 for the assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
17
Absolute Maximum Ratings
Table 7: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
125°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
BXRC-xxx10Kx-B-7x-SE
BXRC-xxx10Kx-C-7x-SE
BXRC-xxx10Kx-D-7x-SE
Maximum Drive Current3
3600mA
3420mA
4200mA
Maximum Peak Pulsed Drive Current4
5140mA
4890mA
6000mA
Maximum Reverse Voltage5
-90V
-120V
-65V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN121: Assembly Considerations for Bridgelux Vero SE LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
18
Performance Curves
Figure 2: Vero SE 29C Drive Current vs. Voltage
4000
4000
3500
3500
3000
3000
Forward Current (mA)
Forward Current (mA)
Figure 1: Vero SE 29B Drive Current vs. Voltage
2500
2000
1500
1000
2500
2000
1500
1000
500
0
500
47
48
49
50
51
52
53
54
55
56
57
0
58
63
64
65
66
67
68
Forward Voltage (V)
Figure 3: Vero SE 29D Drive Current vs. Voltage
71
72
73
74
75
76
200%
180%
4000
160%
Relative Luminous Flux
3500
Forward Current (mA)
70
Figure 4: Vero SE 29B Typical Relative Flux vs. Current
4500
3000
2500
2000
1500
1000
140%
120%
100%
80%
60%
40%
500
0
69
Forward Voltage (V)
20%
33
34
35
36
37
38
39
40
41
42
0%
0
Forward Voltage (V)
500
1000
1500
2000
2500
3000
3500
4000
Forward Current (mA)
Figure 6 Vero SE 29D Typical Relative Flux vs. Current
200%
200%
180%
180%
160%
160%
140%
140%
Relative Luminous Flux
Relative Luminous Flux
Figure 5: Vero SE 29C Typical Relative Flux vs. Current
120%
100%
80%
60%
120%
100%
80%
60%
40%
40%
20%
20%
0%
0
400
800
1200
1600
2000
2400
Forward Current (mA)
2800
3200
3600
4000
0%
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Forward Current (mA)
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
19
Performance Curves
Figure 7: Typical DC Flux vs. Case Temperature
Figure 8: Typical DC ccy Shift vs. Case Temperature
0
103%
Neutral White
50
75
100
125
0.000
Cool White
25°C Pulsed
97%
-0.003
ccy Shift
Relative Luminous Flux
100%
25
0.003
Warm White
94%
91%
-0.006
-0.009
88%
Warm White
-0.012
85%
-0.015
82%
0
25
50
75
100
Neutral White
Cool White
25°C Pulsed
125
Case Temperature (°C)
Case Temperature (°C)
Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature
Figure 9: Typical DC ccx Shift vs. Case Temperature
0.4101
0
25
50
75
100
0.41
125
0.4099
0.000
0.4098
-0.002
Pulsed Center
Point Tc=25°C
15°C
25°C
0.4097
ccy
ccx Shift
-0.004
-0.006
65°C
0.4093
Warm White
-0.012
0.4095
0.4094
-0.008
-0.010
45°C
0.4096
Neutral White
85°C
0.4092
Cool White
25°C Pulsed
105°C
0.4091
Case Temperature (°C)
0.409
0.525
0.526
0.527
0.528
0.529
0.53
0.531
0.532
ccx
Notes for Figures 7-9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. . For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
20
Performance Curves
Figure 11: 1750K Color Shift vs. Case Temperature1
Figure 12: 2500K Color Shift vs. Case Temperature1
0.3705
0.4145
Pulsed Center Point
Tc = 25°C
15°C
0.37
15°C
0.414
25°C
0.413
0.3695
0.369
ccy
ccy
45°C
85°C
0.411
105°C
0.52
70°C
85°C
0.4115
0.3685
0.5198
45°C
0.4125
0.412
70°C
0.368
0.5196
0.5202
0.5204
105°C
0.4105
0.468
0.5206
0.47
0.472
Figure 13: 5600K Color Shift vs. Case Temperature1,3
0.369
0.342
25°C
0.338
25°C
0.367
0.366
0.336
45°C
0.334
ccy
ccy
15°C
0.368
Pulsed Center
Point
Tc = 25°C
15°C
0.34
0.332
70°C
0.478
Pulsed
Center Point
Tc=25°C
45°C
0.365
0.364
70°C
0.363
85°C
0.328
0.476
Figure 14: 3000K Class A Color Shift vs. Case Temperature1
0.344
0.326
0.474
ccx
ccx
0.33
Pulsed
Center Point
Tc = 25°C
0.4135
25°C
85°C
0.362
105°C
0.361
0.324
0.322
0.32
0.322
0.324
0.326
0.328
105°C
0.36
0.416
0.33
0.4165
0.417
ccx
Figure 15: 3500K Class A Color Shift vs. Case Temperature1
ccx
0.4175
0.418
0.4185
Figure 16: 4000K Class A Color Shift vs. Case Temperature1
0.37
0.3760
15°C
0.368
Pulsed
Center Point
Tc=25°C
25°C
0.366
15°C
0.3740
25°C
0.3720
45°C
45°C
ccy
0.3700
ccy
Pulsed
Center Point
Tc=25°C
0.364
0.3680
70°C
0.362
85°C
0.36
85°C
0.3640
105°C
0.358
0.392
70°C
0.3660
105°C
0.393
0.394
0.395
0.396
0.397
ccx
0.3620
0.373
0.374
0.375
0.376
ccx
0.377
0.378
0.379
Note for Figures 10-16:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Color shift shown for product hot targeted at Tc=85°C
21
Performance Curves
Figure 17: Vero SE 29D Drive Current Derating Curve
4400
Drive Current (mA)
4200
4000
3960
3800
3600
3400
Max Drive Current
LM-80 Max Drive Current
3200
0
10
20
30
40
50
60
70
80
90
100
110
Case Temperature (⁰C)
Notes for Figure 17:
1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product
Feature Map (page 2) for the location of the Tc Point
2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections.
3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included
in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report.
22
Typical Radiation Pattern
Figure 18: Typical Spatial Radiation Pattern
Note for Figure 18:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 19: Typical Polar Radiation Pattern
23
Typical Color Spectrum
Figure 20: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 20:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
Figure 21: Typical Color Spectrum for Vero SE 29 with Décor Series
1
17E
20B
0.9
25E
27H
Relative Spectral Power Distribution
0.8
30H
56G
0.7
56H
0.6
0.5
0.4
0.3
0.2
0.1
0
400
450
500
550
600
Wavelength (nm)
650
700
750
800
Note for Figure 21:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
24
Mechanical Dimensions
Figure 22: Drawing for Vero SE 29 LED Array
Notes for Figure 22:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ± 0.10mm.
4. Mounting holes (2X) are for M3 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
25
Color Binning Information
Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space
0.44
2500K
4SDCM
3 SDCM
4 SDCM
2000K
3SDCM
2700K
0.42
3000K
3500K
0.4
Y
4000K
1750K
4SDCM
0.38
0.36
0.34
0.36
0.39
0.42
0.45
X
0.48
0.51
0.54
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
1750K
2500K
2700K
3000K1
3500K1
4000K1
ANSI Bin
(for reference only)
-
-
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
73 (3 SDCM)
-
-
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
72 (2 SDCM)
-
-
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.5167, 0.336)
(0.4765, 0.4137)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4073, 0.3917)
(0.3818, 0.3797)
Note for Table 8:
1. Color Binning information excludes Class A products. Please contact your Bridgelux Sales Representative for more information.
Figure 24: Graph of Cool White Test Bins in xy Color Space
0.39
4 SDCM
3 SDCM
0.38
0.37
5000K
0.36
5700K
Y
0.35
0.34
6500K
0.33
0.32
0.31
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5600K1
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5310K - 6020K)
(5312K - 6022K)
(6022K - 7042K)
74 (4 SDCM)
(4801K - 5282K)
(5475K - 5830K)
(5829K - 5481K)
(6270K - 6765K)
73 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3293, 0.3423)
(0.3287, 0.3417)
(0.3123, 0.3282)
Note for Table 9:
1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C.
26
Packaging and Labeling
Figure 25: Drawing for Vero SE 29 Packaging Tray
Notes for Figure 25:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
27
Packaging and Labeling
Figure 26: Vero SE Series Packaging and Labeling
Notes for Figure 26:
1. Each tray holds 50 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 27: Vero SE Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E10K0C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin
definitions.
28
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales
representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN121 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
29
About Bridgelux: We Build Light That Transforms
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538
Tel (925) 583-8400
www.bridgelux.com
© 2016-2017 Bridgelux, Inc. All rights reserved 2016. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are
registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Vero SE 29 Array Series Product Data Sheet DS123 Rev. F (6/2017)
30
Similar pages